 Introduction to Endress Hauser D 200 Proline Prowirl vortex flowmeter

Endress Hauser D 200 Proline Prowirl vortex flowmeter is engineered for ancillary and basic process duties where footprint, installation time, and total installed cost matter most. As a wafer-style meter, it fits directly between existing flanges, so you can modernize a line without the extra space and mechanical work typical of fully flanged instruments.

When you source the meter through TPT24, you get a buyer-focused path to a correct selection: genuine Endress+Hauser equipment plus technical consultation and quotation support aligned with real process conditions.

Whether you need to measure energy consumption from steam or precisely control gas flows, the Prowirl D 200 provides reliable and accurate data, making it an indispensable asset in any facility. To better understand the core engineering behind these devices, you can explore the guide on Vortex Shedding Flowmeters: How They Work and Where to Use Them.

Key benefits of Endress Hauser D 200 Proline Prowirl vortex flowmeter

This Endress Hauser D 200 Proline Prowirl vortex flowmeter is particularly attractive when you want to replace orifice plates or standardize on a single, robust technology across multiple utility services. Because it is built on a proven vortex measuring principle, it delivers stable measurement without the ongoing maintenance burden often associated with differential-pressure primary elements.

Another practical advantage is its compact mechanical concept. The short face-to-face design helps simplify retrofits, reduce structural load, and keep modifications small, especially in crowded skids and utility manifolds.

 Built for fast retrofits and orifice plate replacements

If your site has multiple points where an orifice plate is used mainly for indication or basic control, the Endress Hauser D 200 Proline Prowirl vortex flowmeter can be evaluated as a direct modernization path. The goal is straightforward: keep the piping envelope similar while improving repeatability and reducing routine intervention.

In many plants, the value comes from lowering operational friction. Less troubleshooting around impulse lines and fewer mechanical parts to service typically translates into better availability and less unplanned work.

Endress Hauser D 200 Proline Prowirl vortex flowmeter

Measurement versatility: steam, gases, and liquids

Endress Hauser D 200 Proline Prowirl vortex flowmeter supports a wide spread of utility and process media, including wet, saturated, and superheated steam, as well as industrial gases and liquids. This versatility makes it a strong candidate for energy monitoring around boilers and distribution headers, as well as for general flow monitoring in balance-of-plant services.

For teams focused on energy accountability, the ability to use a vortex flow platform across steam applications is especially useful. It enables more consistent instrumentation standards across units, which improves maintainability and operator confidence.

 Energy and mass flow context for steam services

In steam systems, accurate flow is the foundation for energy management and cost allocation. With the Endress Hauser D 200 Proline Prowirl vortex flowmeter, you can build a measurement point that supports better visibility into consumption trends and operational opportunities.

Where integrated temperature measurement is used in saturated steam duties, it can support more meaningful energy calculations. Final configuration should always be aligned with the specific Endress+Hauser options selected for your model.

Installation and integration advantages for existing plants

Because it is designed for minimal installation effort, Endress Hauser D 200 Proline Prowirl vortex flowmeter is well suited to brownfield upgrades. Its loop-powered concept can simplify wiring plans and reduce the need for additional power infrastructure, particularly in basic measurement points.

Operational safety is also supported through approvals intended for hazardous-area use, and the device’s built-in diagnostic capabilities. These elements help reduce risk during operation while supporting planned maintenance strategies.

Heartbeat Technology for continuous diagnostics

Endress Hauser D 200 Proline Prowirl vortex flowmeter incorporates Heartbeat Technology to provide continuous diagnostic insight and in-situ verification support. This is valuable when you need confidence that measurement integrity is maintained over time, especially in utility services that still have critical cost or safety implications.

By identifying abnormal conditions early, diagnostic functions can support a more proactive approach. That means fewer surprises and more predictable maintenance windows.

Why buy Endress Hauser D 200 Proline Prowirl vortex flowmeter from TPT24

TPT24 (tpt24.com) specializes in instrumentation and measurement equipment, and supports buyers who need fast technical alignment before purchasing. For the Endress Hauser D 200 Proline Prowirl vortex flowmeter, that includes helping you match the correct size, pressure class, temperature capability, and approvals to your operating conditions based on the official Endress+Hauser documentation.

You also reduce procurement risk by sourcing genuine Endress+Hauser products through a supplier that understands industrial measurement selection, not just part numbers.

Conclusion: standardize compact vortex flow measurement

Endress Hauser D 200 Proline Prowirl vortex flowmeter is a compact, wafer-style choice for steam, gas, and liquid measurement where simplicity and uptime matter. To specify the right configuration and receive a formal quotation for your application, request a quote directly on tpt24.com for the Endress Hauser D 200 Proline Prowirl vortex flowmeter.

Specifications

SpecificationDetails
Measuring principleVortex
Product headlineCost-effective wafer flowmeter, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. For all basic applications and for 1-to-1 replacement of orifice plates.
Sensor featuresEasy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor. Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.
Transmitter featuresConvenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter rangeDN 15 to 150 (½ to 6″)
Wetted materialsMeasuring tube: 1.4408 (CF3M)
DSC sensor: 1.4435 (316/316L)
Measured variablesVolume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. measurement errorVolume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 %
Measuring rangeLiquid: 0.25 to 625 m³/h (0.15 to 365 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 2.1 to 8335 m³/h (1.2 to 4906 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Max. process pressurePN 40, Class 300, 20K
Medium temperature rangeStandard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
Ambient temperature rangeCompact version (standard): –40 to +80 °C (–40 to +176 °F)
Compact version (option): –50 to +80 °C (–58 to +176 °F)
Remote version (standard): –40 to +85 °C (–40 to +185 °F)
Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor housing materialSensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter housing materialAlSi10Mg, coated; 1.4404 (316L)
Degree of protectionCompact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
InputsCurrent input 4‐20 mA (passive)
Digital communicationHART, PROFIBUS PA, FOUNDATION Fieldbus
Power supplyDC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous area approvalsATEX, IECEx, cCSAus, JPN, EAC, UK Ex
Product safetyCE, C-TICK, EAC
Functional safetyFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificatesABS, LR, BV, DNV
Pressure approvals and certificatesPED, CRN
Material certificates3.1 material
NACE MR0175/MR0103, PMI (on request)

Data Sheet

Download Data Sheet Of:Endress+hauser D 200 Proline Prowirl vortex flowmeter