Endress+hauser CLS82E Digital 4-electrode conductivity sensor Memosens

SKU: 4695814-1-1035-542
In Stock

  • Broad hygienic conductivity range
  • Memosens 2.0 digital technology
  • FDA, EHEDG, 3-A certified
  • Compact, sterilizable design

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Endress+hauser CLS82E Digital 4-electrode conductivity sensor Memosens

The Endress+Hauser Memosens CLS82E is engineered as a premium, hygienic conductivity sensor designed for applications where managing widely varying conductivity values is paramount. This advanced sensor ensures reliable monitoring of critical core processes, as well as final rinse stages, using just a single device. Its FDA compliance and compact, streamlined design guarantee a seamless integration into your specific processes. By leveraging the Memosens 2.0 digital technology, the CLS82E facilitates extended storage of both process and sensor data. This capability is invaluable for simplified lab calibration, predictive maintenance strategies, and establishing a robust foundation for advanced Industrial Internet of Things (IIoT) services, ensuring your operations are both efficient and future-ready.

Specific Applications For Wide Range Monitoring

The Memosens CLS82E excels in applications requiring the monitoring of diverse conductivity ranges, making it exceptionally versatile. It is ideally suited for Phase separation processes, where precise conductivity measurement can distinguish between different liquid phases. In Downstream processing and Fermentation, it ensures optimal conditions are maintained by accurately tracking conductivity changes throughout the biological or chemical processes. For Chromatography applications, the CLS82E provides the sensitivity needed to monitor eluent conductivity accurately. Its utility extends to Ultrafiltration processes, and it is particularly valuable for Final rinse stages in pharmaceutical applications, where ensuring the complete removal of cleaning agents requires highly sensitive conductivity measurements to meet stringent purity standards.

Hazardous Area Use With Advanced Certifications

Operating in demanding industrial environments, the Memosens CLS82E is designed with safety and compliance at its forefront. It boasts international explosion protection approvals, including ATEX, FM, CSA, and NEPSI, making it suitable for use in hazardous areas where flammable substances may be present. These certifications underscore the sensor’s robust design and its capability to prevent ignition in potentially explosive atmospheres. This makes the CLS82E a secure and reliable choice for critical applications in industries such as pharmaceuticals, biotechnology, and chemical processing, where maintaining process integrity and ensuring personnel safety are non-negotiable priorities, even in the most challenging conditions.

Hygienic Design For Maximum Purity Assurance

The Memosens CLS82E stands out with its exceptional hygienic design and materials, which are certified and approved by leading industry bodies such as EHEDG, 3-A, and FDA. This ensures strict compliance with Good Manufacturing Practice (GMP) requirements, making it perfectly suited for sensitive applications in the pharmaceutical and food and beverage industries. The sensor is not only designed for easy cleaning but is also sterilizable and autoclavable, allowing it to withstand rigorous cleaning protocols without compromising its performance or integrity. This focus on hygiene is critical for preventing contamination and maintaining the purity of products, especially in processes like fermentation or final rinsing, where the highest standards of cleanliness are absolutely essential.

Broad Measuring Range Saves Costs

One of the most significant advantages of the Memosens CLS82E is its broad measuring range, spanning from 1 µS/cm to an impressive 500 mS/cm. This expansive range means that a single CLS82E sensor can effectively monitor processes that previously required multiple sensors with different ranges, such as core process monitoring and final rinsing stages. This capability leads to substantial cost savings by reducing the need for additional instrumentation, simplifying installation, and streamlining maintenance. The ability to use one sensor for diverse conductivity levels within hygienic applications not only cuts down on capital expenditure but also simplifies inventory management and operational complexity, enhancing overall efficiency.

Memosens 2.0: Future-Proofing Your Operations

The integration of Memosens 2.0 digital technology into the CLS82E elevates its performance and future-proofs your operations. This advanced system allows for the extended storage of process and sensor data, which is crucial for detailed lab calibration and the implementation of predictive maintenance strategies. By capturing and retaining more data, users can gain deeper insights into process trends, enabling proactive issue identification and optimization. Furthermore, this robust data management capability provides the perfect foundation for enhanced IIoT services, allowing for seamless integration into smart manufacturing ecosystems, driving greater automation, efficiency, and data-driven decision-making across your facility.

Specifications

  • Measuring principle

    Conductive

  • Application

    Phase seperation, chromotography, fermentation
    CIP monitoring in small pipes
    Ultrafiltration
    Final rinse

  • Characteristic

    Conductivity sensor with a broad measurement range for all hygienic applications with advanced requirements to process safety

  • Measuring range

    1 µS/cm to 500 mS/cm

  • Measuring principle

    Hygienic 4-electrode conductivity sensor

  • Design

    Certified hygienic design with FDA compliant materials, 3-A and EHEDG certified, available as 120 mm sensor with PG13.5 and in many other standard process connections

  • Material

    Process connection: stainless steel 1.4435 (316L)
    Sensor element: platinum and ceramic

  • Dimension

    Sensor diameter: 12 mm (0.47 inch)
    Electrode length: depending on process connection

  • Process temperature

    -5 to 120 °C (23 to 248 °F)
    Sterilization: max. 140 °C at 6 bar for max. 45 min
    (Max. 284 °F at 87 psi for max. 45 min)

  • Process pressure

    17 bar abs at 20 °C (247 psi at 68 °F)
    9 bar abs at 120 °C (131 psi at 248 °F)

  • Temperature sensor

    Pt1000

  • Ex certification

    ATEX, NEPSI, CSA, IECE, EAC Ex, INMETRO

  • Connection

    Clamp 1,5″, Clamp 2″, Varivent F DN25,Varivent N DN40-DN125, BioControl DN25, PG13,5, DN25 standard/40mm, DN25 B.Braun port/65mm, Threat G1″, Thread NPT 1″
    Sensor connection: Inductive, digital connection head with Memosens 2.0 technology

  • Ingress protection

    IP 68 / NEMA Type 6P

  • Additional certifications

    Material certification 3.1
    3-A and EHEDG certified, hygienic design
    ASME BPE
    Conformity to cGMP derived requirements
    ASME BPE
    FDA approved
    Regulation (EC) No. 1935/2004
    China Food

Data Sheet

Download Data Sheet Of: Endress+hauser CLS82E Digital 4-electrode conductivity sensor Memosens