Hanna HI739 High Range Fluoride Colorimeter – Checker® HC
- Range: 0.0 to 20.0 ppm
- Resolution: 0.1 ppm
- Accuracy: of reading
- Light Source: LED at 575 nm
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
The Hanna HI739 Checker® HC is a powerful and precise tool designed to simplify the process of measuring fluoride levels, particularly in drinking water. This handheld colorimeter offers a significant upgrade from traditional chemical test kits, which often rely on subjective color matching and can lead to inaccuracies. By providing direct digital readings, the HI739 eliminates the guesswork and human error associated with visual comparisons. Its compact, one-button design makes it exceptionally user-friendly and portable, ensuring that accurate results are always just a few simple steps away. Whether for home use, environmental monitoring, or industrial applications, the HI739 provides a reliable and cost-effective method for water quality analysis.
The device’s functionality is rooted in an adaptation of the SPADNS method, a well-established procedure for the examination of water and wastewater. This ensures that the measurements are not only easy to obtain but also scientifically sound and consistent. With its small size and convenient design, the HI739 is easily carried in a pocket, making it ideal for on-the-go testing. The large LCD screen displays the concentration in parts per million (ppm), providing clear and unambiguous results. Additionally, an auto shut-off feature helps conserve battery life, ensuring the instrument is ready for use whenever needed. The HI739’s combination of advanced technology, ease of use, and portability makes it an indispensable tool for anyone concerned with fluoride levels in water.
Unveiling the Technology Behind Precise Readings
The core of the HI739’s precision lies in its use of a Light Emitting Diode (LED) as a light source and a silicon photocell as a light detector. This specific pairing, calibrated at a wavelength of 575 nm, allows the device to accurately measure the light absorption of the water sample after the reagents have been added. This method is far more reliable than the human eye, which can be easily deceived by lighting conditions or personal perception. When the cuvette is placed in the checker, the instrument performs a precise light measurement, converting the absorbed light into a digital concentration reading. This process, which is an adaptation of the Standard Methods for the Examination of Water and Wastewater, ensures high accuracy and reproducibility of results.
To further enhance measurement accuracy, the HI739 features clear prompts and a simple operating procedure. The user is guided through the process, from preparing the blank sample to adding the reagent and finally taking the measurement. The display shows helpful messages like “Add” and “Press” to indicate the next step. This streamlined approach minimizes the chance of user error and ensures consistent results every time. The instrument even provides warning messages and error codes to alert the user to potential issues, such as low light or an inverted cuvette, providing guidance on how to correct them.
A Comprehensive Guide to Operation and Maintenance
Operating the Hanna HI739 is a straightforward process, thanks to its one-button control system. The process begins with pressing the ON/OFF button to power on the device. The instrument then prompts the user to add the first reagent to a cuvette to create a blank, or zero, sample. After mixing and inserting the cuvette, the user can press and hold the button for a countdown, or wait a minute and then press the button to perform the zeroing. Once the checker is zeroed, the user is prompted to remove the cuvette and add a specific amount of the water sample.
After the sample is added and the cuvette is re-inserted, another press and hold of the button initiates the final measurement countdown. At the end of the timer, the checker performs the reading and displays the fluoride concentration. The entire process is designed to be quick and efficient, providing results in just a few minutes. Proper maintenance is key to the device’s longevity and accuracy. The user is advised to thoroughly wipe the cuvette with a lint-free cloth to remove fingerprints, dirt, or oil before each measurement. This simple step ensures that the light path is clear, preventing inaccurate readings.
Ensuring Accuracy: Tips and Troubleshooting
For consistently accurate results with the HI739, it’s essential to follow a few key best practices. First, the sample must be free of any debris that could interfere with the measurement. As mentioned, the cuvette must be dry and clean on the outside to prevent any light interference. Shaking the cuvette can create air bubbles, which can lead to higher readings, so it’s recommended to remove them by swirling or gently tapping the cuvette. To maintain accuracy, the reacted sample should not be allowed to stand for too long after the reagent has been added. Additionally, it’s crucial to discard the sample immediately after a reading to prevent permanent staining of the glass cuvette.
The HI739 is equipped with several error and warning messages to help users troubleshoot issues. For example, “Light High” or “L.H.” indicates that too much ambient light is reaching the detector, which could be due to a dirty cuvette. Conversely, “Light Low” or “L.Lo” means there isn’t enough light for a measurement. The “Inu” message alerts the user that the cuvettes have been inverted. If a blinking “0.0” appears, the sample is absorbing less light than the zero reference, and the user should check the procedure. A blinking maximum value indicates an “Over Range” condition, meaning the concentration is beyond the method’s limits and the sample should be diluted. These features ensure that the user can quickly identify and resolve problems.
