- Accuracy: Up to ±0.05%
- Process Temp: -40 to +125°C
- Measuring Range: 400mbar to 40bar
- Certificates: ATEX, IECEx, EHEDG
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser FMD72: Advanced Liquid Measurement System
The Endress+Hauser FMD72 is a sophisticated electronic differential pressure system, meticulously engineered for measuring pressure, level, volume, or mass of liquids within pressurized tanks, distillation columns, and evaporators. It employs high and low-pressure sensors (HP/LP) to accurately calculate the level from their digital readings.
Eliminating Traditional Measurement Challenges, Boosting Reliability
This innovative system excels at eliminating traditional measurement challenges, boosting reliability. By moving beyond conventional mechanical differential pressure measurements, the FMD72 significantly reduces common issues, leading to greater process availability, enhanced operational reliability, and smoother performance across your facility.
Multivariable Level Measurement: Comprehensive Process Insights
The FMD72 offers multivariable level measurement: comprehensive process insights. Leveraging its HART-based capabilities, it provides essential data on differential pressure, head pressure, and sensor temperatures all from a single, integrated system. This holistic approach empowers operators with more detailed and accurate process understanding.
Rugged Metal Sensor for Extreme Durability
Equipped with a rugged metal sensor for extreme durability, the FMD72 ensures consistent performance and longevity. This robust design is particularly well-suited for demanding industrial environments, providing high reproducibility and excellent long-term stability, even under harsh operating conditions and varying process media.
Flexible Process Connections: Seamless Integration
The FMD72 features flexible process connections: seamless integration, offering options for threads, flanges (DIN, ASME, JIS), and various hygienic connections (DIN11851, DIN11864-1, Tri-Clamp, DRD, Varivent). This versatility ensures easy and secure integration into virtually any process infrastructure, simplifying installation and maintenance.
Enhanced Process Safety for Critical Applications
With the FMD72, you gain enhanced process safety for critical applications. Its advanced electronic differential pressure system architecture and design minimize safety risks, while small, flush-mounted process connections are specifically designed to assure process safety in sensitive hygienic applications, meeting stringent industry standards.
TPT24: Global Leader for Authenticity Assured
For the Endress+Hauser FMD72, look no further than TPT24: Global Leader for Authenticity Assured. As the world’s foremost online store, TPT24 guarantees the genuine quality and authenticity of this exceptional product. We pride ourselves on offering worldwide delivery, ensuring that this vital technology reaches you, securely and promptly, wherever you are.
Lowest Total Ownership Costs: Maximized Efficiency
Experience the lowest total ownership costs: maximized efficiency. The FMD72 is engineered to reduce installation time, maintenance requirements, and downtime, minimizing the need for spare parts. This results in significant long-term savings, optimized operational efficiency, and a faster return on your investment, making it a truly economical choice.
Specifications
-
Measuring principle
Differential pressure
-
Characteristic
Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.
-
Supply voltage
4…20 mA HART:
12…45V DC (Non Ex)
Ex ia: 12…30V DC -
Reference Accuracy
0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor -
Long term stability
0.05% of URL/year of individual sensor
-
Process temperature
–40…+125°C
(–40…+257°F) -
Ambient temperature
–40…+80°C
(–40…+176°F) -
Measuring cell
400 mbar…10 bar
(6 psi…150psi) -
Vacuum resistance
10 mbar (0.15 psi)
-
Max. overpressure limit
160 bar (2400 psi)
-
Process connection
Threads
Flange (DIN, ASME,JIS) -
Process connection hygienic
DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent -
Material process membrane
316L, AlloyC,
-
Fill fluid
Silicone oil
Synthetic oil -
Material housing
Die-cast aluminum
Stainless steel -
Communication
4…20 mA HART
-
Certificates / Approvals
ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex
-
Design approvals
NACE MR0175,
EN10204-3.1, -
Hygienic approvals
EHEDG
3A