Endress+hauser T 150 Proline t-mass thermal mass flowmeter
- First liquid thermal device.
- Conductivity independent measurement.
- Insertion DN 40 to 1000.
- Hygienic/standard sensor.
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+hauser T 150 Proline t-mass thermal mass flowmeter
The Endress+Hauser t-mass T 150 introduces a new era in thermal mass flow measurement, specifically designed for liquids. As the first thermal mass device from Endress+Hauser for liquid applications, it represents a significant leap in monitoring capabilities. This innovative instrument is primarily engineered for a wide array of water applications, but its versatility extends far beyond. Crucially, the t-mass T 150 measures independently of the fluid’s electrical conductivity, enabling its use in diverse water-based and non-water-based liquids for monitoring and trending purposes. Its ability to maintain accuracy regardless of conductivity variations makes it an indispensable tool for industries seeking precise liquid flow data. Furthermore, user-defined settings can be easily saved on the display and transferred between devices, streamlining commissioning and ensuring consistency across multiple installations.
Versatile Liquid Monitoring, Conductivity Independent
The t-mass T 150 stands out with its remarkable ability to monitor both conductive and non-conductive liquids with equal precision. This fundamental characteristic liberates users from the constraints often associated with other flow measurement technologies that are sensitive to a liquid’s electrical properties. Whether dealing with deionized water, oils, chemicals, or various process water types, the t-mass T 150 provides reliable mass flow measurements. This broad applicability ensures that industries can standardize on a single, highly efficient flowmeter for a multitude of liquid processes, simplifying inventory, training, and maintenance. Its robust design and advanced thermal measuring principle, characterized by a high operable flow range and direct mass flow measurement, guarantee accurate and repeatable results, making it an ideal choice for critical monitoring tasks across diverse industrial landscapes.
Dedicated to Diverse Water Applications
While the t-mass T 150’s capabilities span various liquids, its primary focus on water applications makes it exceptionally valuable in numerous sectors. It can be deployed in municipal water treatment plants for monitoring distribution networks, in industrial facilities for tracking cooling water or process water consumption, and even in agricultural settings for irrigation management. The ability to measure independently of electrical conductivity means it can accurately monitor purified water, softened water, or even water with low conductivity, where other flowmeters might struggle. Beyond general water management, its hygienic version sensor and SIP (Sterilization-in-Place) cleaning capability up to 130 °C (266 °F) make it perfectly suited for clean water applications in food & beverage and pharmaceutical industries, ensuring product quality and compliance with stringent hygiene standards.
Compact Design, Robust Performance Assured
The t-mass T 150 is engineered with a compact and robust transmitter, ensuring both ease of installation and long-term durability in demanding industrial environments. This compact design is particularly beneficial where space is at a premium, allowing for flexible integration into existing pipelines. The device operates with a DC 24 V power supply, further simplifying its electrical integration. Despite its compact footprint, the transmitter is equipped with essential features for modern process control, including 4-20 mA HART output for seamless communication with control systems, and pulse/frequency/switch output for versatile signal integration. This combination of a space-saving design, robust construction, and comprehensive output options contributes to the t-mass T 150’s high plant availability and makes it a cost-effective solution for reliable liquid flow monitoring.
High Repeatability, Integrated Compensation
A core benefit of the t-mass T 150 is its high process safety, derived from exceptional repeatability and linearity, largely attributable to its integrated temperature compensation. This intelligent compensation mechanism dynamically adjusts for temperature fluctuations within the liquid, ensuring that mass flow measurements remain consistently accurate, irrespective of thermal variations in the process. Such precision is paramount in applications where even minor deviations can impact product quality, efficiency, or safety. The device’s sensor, available in standard or hygienic versions, further enhances its adaptability, allowing for deployment in a wide range of industries from heavy manufacturing to food processing. This commitment to high repeatability and linearity, bolstered by integrated compensation, positions the t-mass T 150 as a highly reliable instrument for critical liquid flow trending and monitoring.
Effortless Commissioning and Maintenance
The t-mass T 150 is designed for maximum user convenience, offering fast and efficient commissioning through guided operating menus. This intuitive interface minimizes setup time and reduces the likelihood of errors, allowing operators to get the device up and running quickly. Once in operation, the t-mass T 150 proves to be a cost-effective solution due to its easy installation, negligible pressure loss, and virtually maintenance-free operation. Its robust design and integrated self-diagnostics contribute to high plant availability by continuously monitoring the device’s health and alerting operators to any potential issues. Furthermore, features like automatic data recovery for servicing mean that crucial operational data is protected, simplifying troubleshooting and ensuring continuous operation, thereby reducing overall operational costs and maximizing efficiency.
Specifications
-
Measuring principle
Thermal
-
Product headline
The flowmeter for reliable and easy monitoring of liquids. Dedicated to the
monitoring of conductive and non‐conductive liquids. -
Sensor features
High process safety – high repeatability and linearity due to integrated temperature compensation. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement. Insertion version for nominal diameter DN 40 to 1000 (1½ to 40″). Sensor in standard or hygienic version.
-
Transmitter features
Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4‐20 mA HART, pulse/frequency/switch output.
-
Nominal diameter range
DN 40 to 1000 (1½ to 40″)
-
Wetted materials
Transducer: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Insertion tube: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection:
‐ Compression fitting: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Threadolet: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Clamping ferrule: PEEK 450G; 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Tri‐Clamp; DN40 DIN 11851, DN50 DIN 11851; DN40 DIN 11864‐1A, DN50 DIN 11864‐1A: 1.4404 (316L) -
Measured variables
Mass flow, temperature, volume flow
-
Max. measurement error
Flow: ±5 % o.f.s.
-
Measuring range
226 to 14 100 000 l/h (60 to 3 730 000 gal/h)
(under reference conditions) -
Max. process pressure
PN 40
-
Medium temperature range
–20 to +100 °C (–4 to +212 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4‐line display with push buttons
Configuration via local display and operating tools possible -
Outputs
4‐20 mA HART (active)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
-
Power supply
DC 18 to 30 V
-
Hazardous area approvals
ATEX, IECEx, cCSAus
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Hygienic approvals: EHEDG, 3-A -
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
Sanitary approval: 3-A, EHEDG