Endress+Hauser FMD78: Precision in Measurement

The Endress+Hauser FMD78 is a cutting-edge differential pressure transmitter, featuring a robust metal sensor integrated with two capillary diaphragm seals. This sophisticated instrument is meticulously engineered for continuous measurement of pressure differences across various media, including liquids, vapors, gases, and even dusts.

When high precision and reliability are mandatory, the Endress+Hauser FMD78 stands out as the ultimate industrial choice for rigorous differential pressure monitoring. A standout feature is the embedded HistoROM data module, which significantly streamlines the management of both process and device parameters.

ENDRESSPressuremeasurement

Diverse Applications: Unmatched Process Versatility

Engineers worldwide rely on the Endress+Hauser FMD78 to handle complex level, volume, and mass measurements in extreme process conditions. Its robust design allows for accurate and stable readings even in challenging conditions such as corrosive or viscous media and high temperatures.

The adaptability of the Endress+Hauser FMD78 is further enhanced by a wide variety of process connections, including threads, flanges, pancake, and specialized hygienic connections like Tri-Clamp and DIN11851. This makes it an ideal solution for chemical processing, oil & gas, food & beverage, and pharmaceuticals.

Innovative TempC Membrane: Temperature Resilience

A key technological advancement in the Endress+Hauser FMD78 is its new TempC Membrane for diaphragm seals. This innovative feature is specifically designed to drastically minimize temperature effects on measurement accuracy and ensure short recovery times following temperature fluctuations.

The TempC Membrane actively compensates for thermal influences, ensuring that the Endress+Hauser FMD78 maintains its high accuracy of ±0.075% across an expansive process temperature range from -70°C to +400°C (-94°F to +752°F). This enhanced temperature resilience guarantees consistent and dependable performance.

Highest Safety: Certified SIL3 Protection

Safety is paramount in critical industrial operations, and the Endress+Hauser FMD78 is engineered with the highest safety standards in mind. Certified to IEC 61508 for use in SIL3 safety applications, this transmitter provides an exceptional level of protection and reliability.

Its design incorporates a gas-tight feedthrough, a crucial feature that enhances safety by preventing leakage of process media. Furthermore, the Endress+Hauser FMD78 benefits from enhanced safety through self-diagnostic functions, coupled with international explosion protection certificates like ATEX, FM, CSA, and IEC Ex.

HistoROM & Modular: Simplified Management

The Endress+Hauser FMD78 integrates the revolutionary HistoROM data management concept, significantly simplifying the entire lifecycle of the device from commissioning to maintenance and diagnostics.

This intelligent module stores all device and process parameters, allowing for fast commissioning and seamless data transfer. Maintenance is complemented by a modular design, enabling easy replacement of individual components without needing to replace the entire Endress+Hauser FMD78 instrument.

Seamless Integration: Universal Communication Support

The Endress+Hauser FMD78 offers unparalleled flexibility in system integration, supporting a wide range of communication protocols to ensure seamless connectivity within any industrial control architecture.

It is fully compatible with 4 to 20 mA HART, PROFIBUS PA, and FOUNDATION Fieldbus, allowing it to integrate effortlessly into DCS and PLC networks. This broad communication capability ensures real-time insights, making the Endress+Hauser FMD78 a future-proof solution for modern industrial automation.

Specifications

  • Measuring principle

    Differential pressure

  • Characteristic

    Digital transmitter with metallic measuring diaphragms diaphragm seals and capillaries
    Modular transmitter
    Long-term stability
    Secondary process barrier
    enhanced safety via self diagnostic functions.

  • Supply voltage

    4…20 mA HART
    10,5…45V DC (Non Ex):
    Ex ia: 10,5…30V DC
    PROFIBUS PA:
    9…32 V DC (Non Ex)
    FOUNDATION Fieldbus:
    9…32 V DC (Non Ex)

  • Reference Accuracy

    0,075% + influence of diaphragm seal

  • Long term stability

    0.08 % of URL/ year
    0.14 % of URL/ 5 years
    0.27 % of URL/ 10 years

  • Process temperature

    -70°C…400°C
    (-94°F…752°F)

  • Ambient temperature

    -50°C…85°C
    (-58°F…185°F)

  • Measuring cell

    100 mbar…40 bar
    (40 inH2O…600 psi)

  • Smallest calibratable span

    5 mbar (0.075 psi)

  • Vacuum resistance

    50 mbar (0.73 psi)

  • Max. Turn down

    100:1

  • Max. overpressure limit

    160 bar
    (2400 psi)

  • Process connection

    Diaphragm seal (Pancake, threads)
    Flanges (DIN, ASME)
    Hygienic connections
    Tri-Clamp ISO2852

  • Process connection hygienic

    Tri-Clamp
    DIN11851
    NEUMO
    Varivent
    SMS
    DRD
    Universal adapter

  • Material process membrane

    316L, AlloyC,
    Tantal,
    Gold-Rhodium
    PTFE

  • Material gasket

    None, diaphragm seal welded

  • Fill fluid

    Silicone oil,
    Inert oil,
    Vegetable oil
    Low- temperature oil
    High- temperature oil

  • Material housing

    316L, Die-cast aluminum

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex

  • Safety approvals

    SIL

  • Design approvals

    NACE MR0175
    EN10204-3.1

  • Hygienic approvals

    3A, FDA

  • Marine approvals

    GL/ ABS

  • Specialities

    Diagnostic functions
    TempC Membrane

  • Successor

    PMD78B