Endress+hauser CLD132 Conductivity compact device Smartec
- Inductive measuring principle
- Ultrafast temperature response
- IP67 ingress protection
- Profibus communication included
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser CLD132: Precision Conductivity Control
The Endress+Hauser Smartec CLD132 stands as a compact, high-performance measuring system designed specifically for inductive conductivity applications. This integrated solution, combining a sophisticated transmitter and a robust sensor, delivers an interference-free and exceptionally user-friendly experience. A standout feature is its integrated stainless steel temperature sensor, engineered to provide an ultra-fast temperature response. This rapid response is critical for ensuring highly reliable and accurate measurements, particularly in dynamic separation applications where swift temperature changes can significantly impact conductivity readings. The CLD132 is built to offer consistent precision, making it an indispensable tool for a wide array of industrial processes that demand meticulous control and monitoring of liquid conductivity. Its design prioritizes operational efficiency and accuracy, ensuring that businesses can maintain optimal process conditions with confidence and minimal effort.
Swift Temperature Response for Reliability
A paramount benefit of the Endress+Hauser Smartec CLD132 is its meticulously engineered design for rapid temperature response. The inclusion of a high-quality stainless steel temperature sensor ensures that any fluctuations in process temperature are detected and compensated for almost instantaneously. This ultrafast response is vital in applications such as phase separation, where even slight temperature variations can alter conductivity values, potentially leading to inaccurate readings and compromised product quality. By providing real-time temperature compensation, the CLD132 guarantees that the conductivity measurements remain precise and dependable, regardless of transient thermal conditions. This capability directly translates into enhanced process control, reduced material waste, and improved overall product consistency, making it a critical asset for maintaining the highest standards in demanding industrial environments. The speed of response is a true game-changer.
Robust Inductive Sensor Resists Fouling
The Smartec CLD132 utilizes an inductive measuring principle, which offers significant advantages, particularly in applications where traditional conductive sensors might struggle. Its encapsulated sensor design inherently reduces the risk of soiling, as there are no electrodes in direct contact with the medium that could become coated or fouled. This design makes the CLD132 remarkably insensitive to polarization effects, ensuring stable and accurate measurements even in highly conductive or corrosive media. The PEEK material used for the sensor further enhances its resistance to chemical aggression and wear, prolonging its lifespan and reducing maintenance requirements. This robust construction ensures consistent performance and minimal drift over time, providing a reliable solution for challenging industrial environments where sensor cleanliness and longevity are paramount. The CLD132 truly embodies durability and performance.
Versatile Applications in Key Industries
The Endress+Hauser Smartec CLD132 is specifically tailored for a diverse range of crucial industrial applications, ensuring precise control and monitoring. It is particularly effective for alkaline/acid concentration control in remaking processes, allowing for accurate chemical dosing and cost efficiency. Its capability for phase separation of product/water and product/product mixtures in pipe systems is invaluable, minimizing waste and ensuring product purity. The system also excels in product monitoring in breweries, dairies, and the beverage industry, guaranteeing consistent quality and adherence to recipes. Furthermore, it is ideally suited for the monitoring and control of bottle cleaning systems, ensuring thorough sanitization while optimizing water and chemical usage. Its compact design and robust performance make it a go-to solution for critical applications requiring highly accurate and reliable conductivity measurements across various sectors.
Comprehensive Communication and Integration Options
The Endress+Hauser Smartec CLD132 is designed for seamless integration into existing control systems, offering a variety of standard protocols and interfaces. It supports the widely used 0/4…20mA analog output, ensuring compatibility with conventional control systems. For more advanced digital communication, it features HART protocol, which allows for remote configuration, diagnostics, and process variable transmission, significantly simplifying setup and troubleshooting. Furthermore, the CLD132 is equipped with PROFIBUS DP and PROFIBUS PA interfaces, providing robust and reliable digital communication options for complex fieldbus networks. These extensive communication capabilities ensure that the CLD132 can be easily incorporated into diverse automation architectures, enabling efficient data exchange and centralized control. This flexibility enhances its utility across a broad spectrum of industrial applications, guaranteeing connectivity.
Robust Design for Demanding Environments
The Smartec CLD132 boasts a robust and practical design, making it highly suitable for demanding industrial environments. The compact transmitter is crafted from high-quality polished stainless steel (1.4301), ensuring excellent corrosion resistance and durability. The sensor itself is made from PEEK, a material renowned for its chemical inertness and mechanical strength, further enhancing the system’s longevity. The transparent polycarbonate window provides clear visibility of the display. With an ingress protection rating of IP67, the CLD132 is well-protected against dust ingress and the effects of temporary immersion in water, making it suitable for washdown areas and challenging outdoor installations. The use of Chemraz for sealing components further ensures excellent chemical resistance, contributing to the system’s overall reliability and extended operational life even when exposed to harsh chemicals.
Wide Measuring Range and Pt100 Temperature Sensor
The Endress+Hauser Smartec CLD132 offers an impressive measuring range for inductive conductivity, spanning from 100 µS/cm up to a substantial 2000 mS/cm. This broad capability allows the system to accurately monitor a wide spectrum of liquid concentrations, from low-conductivity clean water to highly concentrated solutions. The integrated Pt100 temperature sensor is a critical component, providing highly accurate temperature compensation. This ensures that the conductivity readings are always precise and independent of temperature fluctuations, which is crucial for reliable process control. While the maximum process temperature is 140°C (284°F) for up to 30 minutes, and maximum process pressure is 12 bar (174 psi) at 90°C (194°F), the system’s ability to maintain accuracy across its wide measuring range and diverse temperature conditions makes it an incredibly versatile tool for many industrial applications.
Specifications
-
Measuring principle
Inductive
-
Application
– Alkali/acid concentration control – phase separation in pipe systems – monitoring and control of bottle cleaning systems – product monitoring in breweries, dairies and the beverage industry – CIP system control
-
Characteristic
Compact measuring system for an inductive conductivity measurement special made for media with a high conductivity.
-
Measuring range
100 µS/cm – 2000 mS/cm
-
Measuring principle
Inductive measuring system including transmitter and sensor.
-
Design
Compact transmitter made of stainless steel with an inductive sensor made of PEEK in a separate or compact version.
-
Material
Housing: Stainless steel 1.4301 polished Window: Polycarbonate Sensor: PEEK, stainless steel 1.4435 Sealing: Chemraz
-
Process temperature
max. 140°C (max. 30 min.)
284°F (max. 30 min.) -
Process pressure
max. 12 bar (90°C)
(174 psi(194°F)) -
Temperature sensor
Pt100
-
Ex certification
No
-
Ingress protection
IP67
-
Input
One-channel transmitter incl. temperature.
-
Output / communication
Conductivity and temperature 0/4-20 mA, HART, Profibus.