Endress+hauser FLOWSIC600 ultrasonic flowmeter

SKU: 4695814-1-1035-903
In Stock

  • Medium temperature range: -40 °C to +180 °C
  • Operating pressure range: 0 to 250 bar (g)
  • Nominal pipe size: DN 50 to DN 600
  • Digital Communication: Modbus, HART

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Brand:

Description

Endress+Hauser FLOWSIC600: Precision in Gas Flow

The Endress+Hauser FLOWSIC600 stands as a paramount achievement in ultrasonic flow measurement, consistently setting industry benchmarks. This device is not merely a piece of equipment; it’s a testament to engineering excellence, designed with an intrinsic understanding of the challenging environments it operates within. Its robust construction and compact design, featuring integrated cable routing, contribute to a measuring system that promises durability, unparalleled reliability, and minimal maintenance. This ensures a long operational lifespan and consistent performance, a critical factor for industries where precision and uptime are non-negotiable. The FLOWSIC600’s commitment to stability over time means fewer interruptions and more reliable data, a true cornerstone for efficient industrial processes.

Unwavering Performance for Demanding Environments

The FLOWSIC600’s design philosophy centers on resilience and adaptability, making it perfectly suited for the most demanding industrial applications. It excels in environments where other flowmeters might falter, thanks to its intelligent self-diagnostics capabilities. This advanced feature allows for proactive fault detection, ensuring that potential issues are identified and addressed long before they can impact measurement accuracy or operational efficiency. Furthermore, the FLOWSIC600 offers sophisticated process monitoring based on sound velocity, providing an additional layer of insight into your gas flow dynamics. This comprehensive diagnostic suite empowers operators with the knowledge to maintain optimal performance and prevent costly downtime, a true advantage in today’s fast-paced industrial landscape.

Mastering Diverse Gas Flow Challenges

One of the FLOWSIC600’s most significant strengths lies in its versatile application across a wide spectrum of gas flow scenarios. It is exceptionally well-suited for process gases flow metering, handling everything from common industrial gases like CO2, H2, Air, N2, O2, NH3, Ethylene, Helium, and Argon with remarkable accuracy. Beyond standard applications, it excels in internal allocation measurement, providing precise data for internal accounting and process optimization. A particular highlight is its capability to meter gases with high H2S components, such as sour gas or biogas, without compromising on performance or longevity. This broad applicability makes the FLOWSIC600 an indispensable tool for a multitude of industries, ensuring reliable measurements regardless of the gas composition.

Advanced Features for Optimal Gas Measurement

The FLOWSIC600 is packed with cutting-edge device properties that underscore its superiority. At its heart are highly efficient ultrasonic transducers, capable of operating reliably in gas temperatures up to +105 °C and under pressures reaching 250 bar. The direct path layout further enhances its measurement accuracy and stability. Intelligent self-diagnostics, a compact and robust design, an integrated log book, and a data logger all contribute to its high functionality. With an impressive measuring range of 1:120, bidirectional measurement capabilities, and remarkably low power consumption of less than 1W, the FLOWSIC600 offers a comprehensive solution that is both powerful and economical. These features collectively ensure peak performance and operational efficiency.

Benefits Beyond Conventional Flow Metering

The advantages of integrating the FLOWSIC600 into your operations extend far beyond mere measurement. Its inherent long-term stability guarantees reliable data over extended periods, minimizing the need for frequent recalibrations. The intelligent self-diagnostics drastically reduce maintenance requirements, allowing your team to focus on core tasks rather than troubleshooting. A standout benefit is its virtual immunity to pressure regulator noise, a common challenge in gas flow measurement that can otherwise compromise accuracy. The ability to exchange ultrasonic transducers under operating pressure further enhances its practicality and reduces service interruptions. Ultimately, the FLOWSIC600 offers a wide application range, making it a truly versatile and beneficial investment for any gas processing facility.

