  • Application: Continuous Level Monitoring
  • Principle: Capacitive Rod Probe
  • Process Temp: -80°C to +200°C
  • Approvals: SIL 2, 3A, EHEDG

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Endress+Hauser FMI51: Reliable Level Monitoring Solution

The Endress+Hauser FMI51: Reliable Level Monitoring Solution is a robust, fully insulated rod probe engineered for continuous level monitoring in liquids. It is particularly adept at handling media that tend to build up and operates flawlessly even in extremely high-temperature process conditions. Its measurement principle is independent of the dielectric constant (dc) as long as the liquid’s conductivity is 100 μS/cm or higher, allowing for versatile use across various liquids without the need for recalibration.

Versatile Applications for Challenging Media

The versatile applications for challenging media highlight the FMI51’s exceptional capabilities. It’s an ideal choice for inventory management solutions when paired with the Fieldgate FXA320 for remote data acquisition. The FMI51 is a go-to for measuring various liquids, from those that form build-up to those in extreme process conditions, ensuring consistent and accurate level detection.

Capacitive Measurement Principle: Universal Use

The capacitive measurement principle: universal use ensures the FMI51’s broad applicability. This technology allows the probe to function reliably without recalibration across a wide range of liquids, provided their conductivity meets the specified threshold. This universality simplifies selection and implementation, making it a highly adaptable sensor for many industrial needs.

Engineered for Extreme Process Conditions

The engineered for extreme process conditions demonstrates the FMI51’s durability. It excels in applications with temperatures ranging from -80°C to +200°C (-112°F to +392°F) and pressures from vacuum up to 100 bar (1,450 psi). The use of corrosion-resistant materials, including PTFE, PFA, and 316L, ensures longevity and reliability even in the most demanding environments.

Safety and Compliance: SIL and Approvals

Safety and compliance: SIL and approvals are paramount with the FMI51. It is designed for use in safety systems requiring functional safety up to SIL 2, adhering to IEC 61508 standards. Furthermore, it boasts a comprehensive suite of international explosion protection certificates, WHG overfill prevention, hygienic certificates, and marine approvals, underscoring its suitability for critical and regulated applications.

TPT24: World’s Best Source for FMI51

For those seeking the Endress+Hauser FMI51, TPT24: World’s Best Source for FMI51 is your ultimate online destination. TPT24 guarantees the authenticity and quality of every product sold, coupled with reliable worldwide delivery. Trust TPT24 to provide this exceptional level of performance and dependability to your operations, no matter where you are located globally.

Interface Measurement: Complex Liquid Layers

The interface measurement: complex liquid layers capability of the FMI51 allows for the detection of interfaces between different liquids, even those with emulsion layers. This advanced functionality is crucial for applications requiring precise separation or monitoring of layered liquids, providing valuable insights and control in complex process scenarios.

Local Configuration and Data Communication

Local configuration and data communication options enhance the FMI51’s user-friendliness. It offers menu-guided local configuration via an optional plain text display, simplifying setup and adjustments. For communication, it supports 12-36V DC HART and PFM, providing flexible integration with various control systems and data logging solutions for efficient process management.

Specifications

  • Measuring principle

    Capacitive

  • Characteristic / Application

    Fully insulated rod probe, for standart- and extreme process conditions (temperature, pressure, build-up)

  • Interface measurement

    Interfaces liquid / liquid also with emulsion layers

  • Specialities

    Inactive length
    Factory calibrated
    short response time by change of value

  • Supply / Communication

    12-36V DC HART
    PFM

  • Accuracy

    Repeatablity 0,1%

  • Linearity error for conductive liquids

    <0.5%

  • Ambient temperature

    -50°C…+70°C
    -58°F…+158°F

  • Process temperature

    -80°C…200°C
    -112°F…392°F

  • Process pressure / max. overpressure limit

    Vacuum … 100 bar
    (Vaccum … 1450 psi)

  • Main wetted parts

    Insulation material: PTFE,PFA
    316L

  • Process connection

    G1/2, G 3/4, G 1, G1 1/2 /NPT 1/2, NPT 3/4, NPT 1″, NPT1 1/2
    Flanges from DN25…/ASME 1″…/JIS…

  • Process connection hygienic

    Tri-Clamp ISO02852 gap free plated
    Dairy coupling
    Flush-mounted seal

  • Sensor length

    Total length: 6m (20ft)
    Inactive length: max. 2m (7ft)

  • Max. measurement distance

    0.1 m … 4.0 m
    (0.3 ft … 13 ft)

  • Communication

    4…20mA HART
    PFM

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC

  • Safety approvals

    SIL

  • Design approvals

    EN 10204-3.1
    NACE MR0175

  • Hygienic approvals

    3A, EHEDG

  • Marine approval

    GL/ ABS/ DNV

  • Options

    Separate housing
    gas-tight probe seal

  • Application limits

    Insufficient clearance towards ceiling
    Changing, non-conductive
    media, conductivity
    < 100 μS/cm
    Notice the pressure and temperature derating