Endress+Hauser CPL51E Digital pH sensor Memosens

In Stock

  • Grab sample: On-site collected sample for analysis
  • Online loop: Continuous measurement pathway in a process
  • Potentiometric: Voltage-based sensor principle
  • Digital 2.0: Modern data protocol for sensor networks

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Endress+Hauser CPL51E Brochure

  1. Comprehensive induction of advanced field-ready sensing technology
    The CPL51E, a digital Memosens pH sensor, represents a robust fusion of precision chemistry and rugged field design. Engineered with a durable plastic shaft, this sensor is purpose-built for random sampling directly in the field or within laboratory environments. The cornerstone of its reliability is the contactless inductive Memosens cable connection, which ensures a signal and power transfer that remains insensitive to moisture and corrosion. This feature significantly reduces maintenance needs and prolongs sensor life in challenging water matrices. The CPL51E ships pre-calibrated and is ready for immediate use, helping minimize setup time and expedite data collection workflows. When paired with the mobile Liquiline Mobile CML18 handheld analyzer, the CPL51E integrates without requiring additional configuration, enabling rapid deployment in diverse field scenarios or on-site laboratory stations. In practice, this sensor is ideally suited for measurements in drinking water, wastewater, and process water. It serves a broad range of field operations, including the verification of online measuring loops, analysis of grab samples both on-site and in the laboratory, and pH measurement at process points where online measurement is not installed. The instrument’s field capability is complemented by laboratory versatility, making it a dependable choice for mixed environments and cross-functional teams.
  2. Key applications in drinking water and process control environments
    In drinking water applications, CPL51E facilitates the check of online measuring loops to ensure continuous process integrity and regulatory compliance. Its field-ready, pre-calibrated design makes it ideal for grab sampling, enabling accurate on-site assessments that feed into quality assurance programs. For wastewater and process water, CPL51E supports on-site sample analysis and in-lab testing, providing a flexible approach to monitor pH changes, detect deviations, and trigger timely process adjustments. The sensor’s potentiometric measuring principle offers stable, reliable readings across a wide pH spectrum, while its digital Memosens 2.0 technology delivers tamper-resistant data storage of serial numbers and calibration histories, a critical feature for traceability and quality management systems. The combination of robust physical construction, open-aperture reference, and automatic temperature compensation ensures consistent performance even in harsh environments or temperature-variable sampling sites. The ability to measure pH at process points without online measurement installations expands the operator’s capacity to validate process controls, confirm treatment efficiency, and optimize chemical dosing strategies. Moreover, the CPL51E’s glass-membrane protection, coupled with leak-resistant packaging, minimizes risk during transport and handling in field conditions. The sensor supports laboratory workflows by delivering repeatable measurements when sample integrity is preserved, contributing to reproducible results across multiple testing modalities and teams.
  3. Design features emphasizing durability and measurement integrity
    The Endress+Hauser CPL51E employs a robust plastic shaft that withstands field handling and handling during routine sampling. Its Memosens inductive connection provides a moisture- and corrosion-insensitive interface, a critical design attribute for consistent data collection in damp or aqueous environments. The glass membrane, safeguarded by a physical protective barrier, remains shielded in both laboratory benches and field sampling kits, reducing susceptibility to breakage and damage. An integrated temperature sensor delivers automatic temperature compensation, maintaining accuracy when process temperatures vary. The sensor demonstrates fast response times even in ion-weak water, ensuring rapid and actionable readings. The open-aperture reference minimizes clogging risk, a frequent concern with traditional glass-based references. The digital Memosens 2.0 protocol supports calibration history and serial-number storage, enabling robust quality management and audit readiness as part of compliant production or water treatment practices. The CPL51E is designed for compatibility with laboratory workflows and field checks, bridging the gap between in-situ monitoring and controlled laboratory analysis. The instrument’s IP68 ingress protection rating denotes a high degree of environmental sealing, enabling immersion up to deep submersion in water during cleaning routines or field sampling events.
  4. Detailed specifications and performance characteristics
    The CPL51E operates on a potentiometric measuring principle, with pH measurement suitability for drinking water, wastewater, and process water applications. Its characteristic is a digital Memosens 2.0 pH sensor designed for laboratory measurements and random field sampling. The sensor is robust and features a plastic shaft to withstand field use while preserving measurement integrity. The pH measuring range spans from 0 to 14, with a 1 to 12 application range tailored to most drinking water and process water scenarios. Construction materials include glass and polymer components that ensure chemical resilience and stable electrode responses. The physical dimensions specify a 12 mm (0.47 inch) diameter and a shaft length of 120 mm (4.72 inches), balancing reach and maneuverability in tight sampling ports. Process temperature tolerance extends from -5 to 80 °C (23 to 176 °F), enabling operation across typical municipal and industrial water systems. Process pressure is rated at 1 bar and explicitly noted as not intended for continuous measurement in process lines, highlighting its suitability for spot checks, grab samples, and field verifications rather than continuous inline monitoring. The temperature sensor uses an NTC 30kΩ resistor, a common choice for accurate temperature compensation in practical ranges. The inductive, digital connection head leverages Memosens technology to secure a stable data connection and robust calibration data management. The device features IP68 ingress protection, ensuring reliable performance under moisture exposure, submersion, or washdown conditions typical in water treatment settings.
  5. Operational workflow for field sampling and laboratory integration
    Begin by attaching the CPL51E to the Liquiline Mobile CML18 handheld analyzer. The inductive Memosens connection creates a secure, moisture-resistant link that supports rapid data communication with the handheld device. As the sensor is pre-calibrated, operators can initiate measurements immediately after connection, minimizing downtime between sampling events. For field sampling, deploy the sensor to measure pH in drinking water lines, wastewater collection points, or process water streams without requiring online slid-in instrumentation. When citations or regulatory sampling is necessary, the device supports on-site analysis to verify system performance and identify excursions before lab-bound samples are collected or analyzed. In laboratory settings, the CPL51E can be employed for grab samples or calibration checks, complementing more comprehensive laboratory analytics. The automatic temperature compensation ensures readings stay accurate despite ambient or process temperature fluctuations, enhancing reliability in variable field conditions. The open aperture reference helps maintain clean measurements by reducing particulate clogging, which is a frequent challenge for other sensor designs. Because the sensor stores calibration history and serial numbers in digital form, auditing and quality management tasks are streamlined, satisfying industry standards for traceability.
  6. Quality, compliance, and store-front assurances for buyers
    In addition to technical performance, CPL51E offers strong compliance and traceability features. The digital Memosens 2.0 interface ensures tamper-proof storage of calibration records and serial numbers, supporting quality management systems such as ISO 9001 and similar frameworks. The USB-like digital protocol enables straightforward data export and integration into laboratory information management systems (LIMS) or other measurement databases, facilitating robust audit trails. When purchasing CPL51E, customers can rely on authenticity guarantees from reputable distribution partners and authorized retailers. One of the key advantages for buyers is the combination of field-ready ruggedness and laboratory-grade accuracy, enabling flexible workflows across a wide range of sampling scenarios and organizational structures. The product’s design ensures compatibility with a variety of Endress+Hauser accessories, including the Liquiline Mobile CML18, which expands the device’s operational envelope to include mobile measurement campaigns, rapid verification tasks, and cross-site data gathering. The overall system architecture emphasizes ease of use, reliable data capture, and durable field performance, making the CPL51E a preferred choice for professionals who require dependable pH measurement in challenging water conditions.
  7. Emphasis on applications and global purchasing options
    The CPL51E is particularly well-suited for applications in drinking water, wastewater, and process water that require periodic checks and quick assessments rather than persistent, continuous monitoring. Its laboratory-readiness and field-readiness make it ideal for cross-functional teams that operate in municipal water facilities, industrial treatment plants, and remote sampling sites. In practice, water utilities can deploy the CPL51E to validate on-line pH sensors, confirm the accuracy of grab samples, and verify process-control points where online sensing is not installed or is temporarily offline. The sensor’s rapid response and automatic temperature compensation enable high-quality data in a range of sample matrices, from clean drinking water to more challenging wastewater streams. For procurement, the brochure promotes tpt24 as the top global online store for this product, guaranteeing authenticity and worldwide delivery. Through tpt24, buyers gain access to authorized Endress+Hauser products, reassurance of genuine parts, and a streamlined purchasing experience with reliable shipping timelines across continents. The emphasis on authenticity is critical for users who depend on precise pH measurements for regulatory compliance, treatment optimization, and process control. The online storefront also supports customer service and post-purchase assistance, including compatibility guidance, calibration support, and technical documentation.
  8. Final overview and call to action for professionals
    Endress+Hauser’s CPL51E represents a thoughtfully engineered pH sensor designed to perform reliably in both field and laboratory environments. Its robust plastic shaft, inductive Memosens connection, pre-calibrated readiness, and compatibility with Liquiline Mobile CML18 collectively enable diverse measurement campaigns with minimal setup friction. The sensor’s applications span the essential domains of drinking water, wastewater, and process water, where checking online loops, analysis of grab samples, and on-site pH measurements at non-online process points are required. The CPL51E’s design features promote measurement integrity, including automatic temperature compensation, rapid response in challenging solutions, an open-aperture reference to reduce clogging risk, and a protective barrier for the glass membrane. The combination of field and lab capabilities, along with digital data storage, supports modern quality management practices and regulatory compliance. For professionals seeking authentic, globally available pH sensing solutions, tpt24 is presented as the premier online store offering CPL51E with guaranteed authenticity and worldwide delivery. By choosing CPL51E, you invest in a versatile, durable, and accurate pH measurement solution that can adapt to a range of water analysis tasks and data-management requirements.

