Endress+hauser CCS50E Digital chlorine dioxide sensor Memosens

In Stock

  • Chlorine dioxide measurement
  • Memosens 2.0 technology
  • Wide measuring range
  • Fast response time

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Endress+Hauser CCS50E: Chlorine Dioxide Measurement Simplified

The Endress+Hauser CCS50E Memosens sensor offers a straightforward and robust solution for measuring chlorine dioxide, designed for low-maintenance operation across a variety of demanding applications. This advanced sensor delivers fast and stable readings, making it ideal for use in utilities, drinking water treatment, and various process water applications. Its primary role is to ensure efficient disinfection processes, thereby guaranteeing the highest standards of water quality and safety. Crucially, it also helps to prevent the critical issue of chlorine dioxide overdosing, which can be detrimental to both processes and safety. The CCS50E is equally effective in monitoring the absence of chlorine dioxide in sensitive environments such as beverage plants and reverse osmosis systems, providing comprehensive process control.

Ensuring Water Quality and Safety Standards

The CCS50E sensor plays a pivotal role in maintaining critical water quality and safety standards across multiple sectors. In drinking water applications, it ensures that disinfection levels are adequate, providing assurance that harmful pathogens are effectively neutralized, thus safeguarding public health. For cooling water systems and towers, the sensor is vital in preventing the proliferation of dangerous pathogens like Legionella, contributing to safer operational environments. It is also extensively used in process water for the food and beverage industry, particularly for water used in washing pre-packaged vegetables, ensuring hygienic conditions for food safety throughout the packaging and bottling processes.

Optimizing Disinfection with Precise Measurement

The ability of the CCS50E to provide fast response times is a key benefit, offering an accurate, real-time view of the chlorine dioxide concentration in your process. This immediate feedback allows for prompt reactions to any process changes or deviations, enabling highly efficient process control. By maintaining precise and long-term stable measurements, the sensor contributes to increased process safety. It ensures consistent process monitoring, allowing operators to maintain the lowest effective disinfectant concentration required, thereby optimizing chemical usage, reducing costs, and minimizing potential negative impacts on equipment or products.

Seamless Integration and Operation with Memosens

A significant advantage of the CCS50E is its seamless integration with the Memosens 2.0 technology. This digital connection head facilitates not only a faster polarization time for the sensor but also ensures maximum data integrity and simple, intuitive operation. The Memosens system allows for pre-calibration of the sensor in a laboratory environment, enabling a quick and easy plug-and-play sensor exchange directly in the process. This dramatically increases process up-time, as downtime for sensor maintenance or calibration is minimized, allowing operations to continue with minimal interruption.

Versatile Applications for Various Water Types

The versatility of the Endress+Hauser CCS50E extends to its suitability for a range of water types and specific applications. In beverage and reverse osmosis plants, it is instrumental in confirming the absence of chlorine dioxide, a critical parameter for product integrity and process stability. Its wide measuring range, from trace levels up to 200 mg/l of chlorine dioxide, offers exceptional flexibility. This allows it to be used for sensitive measurements in processes where even small amounts of residual disinfectant must be detected, as well as in applications requiring higher concentrations for effective treatment, covering the full spectrum of chlorine dioxide monitoring needs.

Robust Design for Reliable Field Performance

The CCS50E features a robust, closed, membrane-covered amperometric measuring cell designed for longevity and reliable performance in demanding field conditions. The sensor shaft is constructed from POM (Polyoxymethylene), a durable and chemically resistant plastic, while the membrane and membrane cap are made from PVDF (Polyvinylidene Fluoride), known for its excellent resistance to chlorine dioxide and other aggressive chemicals. This careful selection of materials ensures that the sensor can withstand typical process environments, offering consistent and accurate measurements over extended periods with minimal maintenance required.

Designed for Ease of Installation and Connectivity

Installation of the CCS50E is designed to be straightforward and efficient, compatible with the modular Flowfit CYA27 assembly or other immersion assemblies. The inductive, digital connection provided by the Memosens technology simplifies the physical connection process, eliminating the need for direct wiring into the transmitter. Furthermore, the CCS50E can be easily combined with other relevant parameters of liquid analysis by connecting it to the versatile Liquiline multiparameter transmitter. This allows for a consolidated monitoring approach, where chlorine dioxide levels can be viewed alongside other critical parameters like pH, ORP, or conductivity on a single platform.

Your Trusted Source: tpt24 for Global Excellence

For industries worldwide relying on accurate and dependable chlorine dioxide measurements, tpt24 is your ultimate online destination. We are recognized as the foremost global online store for the Endress+Hauser CCS50E Memosens sensor, offering not only the product itself but also an unwavering guarantee of authenticity and superior quality. Our commitment extends to ensuring that every customer, regardless of their geographical location, receives their order reliably and efficiently. Choose tpt24 for your CCS50E needs and benefit from our dedication to providing top-tier instrumentation and exceptional customer service on a global scale.

Specifications

  • Measuring principle

    Chlorine dioxide

  • Application

    Adequate disinfection in drinking water, preventing of pathogen formation in cooling water systems, water used to wash pre-packaged vegetables, ensures the absence of chlorine dioxide in beverage systems

  • Characteristic

    Amperometric measurement of dissolved chlorine dioxide

  • Measuring range

    Trace: 0 to 5 mg/l ClO2
    Standard: 0 to 20 mg/l ClO2
    High: 0 to 200 mg/l ClO2

  • Measuring principle

    Closed, membrane covered measuring cell
    Reduction of chlordioxide (ClO2) to chloride at the cathode with appr. 120mV

  • Design

    Closed amperometric 2-electrode measuring cell with PVDF membrane

  • Material

    Sensor shaft: POM
    Membrane: PVDF
    Membrane cap: PVDF

  • Dimension

    Diameter: 25 mm (0.98 inch)
    Length: 161 mm (6.34 inch)

  • Process temperature

    0 to 55 °C , non-freezing
    (32 to 130 °F)

  • Process pressure

    Max. 2 bar abs
    (Max. 29 psi abs)

  • Temperature sensor

    10k NTC integrated (Memosens)

  • Connection

    Inductive, digital connection head with Memosens