- Home
- Instrumentation
- Flow measurement
- Coriolis mass flowmeters
- Endress+hauser F 200 Proline Promass Coriolis flowmeter
Endress+hauser F 200 Proline Promass Coriolis flowmeter
- Endress+Hauser Promass F 200 two-wire Coriolis flowmeter for precise mass flow, density, and temperature.
- Intrinsically safe Ex ia design and global approvals for hazardous areas and SIL-rated applications.
- Loop-powered architecture simplifies wiring; no in-/outlet runs required for space-limited installs.
- Heartbeat Technology enables continuous diagnostics and traceable verification without process interruption.
- Handles media up to +205 °C and offers DN 8 to DN 80 (3/8″ to 3″) line sizes.
- Supported by technical consultation and quotation assistance from TPT24 at tpt24.com.
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser Promass F 200 overview
Endress+Hauser Promass F 200 brings two‑wire Coriolis performance to mainstream process applications, combining proven F‑series accuracy with simplified integration. The instrument is designed for safe, reliable operation in hazardous locations while reducing wiring complexity and panel load. From day one, plants achieve measurable gains in accuracy, uptime, and lifecycle efficiency.
Engineered on the Coriolis principle, the meter measures mass flow, volume flow, density, and temperature independently of viscosity, conductivity, or fluid profile. Therefore, stable results are obtained for liquids and gases even when media properties fluctuate. This multivariable capability consolidates instrumentation, reduces potential leak paths, and improves overall process control.
Key benefits of Endress+Hauser Promass F 200
As a loop‑powered device, Endress+Hauser Promass F 200 minimizes installation effort and eliminates auxiliary power supplies. The intrinsically safe Ex ia concept supports safe deployment in volatile atmospheres and aligns with global hazardous area schemes. Moreover, Heartbeat Technology provides continuous self‑monitoring and documented verification to extend calibration intervals.
The instrument’s compact sensor requires no straight inlet or outlet runs, enabling placement near valves and elbows. Consequently, brownfield plants and compact skids can adopt high‑accuracy Coriolis measurement without major piping changes. With DN 8 to DN 80 coverage and high medium temperature capability up to +205 °C, diverse duties are supported with one platform.
Technical highlights and metrological integrity
Endress+Hauser Promass F 200 achieves typical mass flow accuracy up to ±0.1% for liquids, delivering dependable results in dosing, blending, and transfer. The dual‑compartment housing segregates electronics and terminals for robustness and serviceability. A touch‑controlled, backlit display permits safe local operation without opening the enclosure.
In parallel, the separate connection compartment simplifies loop terminations and maintenance. Digital integration is seamless via widely used protocols within the two‑wire ecosystem. Together, these features strengthen measurement traceability and reduce lifecycle cost of ownership across regulated industries.
Typical applications and industries for Endress+Hauser Promass F 200
In chemical processing, precise mass dosing of corrosives and solvents is supported with consistent accuracy. Oil and gas facilities deploy the meter for additive injection, fuel measurement, and hydrocarbon transfer in classified areas. Pharmaceutical and biotech users benefit from hygienic variants and verification workflows that align with quality frameworks.
Food and beverage plants leverage the meter’s stability to maintain recipe ratios and batch repeatability. Additionally, the ability to measure gases expands its utility in utilities, inerting, and process analytics. Across each sector, the instrument’s immunity to changing fluid properties safeguards product quality and throughput.
Installation, integration, and safety advantages
Endress+Hauser Promass F 200 reduces engineering time through two‑wire, loop‑powered simplicity and clear terminal segregation. The absence of straight run requirements eases placement on dense skids and retrofits. Furthermore, Ex ia intrinsic safety and SIL suitability support risk reduction in safety‑relevant functions when engineered per standards.
Heartbeat Technology offers on‑demand verification and continuous diagnostics, supporting predictive maintenance. This approach minimizes unscheduled downtime while providing audit‑ready documentation for quality systems and compliance reviews.
Why Buy from TPT24
TPT24 is a specialist supplier of instrumentation and measurement equipment, providing genuine Endress+Hauser products backed by technical consultation and quotation support. Through tpt24.com, engineering teams receive application‑driven guidance on sizing, metallurgy, and integration to ensure the correct configuration for plant objectives. Our goal is to streamline selection and procurement while maintaining measurement integrity and operational reliability.
Conclusion and next steps with Endress+Hauser Promass F 200
Endress+Hauser Promass F 200 unites two‑wire efficiency, Ex ia safety, and Heartbeat verification to elevate process performance. For compliant accuracy across liquids and gases, it is a compelling choice for new builds and retrofits alike. To specify Endress+Hauser Promass F 200 for your project, request expert guidance and a formal quote at tpt24.com today.
Specifications
| Specification | Details |
|---|---|
| Measuring principle | Coriolis |
| Product headline | Robust flowmeter with genuine loop-powered technology. Highest measurement performance for liquids and gases in a wide range of applications. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Mass flow: measured error ±0.1 %. Medium temperature up to +205 °C (+401 °F). Nominal diameter: DN 8 to 80 (³⁄₈ to 3″). |
| Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). |
| Nominal diameter range | DN 8 to 80 (⅜ to 3″) |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404; Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
| Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +150 °C (–58 to +302 °F) Option: –50 to +205 °C (–58 to +401 °F) |
| Ambient temperature range | –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | AlSi10Mg, coated, 1.4404 (316L) |
| Degree of protection | IP66/67, type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
| Outputs | 4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive) |
| Inputs | None |
| Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Power supply | DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch) DC 18 to 30 V (20 mA HART, 4‐20 mA) DC 9 to 32 V (PROFIBUS PA) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex |
| Product safety | CE, C-TICK |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |








