0
0 items
$0.00
No products in the cart.
- High current output: up to 1800A
- Digital memory ammeter included
- Multi-range, crystal-controlled timer
- Solid-state output initiate circuit
- Temperature Range: -32°C to 1050°C
- Distance to Spot: 20:1 Ratio
- Adjustable Emissivity: 0.10~1.0
- Response Time: 250ms
- Temperature Range: -32°C to 650°C
- Distance to Spot: 20:1 Ratio
- Adjustable Emissivity: 0.10~1.0
- Fast Response Time: 250ms
- Temperature Range: -32°C to 450°C
- Distance to Spot: 20:1 Ratio
- Adjustable Emissivity: 0.10~1.0
- Response Time: 250ms (95% reading)
- Temperature Range: -32°C to 1250°C
- Distance to Spot: 30:1 Ratio
- Adjustable Emissivity: 0.10~1.0
- Response Time: 250ms (95% reading)
- Temperature Range: -32°C to 1050°C
- Distance to Spot: 30:1 Ratio
- Emissivity: 0.10~1.0 Adjustable
- Response Time: 250ms Fast Reading
- Temperature Range: -32°C to 650°C
- Distance to Spot: 30:1 Ratio
- Emissivity: 0.10~1.0 Adjustable
- Response Time: 250ms Fast Reading
- AutoVolt AC/DC Voltage Detection
- True-RMS Accurate Measurements
- Prevents Ghost Voltage Errors
- Compact One-Handed Operation
- IP67: Dustproof and Waterproof
- Measures Up to 1000V
- Withstands 3-Meter Drops
- CAT IV/CAT III Certified
- Temperature Range: -50°C to 1050°C
- D:S Ratio: 50:1 Long Range
- Data Storage: 99 Sets Capacity
- Emissivity: Adjustable 0.1 to 1.0
- AC Current: Up to 3000A
- True RMS: Accurate, complex waveforms
- Flex Coil: 18-inch flexible probe
- Durability: 2-meter drop-proof
- AC Current: Up to 3000A
- True RMS: Accurate non-sinusoidal AC
- Flex Coil: 18-inch flexible probe
- Durability: IP54, 2m drop-proof
- AC Current: Up to 3000A
- True RMS: Accurate non-sinusoidal AC
- Flex Coil: 18-inch flexible probe
- Durability: IP54, 2m drop-proof
- 30:1 Distance-to-Spot Ratio
- 1300°C Max IR Temperature
- Type K Thermocouple Included
- 99 Readings Data Storage
Recently Viewed Products
- Accuracy: ±0.05 °C Conversion Precision
- Inputs: Up to Sixteen RTDs
- Protocol: FOUNDATION™ Fieldbus Communication
- Range: −200 to 250 °C
krohne SU 502
In Stock
- Single-channel vibration level controller
- Powers KROHNE limit switches
- SIL 2/3 certified
- DIN rail mounting
- ORP range 0 to 1000 mV
- Accuracy ±5 mV at 25°C
- Dosing relay max 2A load
- Input impedance 10^12 Ohm
- Movement Accuracy: Plus-minus 2 mm
- Maximum Range: 50 meters
- Alarm Volume: 105 decibels
- Standard Run Time: 6 hours
- Measurement Type: Clamp-on Ultrasonic
- Installation: Permanent, no pipe cutting
- Pipe Range: DN15 to DN4000
- Temperature: Up to +200°C
Join our newsletter for £10 offs
Get our emails for info on new items, sales and much more.
Register now to get latest updates on promotions & coupons. Don’t worry, we not spam!

Industrial Instrumentation Supplier
Fair Pricing, Guarantee of Authenticity and Quality, Fast Delivery, and Provision of Technical Support to Customers.
Need Help?
Customer Service
Store Information
- -5% for all order in this week Shop now
- Free delivery for all orders over $200