Endress+hauser CPA842 Process assembly Unifit

In Stock

  • Hygienic design meets standards
  • CIP/SIP compatible
  • Reduced residue build-up
  • Leak-tight electrode seal

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Endress+hauser CPA842 Process assembly Unifit

The Endress+Hauser Unifit CPA842 process assembly stands as a pinnacle of design, meticulously engineered to meet the most stringent requirements for inline cleaning and sterilization. This advanced assembly facilitates the seamless installation of essential sensors—including those for pH/ORP, oxygen, conductivity, and cell growth—into tanks and pipelines within hygienic and sterile application environments. The CPA842 is designed and manufactured in strict accordance with leading industry standards such as EHEDG, 3-A, ASME BPE, FDA, and USP Class VI, ensuring utmost safety, reliability, and compliance for critical processes across various sectors.

Food and Beverage: Ensuring Product Purity

In the food and beverage industry, maintaining product purity and preventing cross-contamination are of paramount importance. The Unifit CPA842 excels in these areas, offering a hygienic design that meets EHEDG Class I, 3-A standard 74-05, FDA, ASME BPE, and USP Class VI requirements. This ensures that no contaminants are introduced into the product stream. The leak-tight, built-in electrode seal further prevents contamination, while the electropolished surface (achieving Ra=0.38 µm or 0.76 µm) minimizes residue build-up. Its suitability for cleaning-in-place (CIP) and sterilization-in-place (SIP) makes it an indispensable component for maintaining the highest hygiene standards in food and beverage production.

Life Sciences: Sterile Applications Guaranteed

For the life sciences sector, where sterile conditions are non-negotiable, the Unifit CPA842 provides an exceptionally reliable solution for inline sensor installation. Its rigorous adherence to EHEDG, 3-A, FDA, and USP Class VI standards guarantees that it meets the demanding requirements of pharmaceutical, biotechnology, and medical applications. The assembly’s design prevents cross-contamination and minimizes residue build-up, which is critical for sensitive biological processes and drug manufacturing. Furthermore, its compatibility with CIP and SIP protocols ensures that the assembly can be effectively sterilized between batches, upholding the integrity of sterile operations.

Chemical Industry: Versatile Hygienic Measurement

Within the chemical industry, the Unifit CPA842 offers a versatile and robust solution for hygienic process monitoring. It allows for the permanent installation of various sensors, including those for pH, ORP, oxygen, and conductivity, in tanks and pipelines. Its construction from high-grade stainless steel (1.4404) and FDA-compliant, USP Class VI seals ensure compatibility with a wide range of chemicals. The assembly’s ability to withstand pressures of up to 16 bar at 140 °C makes it suitable for demanding chemical processes, while its hygienic design ensures that it meets stringent cleanliness standards, preventing contamination of the process medium.

Process Applications: Flexible and Reliable Monitoring

The Unifit CPA842 is designed for a broad spectrum of process applications where reliable inline measurement is essential. Whether in open or closed tanks, or within piping systems, this fixed installation assembly provides a secure and contamination-free platform for sensors. Its flexible adaptation to various hygienic process connections, including DN25 standard, B.Braun, various clamp sizes, and dairy fittings, ensures it can be integrated into almost any existing system. This adaptability, combined with its robust construction and hygienic design, makes it a dependable choice for continuous process monitoring.

Enhanced Cleanliness and Reduced Residues

A key advantage of the Unifit CPA842 is its focus on enhanced cleanliness and the reduction of residue build-up. The electropolished surface finish, available in Ra=0.38 µm or 0.76 µm, significantly minimizes areas where residues can adhere, simplifying cleaning processes and reducing the risk of microbial growth. This feature is particularly beneficial in hygienic applications where product integrity and sterility are critical. The leak-tight electrode seal further contributes to cleanliness by preventing any leakage of process media or cleaning agents, ensuring a more hygienic and efficient operation.

CIP/SIP Capabilities for Maximum Efficiency

The Unifit CPA842 is fully compatible with Cleaning-In-Place (CIP) and Sterilization-In-Place (SIP) procedures, which are vital for maintaining hygiene and operational efficiency in many industries. This capability allows for thorough cleaning and sterilization of the assembly and the installed sensor without requiring manual disassembly. By enabling automated and effective cleaning cycles, the CPA842 significantly reduces downtime, lowers labor costs, and ensures that the equipment is consistently ready for production. This feature is indispensable for applications in the food, beverage, and life sciences sectors.

Specifications

  • Measuring principle

    Potentiometric

  • Application

    Food & Beverage, Life Science, Process

  • Installation

    Fixed installation assembly

  • Characteristic

    Open and closed tank, piping

  • Design

    Hygienic assembly with corresponding process connections
    12 mm electrodes
    Optional with protection guard
    Optional with leakage control

  • Material

    Holder: stainless steel 1.4404
    Seals: EPDM, FKM, FFKM, all seals are FDA conform, USP Class VI

  • Dimension

    Immersion depth: 29.5 to 86.5 mm (1.16 to 3.4 inch)

  • Process temperature

    -15 to 140 °C (5 to 280 °F)

  • Process pressure

    16 bar up to 140 °C (232 psi up to 284 °F)

  • Connection

    DN25 standard, DN25 B.Braun, Clamp 1.5″ (short and long), Clamp 1.5” angled at 15°, Clamp 2″, Varivent flange N, dairy fitting DN50

Data Sheet