Endress+hauser CCS51E Digital free chlorine sensor Memosens
- Measures free chlorine accurately
- Fast response time (t90 < 25 s)
- Memosens 2.0 technology
- Low maintenance design
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser CCS51E: Precise Free Chlorine Monitoring
The Endress+Hauser CCS51E Memosens sensor is engineered to deliver precise and consistent monitoring of free chlorine, a critical parameter for disinfection across various water applications. It is ideally suited for drinking water, swimming pool water, process water, and utilities. This advanced sensor boasts exceptionally fast response times, even when dealing with low water volumes, which is crucial for accurate process control and ensuring the safety of operations. Leveraging the power of Memosens 2.0 technology, the CCS51E combines maximum process and data integrity with a user-friendly interface. This robust foundation supports predictive maintenance strategies and seamless integration with Industrial Internet of Things (IIoT) connectivity, paving the way for smarter water management.
Securing Disinfection Across Water Applications
The CCS51E sensor is a versatile tool for maintaining disinfection efficacy in a wide array of water qualities. In drinking water systems, it plays a vital role in securing adequate disinfection levels, ensuring that water is safe for consumption and free from harmful pathogens. For utilities, it accurately detects the presence of free chlorine, allowing for timely adjustments to prevent any potential damage to infrastructure or processes that might be caused by incorrect chlorine levels. In food processing, it guarantees hygienic conditions for packaging and bottling by ensuring proper free chlorine levels in the process water, thereby safeguarding product safety and quality.
Efficient Process Control with Rapid Response
A key advantage of the Endress+Hauser CCS51E is its remarkably fast response time, with a t90 (time to reach 90% of the final reading) of less than 25 seconds. This rapid performance provides operators with an accurate, real-time view of the free chlorine concentration in the process. Such immediate feedback enables prompt reactions to any changes or fluctuations in the water chemistry, leading to highly efficient process control. This responsiveness is essential for optimizing disinfection dosages, ensuring that the right amount of chlorine is used, neither too little to be ineffective nor too much to be wasteful or harmful.
Minimizing Costs with Low-Maintenance Design
The CCS51E is designed as a low-maintenance, amperometric sensor, which significantly reduces the overall cost of ownership for the measuring point. This is particularly advantageous when compared to older, more maintenance-intensive systems, such as colorimetric measuring systems. The durable construction and reliable performance of the CCS51E mean less frequent servicing and fewer consumables. Combined with the ease of sensor exchange enabled by Memosens 2.0 technology, this sensor helps to maximize process up-time, making it a highly economical and efficient choice for continuous monitoring applications.
Achieving High Process Safety and Dosing Efficiency
The high process safety and efficiency in dosing offered by the CCS51E are direct results of its precise and long-term stable measurement capabilities. By consistently monitoring free chlorine levels, the sensor ensures that disinfection processes remain within the desired parameters. This reliability allows for individually adapted disinfectant dosing strategies, meaning that the exact amount of disinfectant required can be precisely administered. This not only enhances safety by ensuring adequate disinfection but also optimizes chemical usage, leading to cost savings and a reduced environmental footprint.
Tailored Sensor Versions for Every Range
The Endress+Hauser CCS51E sensor is available in multiple versions, each tailored to specific measurement ranges, providing optimal performance across diverse applications. Whether you need to monitor trace amounts of free chlorine or measure concentrations as high as 200 mg/l, there is a suitable sensor configuration. The available ranges are: Trace (0 to 5 mg/l HOCl), Standard (0 to 20 mg/l HOCl), and High (0 to 200 mg/l HOCl). This flexibility ensures that the sensor is always operating within its optimal performance window, delivering accurate and reliable data regardless of the chlorine concentration.
Seamless Integration for Comprehensive Analysis
The CCS51E is designed for easy integration into existing water quality monitoring systems. Its Memosens connection allows for straightforward combination with other relevant liquid analysis parameters when used with the versatile Liquiline multiparameter transmitter. This capability enables users to simultaneously monitor free chlorine alongside other critical parameters, such as pH and ORP (Oxidation-Reduction Potential). By consolidating data from multiple sensors onto a single platform, operators gain a more holistic view of water quality, simplifying analysis, improving operational insights, and facilitating more effective overall water management strategies.
Your Global Partner: Trust tpt24 for Excellence
For reliable, high-performance free chlorine monitoring, Endress+Hauser’s CCS51E Memosens sensor is the industry standard, and tpt24 is your premier global source for this essential technology. As the world’s leading online store for this product, tpt24 is committed to delivering not just the sensor, but also the assurance of genuine authenticity and uncompromising quality, delivered directly to your location anywhere in the world. We understand the critical nature of water quality monitoring and strive to provide our customers with the best products backed by unparalleled service and global delivery. Choose tpt24 for your Endress+Hauser needs and experience the pinnacle of quality and reliability.
Specifications
-
Measuring principle
Free chlorine
-
Application
Ensuring reliable disinfection in drinking water
Process water
Dosing disinfectant efficiently in pool water
Detect the absence or presence of free chlorine in Utilities
Guarantee food safety and provide hygienic packaging and bottling -
Characteristic
Amperometric measurement of dissolved free chlorine
-
Measuring range
Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl
High: 0 to 200 mg/l HOCl -
Measuring method
Closed, membrane covered measuring cell
Reduction of free chlorine at the cathode -
Design
Closed amperometric 2-electrode measuring cell with PVDF membrane
-
Material
Sensor shaft: POM
Membrane: PVDF
Membrane cap: PVDF
Sealing ring: FKM -
Dimension
Diameter: 25 mm (0.98 inch)
Length: 161 mm (6.34 inch) -
Process temperature
0 to 55 °C (32 to 130 °F), non-freezing
-
Process pressure
Max. 1 bar (max. 14.5 psi)
-
Temperature sensor
10k NTC integrated (Memosens)
-
Connection
Inductive, digital connection head with Memosens