Unrivaled Accuracy with Ultrasonic Principle

The FLOWSIC600 employs the highly effective ultrasonic transit time difference measurement principle. This sophisticated method allows for the precise determination of volumetric flow, acoustic volume, gas velocity, and sound velocity. It can accurately measure a diverse range of mediums, including natural gas, air, C2H4, steam, and various process gases such as CO2 (up to 100%), N2, O2, and Cl2. Crucially, it also handles gases with high H2S content, like sour gas or biogas, with exceptional accuracy. With a repeatability of less than 0.1% of the measured value and accuracy ranging from ≤ ±1% for the 2-path version to ≤ ±0.5% for the 4-path version, the FLOWSIC600 delivers data you can unequivocally trust, underpinning critical decision-making processes.

Unlocking Global Excellence with tpt24

For those seeking to acquire this pinnacle of gas flow measurement technology, look no further than tpt24, the world’s premier online store for industrial instrumentation. tpt24 stands as the undisputed global leader, offering the Endress+Hauser FLOWSIC600 with an unwavering commitment to authenticity and quality. When you choose tpt24, you are not just purchasing a product; you are investing in peace of mind, knowing that you receive genuine equipment backed by comprehensive quality guarantees. Regardless of your location across the globe, tpt24 ensures seamless delivery directly to your doorstep, providing unparalleled convenience and reliability. Experience the best in online industrial procurement with tpt24, where excellence meets accessibility.

Technical Prowess for Demanding Applications

The Endress+Hauser FLOWSIC600 is engineered to perform under rigorous conditions. Its medium temperature range for ATEX certification is -40 °C to +105 °C, with other Ex certifications extending up to +180 °C, showcasing its resilience. It operates effectively within an impressive pressure range of 0 bar (g) to 250 bar (g), with options up to 450 bar (g) upon request. The nominal pipe size accommodates a wide range from 2″ to 24″ (DN 50 to DN 600), making it suitable for various pipeline configurations. Digital communication options include Modbus ASCII, Modbus RTU, and HART, ensuring seamless integration into existing control systems. The FLOWSIC600 is truly a marvel of modern industrial technology, built to exceed expectations.

Specifications

  • Measuring principle

    Ultrasonic transit time difference measurement

  • Measured variables

    Volumetric flow, a. c., volume a. c., gas velocity, sound velocity

  • Measuring Medium

    Natural gas, air, C2H4, steam, process gases (e. g. CO2 up to 100%, N2, O2, Cl2 etc.), gases like sour gas or bio gas with high H2S content

  • Repeatability

    < 0.1 % of the measured value

  • Accuracy

    2-path version ≤ ± 1 %

    4-path version ≤ ± 0.5 %
    Typical accuracy, see application specific data for detailed information

  • Medium temperature range

    ATEX:
    –40 °C … +105 °C at T1, T2, T3;
    –40 °C … +91 °C at T4
    Other Ex certifications: –40 °C … +180 °C

  • Operating pressure range

    0 bar (g) … 250 bar (g)
    On request: Up to 450 bar (g)

  • Nominal pipe size

    2″ … 24″
    (DN 50 … DN 600)

  • Metrological approvals and certificates

    ISO 17089-2
    MTBF: 15.4 years

  • Hazardous area approvals

    IECEx:
    Gb/Ga Ex db eb ib [ia Ga] IIA T4
    Gb/Ga Ex db eb ib [ia Ga] IIC T4
    Ultrasonic transducers intrinsically safe

    ATEX:
    II 1/2 (1) G Ex ia/db eb ia [ia Ga] IIA/IIB/IIC T4…T1 Ga/Gb
    III 1/2 (1) G Ex ia/db eb ia [ia Ga] IIC T6 Ga/Gb
    Ultrasonic transducers intrinsically safe

    NEC/CEC (US/CA):
    Class I, Division 1, Groups B, C, D T4
    Class I, Division 2, Groups A, B, C, D T4
    Class I, Division 1, Group D T4
    Class I, Division 2, Group D T4
    Ultrasonic transducers intrinsically safe

  • Digital Outputs

    3 outputs:
    30 V, 10 mA
    Passive, electrically isolated, Open Collector or according to NAMUR (EN 50227), fmax = 6 kHz
    (scalable)

  • Digital communication

    Modbus ASCII
    Modbus RTU
    HART

Data Sheet

Download Data Sheet Of:Endress+hauser FLOWSIC600 ultrasonic flowmeter