Endress+hauser F 300 Proline Promass Coriolis flowmeter
- Accuracy: ±0.05% mass flow
- Temperature Range: -196 to +350 °C
- Measurement: Flow, density, temperature
- Verification: Heartbeat Technology integrated
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser Promass F 300: Premium Accuracy Flowmeter
Unmatched Accuracy in Demanding Process Conditions
The Endress+Hauser Promass F 300 has earned a long-standing reputation for its exceptional accuracy, making it a go-to choice for a broad range of applications. It is remarkably immune to fluctuating and harsh environmental conditions, ensuring reliable performance wherever it’s installed. The Coriolis measuring principle operates independently of physical fluid properties such as viscosity or density, providing the highest measurement performance for both liquids and gases under varying, demanding process conditions.
Broadest Range of Applications Met Reliably
Thanks to its robust design and advanced Coriolis measurement technology, the Promass F 300 is suited for the broadest spectrum of applications. Whether dealing with challenging process conditions or requiring precise measurement of mass, density, and temperature simultaneously, this flowmeter excels. Its ability to handle a wide temperature range, from -196 to 350 °C, further enhances its versatility across diverse industrial sectors.
Compact Transmitter Enhances Operational Flexibility
The Promag F 300 features a compact transmitter that offers high flexibility in operation and system integration. Designed for access from one side, it allows for space-saving installations as it requires no specific in- or outlet run. This design, coupled with remote display options and improved connectivity, significantly reduces complexity and installation time, making it an efficient solution for any plant.
Multivariable Measurement for Process Insights
This flowmeter offers significant benefits by providing multivariable measurement capabilities, capturing flow, density, and temperature simultaneously. This means fewer process measuring points are needed, simplifying instrumentation and reducing costs. Users gain full access to process and diagnostic information through numerous, freely combinable I/Os and fieldbuses, enabling detailed insights and optimized process control.
Heartbeat Technology Ensures Measurement Reliability
The integration of Heartbeat Technology in the Promag F 300 provides enhanced measurement reliability and allows for the extension of recalibration cycles. This feature enables comprehensive verification of the measuring system, ensuring that the device continues to perform within its specified accuracy limits. This not only improves process safety but also reduces maintenance overhead and downtime.
Premium Performance for Liquids and Gases
The Promass F 300 delivers the highest measurement performance for both liquids and gases, even under the most challenging process conditions. Its mass flow measurement accuracy can reach an impressive ±0.05% with the PremiumCal option. This level of precision, combined with its robustness and immunity to process fluctuations, makes it an invaluable tool for critical applications where exact measurement is non-negotiable.
Your Premier Global Source: Discover tpt24 for Promag F 300
For applications demanding premium accuracy, exceptional robustness, and flexible system integration in harsh environments, the Endress+Hauser Promag F 300 is the definitive choice. tpt24 is the premier global online store for this outstanding flowmeter. We provide an absolute guarantee of product authenticity and superior quality with every purchase. tpt24 ensures your Promag F 300 meets the highest performance standards, and our worldwide delivery network guarantees secure and efficient procurement to any country, establishing us as your essential global partner.
Specifications
-
Measuring principle
Coriolis
-
Product headline
Flowmeter with premium accuracy, robustness and a compact, easily accessible transmitter.
Highest measurement performance for liquids and gases under varying, demanding process conditions. -
Sensor features
Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (³⁄₈ to 10″). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. -
Nominal diameter range
DN 8 to 250 (⅜ to 10″)
-
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +240 °C (–58 to +464 °F)
High temperatur option: –50 to +350 °C (–58 to +662 °F)
Option: –196 to +150 °C (–320 to +302 °F) -
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
Standard: 1.4301 (304)
Option: 1.4404 (316/316L) -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
-
Degree of protection
Compact version: IP66/67, type 4X enclosure.
External WLAN antenna: IP67
IP69 -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic liquids)
NTEP (Liquids other than water, LPG, cryogenic liquids)
MC (Liquids other than water, gases, cryogenic liquids)
MI-002, PTB -
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval, CCS approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK -
Hygienic approvals and certificates
3-A, EHEDG, cGMP