Battery and Warranty Information
The HI739 operates on a single 1.5V AAA Alkaline battery, which provides a long operational life. A single fresh battery can last for a minimum of 5000 measurements. To extend battery life, the device has an auto shut-off feature that powers it down after 10 minutes of non-use and 2 minutes after a reading. This intelligent design ensures that the battery is not drained unnecessarily. When the battery is low, the instrument displays a “bAt” warning message before turning off. To replace the battery, the user simply needs to turn the instrument upside down, unscrew the cover, and insert a new AAA battery with the negative end first. Hanna Instruments provides a one-year warranty on the HI739 Checker HC, covering defects in workmanship and materials when the product is used for its intended purpose and maintained according to the instructions. This warranty is limited to repair or replacement free of charge. It is important to note that damage from accidents, misuse, tampering, or lack of proper maintenance is not covered. In the event of required service, customers are advised to contact their local Hanna Instruments Office. For any returns, a Returned Goods Authorization (RGA) number must first be obtained from the Technical Service department. This comprehensive support system ensures that users can rely on their device and receive assistance if any issues arise.
The Importance and Applications of Fluoride Testing
Fluoride is a naturally occurring element that, at certain concentrations, has a significant impact on human health. Its most well-known beneficial effect is the reduction of tooth decay, which is why many public water supplies practice water fluoridation. The World Health Organization (WHO) recommends a fluoride level of 0.5 to 1.0 mg/L depending on climate. However, excessive exposure to fluoride, especially when combined with other sources, can lead to adverse health effects. Therefore, accurate monitoring of fluoride levels is crucial for ensuring public health and safety.
The Hanna HI739 is specifically designed to address this need, providing an easy and accurate way to measure fluoride in drinking water. Its applications extend beyond public water systems to include drinking water treatment plants, bottled water production, and environmental monitoring. Since some domestic water filters can remove fluoride, the HI739 is also an excellent tool for home users who want to verify the fluoride content of their tap water after filtration. For industrial settings, it can be used to ensure water quality in various processes. The dedicated single-parameter design of the HI739 ensures that it is fine-tuned for this specific measurement, making it highly reliable for its intended applications.
The Global Excellence of Hanna Instruments and TPT24
Hanna Instruments is a globally recognized manufacturer known for producing high-quality and reliable analytical instruments. The HI739 is a testament to their commitment to providing advanced technology in a user-friendly format. All Hanna Instruments, including the HI739, conform to CE European Directives and are RoHS compliant, ensuring they meet strict quality and environmental standards. The company also emphasizes responsible disposal of electrical and electronic equipment and batteries, promoting recycling and environmental conservation.
For customers worldwide, TPT24 online store stands out as the premier online retailer for this product. TPT24 offers the HI739 with an assurance of authenticity and quality, delivering the product to customers in any country. Their commitment to excellence ensures that customers receive a genuine Hanna Instruments product backed by reliable service. By choosing to purchase the HI739 from TPT24, customers can be confident in the authenticity and quality of their purchase, knowing they are getting a top-tier instrument for their water testing needs.
Technical Specifications of the HI739
The Hanna HI739 is engineered with precise specifications to deliver accurate and reliable measurements. With a measurement range of 0.0 to 20.0 ppm, it can effectively test a wide spectrum of fluoride concentrations. The device has a high resolution of 0.1 ppm, allowing it to detect even small changes in concentration. Its accuracy is rated at of reading at 25°C, ensuring dependable results. The HI739 also features a compact and lightweight design, with dimensions of 86.0 x 61.0 x 37.5 mm and a weight of just 64 g, making it exceptionally portable. This combination of technical prowess and practical design makes the HI739 a superior choice for fluoride testing.
The device’s technical specifications include a silicon photocell light detector and a 575 nm LED light source, which are crucial for its colorimetric measurement method. The HI739 is designed to operate in an environment with a temperature range of 0 to 50°C and a maximum 95% RH non-condensing humidity. It runs on a single 1.5V AAA Alkaline battery, which offers a long life of at least 5000 measurements. The auto shut-off feature, which activates after 10 minutes of non-use, further enhances the product’s efficiency and battery conservation. These technical details collectively highlight the HI739 as a well-engineered and reliable instrument.
Features and Benefits of the HI739
The Hanna HI739 Checker HC is a practical and convenient device that offers several advantages over traditional methods. Its primary benefit is providing more accurate results than standard chemical test kits. By eliminating the need to match colors visually, it delivers direct digital readings, which significantly improves reliability. The one-button operation simplifies the testing process, making it accessible to a wide range of users, from professionals to home enthusiasts. The device is also dedicated to a single parameter, ensuring its design is optimized for the specific task of measuring fluoride. This focus allows for greater accuracy and reliability.
The compact and portable design of the HI739 makes it a great convenience. It can be easily carried in a pocket, allowing for quick testing anywhere. The large LCD screen ensures that the readings are clear and easy to see. The device also comes with a starter kit that includes reagents for 15 tests, cuvettes, and a battery, providing everything needed to get started right away. Its use is not only ideal for drinking water but also for environmental and industrial applications, making it a versatile tool. The HI739’s blend of user-friendliness, accuracy, and portability makes it a standout product in its category.
Specifications