  • Application: Hygienic/aseptic processes
  • Design: Metric style
  • Pressure: Up to 40 bar
  • Material: 316L stainless

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Category:
Brand:

Description

Endress+Hauser TT411: Hygienic Design for Processes

The Endress+Hauser TT411: Hygienic Design for Processes is best suited for applications in hygienic and aseptic pipes, containers, or tanks. Even with very small immersion lengths, it ensures increased protection of the temperature sensor against physical and chemical effects. This thermowell is ideally suited to measuring points requiring regular recalibration, thanks to the easy replacement of the insert in closed processes. Its hygienic design and robust construction make it indispensable for critical measurement tasks in stringent environments.

Designed for Aseptic and Hygienic Needs

This thermowell is designed for aseptic and hygienic needs specifically in the Food & Beverages and Life Sciences industries. Meeting the stringent requirements of these sectors, the TT411 offers exceptional reliability and minimizes the risk of contamination. Its design allows for easy cleaning and sterilization, complying with international hygiene standards. The TT411 ensures accurate temperature monitoring while upholding the highest levels of cleanliness, crucial for maintaining product quality and safety in sensitive applications.

Enhanced Protection Against Physical Stress

The TT411 provides enhanced protection against physical stress and chemical effects, safeguarding temperature sensors from harsh conditions. Its robust construction and material selection ensure that the sensor is shielded from mechanical forces, vibrations, and corrosive substances. This protection is critical in maintaining the integrity and accuracy of temperature measurements, preventing sensor damage and extending the service life. The TT411’s durable design contributes to operational efficiency and safety in challenging industrial settings.

Cost and Time Savings Recalibration

Cost and time savings recalibration are achieved with the iTHERM QuickNeck feature of the TT411. This innovative design allows for simple, tool-free recalibration of the insert, significantly reducing downtime and maintenance costs. The QuickNeck mechanism allows for the swift replacement of the temperature sensor without requiring a process shutdown, keeping operations running smoothly. The TT411’s design enhances efficiency and reduces the overall cost of ownership for temperature monitoring systems.

Global Portfolio with Metric/Imperial Versions

A global portfolio with metric/imperial versions of the TT411 offers versatility and adaptability for various installations. Whether requiring metric or imperial standards, users can select the version that best fits their needs, ensuring seamless integration into existing systems. The international certification of the TT411, including hygiene standards such as 3-A®, EHEDG, ASME BPE, FDA, and TSE Certificate of Suitability, confirms its quality and compliance. This global portfolio makes the TT411 a reliable choice for any location or application.

Broad Range of Hygienic Connections

The TT411 features a broad range of hygienic connections, including over 50 different process connections, enhancing its adaptability to diverse installations. Options include compression fittings, weld-in adaptors, clamp connections (ISO2852), screwed pipe joints (DIN 11851), aseptic screwed pipe joints (DIN 11864-1), and more. These various connection possibilities ensure compatibility with a wide range of equipment and processes. The TT411 provides flexibility and ease of integration, making it suitable for use in various applications across the Food & Beverage and Life Sciences industries.

Your Premier tpt24 Global Source

The Endress+Hauser TT411 is available from your premier tpt24 global source, recognized as the world’s leading online store for high-quality process instrumentation. At tpt24, we guarantee the authenticity and superior quality of every TT411 unit you purchase. Our commitment includes secure and reliable worldwide delivery, ensuring that your critical components arrive on time and in perfect condition. Trust tpt24 for guaranteed authenticity, unparalleled quality, and global accessibility.

Optimized Tip for Fast Response Times

Featuring an optimized tip for fast response times, the TT411 ensures quick and accurate temperature measurement, critical for process control. Reduced tips with thin walls allow for rapid heat transfer, enabling precise and immediate temperature readings. State-of-the-art Tee and Elbow thermowells, designed without welds or dead legs and with best-in-class hygienic design, further enhance performance. The TT411’s design maximizes efficiency and ensures reliable temperature monitoring.

Specifications

  • Measuring principle

    Fabricated Thermowell

  • Characteristic / Application

    metric style
    hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
    hygienic process connections
    iTHERM QuickNeck for easy and cost saving recalibration

  • Head connection

    iTHERM QuickNeck
    male thread:
    M24x1,5
    G3/8″

  • Maximum standard immersion length

    4.000 mm (157,48″)

  • Max. immersion length on request

    Not defined

  • Process connection

    compression fitting
    weld in adaptor
    clamp connections acc. to ISO2852
    screwed pipe joint acc. to DIN 11851
    aseptic screwed pipe joint acc. to DIN 11864-1
    metallic sealing system
    thread acc. to ISO 228 for liquiphant adaptor APV Inline
    Varivent
    Ingold
    SMS 1147
    Neumo Biocontrol
    Tee and elbow thermowells DIN11865

  • Thermowell root diameter

    6,0 mm (0,24″)
    9,0 mm (0,35″)
    12,7 mm (0,5″)

  • Medium contact material

    1.4435 delta-ferrit < 1%
    316L

  • Wetted part finishing (Ra)

    < 0,76 μm (29,92 μin)
    < 0,38 μm (14,96 μin)
    < 0,38 μm (14,96 μin) electropolished

  • Tip shape

    straight
    reduced
    tappered

  • Temperature range

    -200…650 °C (-328…1.202 °F)

  • Max. process pressure (static)

    40 bar (580 psi)

  • Max. process pressure at 400 °C

    depends on process connection