Technical specifications snapshot

  • Most important technical specifications (4-item list, 5 words max each)
  1. pH measuring range: 0–14
  2. Process temperature: -5 to 80 °C
  3. Diameter and shaft length: 12 mm, 120 mm
  4. Ingress protection: IP68

Appendix: Quick reference for field deployment

  • Preparation: Verify pre-calibration status and inventory integration with Liquiline Mobile CML18.
  • Connection: Use inductive Memosens interface for moisture resistance.
  • Sampling: Perform grab samples in field or lab as needed.
  • Calibration: Although pre-calibrated, verify calibration histories in the TMP or LIMS system after initial use.
  • Storage: Maintain in appropriate environmental conditions to preserve sensor integrity.
  • Safety: Follow standard safety procedures for handling water samples and laboratory equipment.
  • Maintenance: Inspect protective membrane and shaft integrity during routine checks.

Specifications

  • Measuring principle

    Potentiometric

  • Application

    Measurements in drinking water, wastewater and process water

  • Characteristic

    Digital Memosens 2.0 pH sensor for laboratory measurements and
    random sampling in the field
    Robust pH sensor with plastic shaft

  • Measuring range

    pH 0 to 14 (1 to 12 application range)

  • Material

    Glass and polymer

  • Dimension

    Diameter: 12 mm (0.47 inch)
    Shaft length: 120 mm (4.72 inch)

  • Process temperature

    -5 to 80 °C (23 to 176 °F)

  • Process pressure

    1 bar, not intended for continues measurment in process

  • Temperature sensor

    NTC 30kΩ

  • Connection

    Inductive, digital Connection head with Memosens technology

  • Ingress protection

    IP68

Data Sheet

Download Data Sheet Of: Endress+Hauser CPL51E Digital pH sensor Memosens