Endress+Hauser TST90 iTHERM ModuLine Industrial modular thermometer
- Application: Temp difference, chemical
- Range: -50 to +400 °C
- Accuracy: +/- 0.05 K
- Material: 316Ti Stainless Steel
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser TST90: Precision Temperature Differential
The Endress+Hauser TST90: Precision Temperature Differential thermometer is a sophisticated instrument specifically designed for high-precision measurement of temperature differences using matched sensor pairs. While primarily utilized in the chemical industry, its versatile design and exceptional accuracy make it suitable for a broad spectrum of applications, particularly those involving thermal energy measurements. This device ensures consistent and reliable performance across a wide measuring range from -50 °C to +400 °C (-58 to +752 °F), making it adaptable to diverse industrial processes. The TST90’s ability to provide precise differential temperature readings is critical for optimizing energy efficiency, controlling exothermic or endothermic reactions, and ensuring product quality in sensitive manufacturing processes. Its robust construction and variety of available dimensions offer flexible application possibilities, catering to specific installation requirements and challenging operational environments.
Crucial For Chemical Process Optimization
The TST90 is crucial for chemical process optimization, playing a pivotal role in industries where exact temperature control determines reaction yield and product integrity. In chemical reactors, it precisely measures the temperature difference between inflow and outflow, enabling tight control over reaction kinetics and preventing thermal runaway. For heat exchangers, it provides accurate differential measurements to optimize energy transfer efficiency, minimizing waste and improving overall system performance. The TST90’s matched sensor pairs ensure an impressive deviation of only ±0.05 K in the range of 0 to +120 °C (+32 to +248 °F), and ±0.1 K in the range of –40 to 0 °C (-40 to 32 °F), making it an indispensable tool for processes requiring extreme precision. Its robust 1.4571 (316Ti) stainless steel thermowell material provides excellent corrosion resistance, ensuring longevity in aggressive chemical environments.
Enhancing Thermal Energy Measurement Efficiency
Beyond the chemical sector, the TST90 is highly effective in enhancing thermal energy measurement efficiency. It is universally applicable for systems involving heat generation, transfer, or dissipation. For instance, in district heating systems, it can accurately measure the temperature difference across heat exchangers to determine energy consumption and billing. In industrial furnaces or kilns, it helps optimize heating profiles by monitoring temperature gradients, ensuring uniform heating and preventing hot spots. The modular design, featuring a threaded process connection (G1/2″) and a robust welded protection tube with a 9.0 mm outer diameter, allows for flexible integration into various systems. With maximum immersion lengths up to 4,000 mm, the TST90 can reach critical measurement points in large vessels or ducts, providing comprehensive thermal insights.
Rapid Replacement For Streamlined Maintenance
One significant benefit of the TST90 is its rapid replacement for streamlined maintenance. The design allows for fast replaceability of the measuring insert, minimizing downtime during calibration or sensor exchange. This feature is particularly valuable in continuous production processes where every minute of stoppage translates to significant financial loss. The high degree of insert compatibility and design as per DIN 43772 standards further simplifies maintenance procedures, ensuring that replacement parts are readily available and easily integrated. This focus on serviceability, combined with a fast response time due to its reduced tip design (t50 = 10 s, t90 = 31 s), ensures that the TST90 not only delivers precise measurements but also contributes to the operational efficiency and cost-effectiveness of industrial facilities.
tpt24: Your Global TST90 Partner
For the Endress+Hauser TST90, tpt24: your global TST90 partner stands as the unparalleled online destination. As the world’s premier online store for this high-precision thermometer, tpt24 guarantees 100% product authenticity and unwavering quality with every order. Our commitment to excellence ensures that you receive a genuine Endress+Hauser product, manufactured to the highest standards. No matter your global location, tpt24 provides reliable and efficient worldwide delivery, bringing this essential piece of process instrumentation directly to your facility. Choose tpt24 for peace of mind, knowing you are investing in a product backed by authenticity, quality assurance, and superior global service.
Durable Design With Welded Protection
The TST90 features a durable design with welded protection tube, ensuring robustness and longevity in demanding industrial environments. The protection tube is made from 1.4571 (316Ti) stainless steel, a material known for its excellent resistance to corrosion and high temperatures, making it suitable for aggressive media often found in chemical plants. This integrated thermowell design provides superior mechanical stability and protects the sensitive measuring insert from process forces and media, thus extending the lifespan of the instrument. The thermometer’s robust construction and protection class up to IP68 further underscore its ability to withstand harsh conditions, including dust ingress and prolonged immersion in water, ensuring reliable performance in challenging applications.
Precise Matched Pair Temperature Sensing
At the heart of the TST90 lies precise matched pair temperature sensing, which is fundamental to its high accuracy in differential temperature measurements. This sophisticated approach involves pairing two PT100 Resistance Temperature Detectors that are meticulously calibrated together to minimize individual sensor deviations. This careful matching allows the TST90 to achieve an outstanding accuracy of +/- 0.05 K (referring to delta-T), a level of precision critical for energy balance calculations, process control optimization, and scientific research. By compensating for individual sensor variances, the TST90 delivers highly reliable and repeatable differential temperature data, providing engineers with the confidence needed for critical process monitoring and control decisions.
Versatile For Many Industrial Applications
The TST90 is remarkably versatile for many industrial applications, thanks to its modular assembly and configurable features. While primarily used in the chemical sector, its ability to measure temperature differences accurately extends its utility. For example, in HVAC systems, it can monitor the efficiency of chillers or boilers by measuring inlet and outlet temperatures. In food processing, it can ensure proper pasteurization or sterilization by precisely controlling heating and cooling cycles. The inclusion of a neck and threaded process connections (G1/2″ male thread) provides installation flexibility. This broad adaptability, combined with its high-precision capabilities, makes the TST90 a valuable asset across diverse industrial landscapes requiring meticulous thermal management.
Specifications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
modular temperature assembly (paired)
threaded process connection
with neck
incl. thermowell / protection tube (metal) -
Thermowell / protection tube
welded protection tube
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
9,0 mm (0,35”)
-
Max. immersion length on request
up to 4.000,00 mm (157,48”)
-
Material protection tube/ thermowell
1.4571 (316Ti)
-
Optional coating
Not defined
-
Process connection
male thread:
G1/2″ -
Tip shape
straight
tapered -
Surface roughness Ra
Not defined
-
Operating temperature range
PT 100:
-50 °C …400 °C
(-58 °F …752 °F) -
Max. process pressure (static)
at 20 °C: 50 bar (725 psi)
-
Accuracy
+/- 0.05 K (refering to delta-T)
-
Response time
depending on configuration
t50 = 10 s
t90 = 31 s -
Integration head transmitter
no