Endress+Hauser FTI51 Capacitance Point level detection Liquipoint
- Application: Point Level Detection
- Principle: Capacitive Liquid
- Process Temp: -80°C to +200°C
- Approvals: SIL, WHG, 3A
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser FTI51: Precision Level Detection for Liquids
The Endress+Hauser FTI51: Precision Level Detection for Liquids is a highly advanced capacitive rod probe designed for precise point level detection. It excels in applications involving viscous liquids that are prone to build-up, ensuring reliable operation where other sensors might fail. Its ability to detect interfaces and foam in conductive liquids, coupled with active build-up compensation, guarantees maximum reliability and versatility across a broad spectrum of demanding industrial scenarios.
Applications: Build-up, Interface, and Foam Detection
The applications: build-up, interface, and foam detection showcase the FTI51’s specialized capabilities. It is the ideal solution for liquids that tend to form build-up, preventing measurement errors and sensor fouling. Furthermore, it is adept at detecting interfaces between different liquids, enabling critical separation processes, and can reliably detect foam in conductive media, providing essential control for processes like pump management and overfill prevention.
Capacitive Liquid Sensing: Superior Reliability
The capacitive liquid sensing: superior reliability is the core of the FTI51’s performance. This measuring principle, particularly with its active build-up compensation, ensures consistent and accurate readings even in challenging environments. Unlike some other level technologies, the FTI51’s design minimizes errors caused by sticky residues or adhering media, guaranteeing operational integrity.
Engineered for Extreme Process Conditions
The engineered for extreme process conditions highlights the FTI51’s robust construction. It operates effectively within a wide temperature range, from -80°C to +200°C (-112°F to +392°F), and can withstand pressures from vacuum up to 100 bar (1,450 psi). The materials in contact with the process, such as 316L stainless steel and FDA-listed PTFE/PFA insulation, are selected for their exceptional corrosion resistance and safety compliance.
Safety, Certificates, and Broad Approvals
Safety, certificates, and broad approvals underscore the FTI51’s trustworthiness. It is designed with two-stage overvoltage protection and meets stringent safety requirements, including SIL and overfill prevention (WHG). The availability of international explosion protection certificates (ATEX, FM, CSA, IEC Ex) alongside hygienic and marine approvals ensures its suitability for the most regulated and critical applications worldwide.
TPT24: Your Premier Global FTI51 Provider
For unparalleled access to the Endress+Hauser FTI51, look no further than TPT24: Your Premier Global FTI51 Provider. As the top online store for this product, TPT24 guarantees the authenticity and quality of every unit sold. With dependable worldwide delivery, TPT24 ensures that you can secure this reliable level detection solution for your operations, regardless of your geographic location.
Cost-Effective Commissioning and Operation
Cost-effective commissioning and operation are significant advantages of the FTI51. Commissioning is simplified and expedited thanks to a unique press-of-a-button calibration process, drastically reducing setup time and labor costs. The need for recalibration after electronics replacement is also eliminated, further contributing to a lower total cost of ownership and operational efficiency.
Advanced Options for Enhanced Performance
Advanced options for enhanced performance allow the FTI51 to be tailored to specific needs. Options such as an inactive probe length, fully isolated active build-up compensation, and a ground tube enhance its application flexibility. The availability of a separate housing option extends the ambient temperature range to +120°C, providing greater adaptability for diverse installation requirements.
Specifications
-
Measuring principle
Capacitive Liquid
-
Characteristic / Application
Capacitive rod probe
-
Specialities
Interface detection
Foam detection -
Ambient temperature
-50 °C … +70 °C
(-58 °F … +158 °F)
With separate housing:
-50 °C … +120 °C
(-58 °F … +248°F) -
Process temperature
-80 °C … +200 °C
(-112 °F … +392 °F) -
Process pressure / max. overpressure limit
Vacuum … 100 bar
(Vacuum … 1450 psi) -
Main wetted parts
Insulation material: PTFE, PFA
316L -
Process connection
G 1/2 … 1 1/2
NPT 1/2 … 1 1/2
Flange from DN25…/ASME 1″…/JIS 10K… -
Process connection hygienic
Tri-Clamp ISO2852 gap free plated
Dairy coupling
Flush mount -
Sensor length
Total length of probe: max 6 m (20 ft)
-
Communication
2- wire 19-253 VAC
3-wire
PFM
Relay DPDT
DC-PNP
8/16 mA -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC
-
Safety approvals
Overfill prevention WHG
SIL -
Design approvals
EN 10204-3.1
NACE MR0175 -
Marine approval
GL/ ABS/ DNV
-
Options
Inactive length
Fully isolated active build-up compensation
Ground tube
Separate housing -
Components
Transmitter
PFM: FTC325, FTC625, FTC470Z, FTC471Z
3-wire:
FTC325 -
Application limits
Notice the pressure and temperature derating.
Notice for non conductive medium the DK.