  • ±1000 mV ORP Measurement Range
  • ±5 mV Accuracy @25°C
  • 4–20 mA Recorder Output
  • Adjustable 5–30 min Overtime

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Compact ORP Controller For Precise Process Regulation

The Hanna BL932700 ORP Mini Controller is a compact yet highly capable solution for monitoring and controlling oxidation‑reduction potential (ORP) in industrial and commercial water treatment systems. Its design prioritizes space efficiency and affordability without compromising accuracy or control flexibility, making it ideal for installations where footprint and cost efficiency are critical. Compatible with any ORP electrode featuring a standard BNC connector, the BL932700 allows users to precisely configure dosing above or below a user‑defined mV setpoint. Operation modes can be switched between automatic or manual dosing, enabling maintenance teams to troubleshoot systems without disrupting ongoing process flows. Featuring a large clear LCD and a fire‑retardant casing, the unit combines safety and performance in demanding process environments.

Adjustable Dosing And Overdose Protection Features

At the core of the BL932700’s operational flexibility is its adjustable dosing relay, which can be set to deliver oxidizing or reducing agents depending on process conditions. Whether the goal is to maintain oxidizing ORP levels in chlorination systems or to sustain reductive conditions in specialized chemical manufacturing, dosing control is accurate and repeatable. The controller’s overdose protection safeguards against prolonged activation of pumps or valves by automatically shutting down dosing actions if the set overtime period — adjustable between 5 and 30 minutes — is exceeded. Such protection is vital in preventing reagent wastage, tank overflow, or chemical imbalance that could damage sensitive equipment downstream.

Selectable Control Override And Safety Integration

Beyond standard automation, the BL932700 mini controller includes a selectable control override function, enabling connected devices to be forced into “always On” or “always Off” status with a simple switch adjustment. This is particularly useful during scheduled maintenance, system flushing, or emergency shutdown scenarios. Additionally, its external disabling feature allows integration with safety devices such as level controllers or flow monitors, preventing inadvertent dosing during abnormal conditions like low flow rates, empty supply tanks, or blocked lines. This hardware‑level safety loop provides assurance in continuous operation plants, where uninterrupted production and system protection are paramount.

Robust Analog Output For Data Integration

Equipped with a 4–20 mA analog output, the BL932700 seamlessly communicates with data loggers, chart recorders, or SCADA systems, ensuring that ORP performance data is captured and archived for process optimization. Integration with plant‑wide monitoring networks allows engineers to correlate ORP values with other operational parameters such as pH, temperature, and flow rates. The matching pin connection feature protects sensors from ground loop interference, maintaining stable readings in electrically noisy environments — a common challenge in large industrial installations. This combination of precision sensing and robust output signaling makes the BL932700 equally suited for standalone operation or networked process control systems.

Wide Range Of Industrial And Commercial Applications

The versatility of the Hanna BL932700 makes it a go‑to solution across numerous industries. In municipal water treatment facilities, it ensures oxidation levels meet regulatory safety standards. In food processing plants, it helps maintain ORP conditions for sanitation and quality control. Aquaculture farms employ it to monitor water chemistry, creating safe habitats for sensitive aquatic species. Electroplating operations depend on precise ORP control to achieve uniform coating thickness and prevent contamination. Additionally, the compact format makes it ideal for small‑scale research labs and mobile treatment units, where portability and efficient installation are primary concerns. The BL932700’s rugged design and reliability make it equally effective in continuous flow‑through monitoring or batch treatment systems.

Reliable Calibration And High Measurement Accuracy

The BL932700 offers a full ±1000 mV range with a resolution of 1 mV and an accuracy of ±5 mV at 25°C / 77°F. Calibration is performed manually via a dedicated CAL trimmer, giving operators fine control over baseline measurement settings. The input impedance of 10^12 Ohm ensures minimal signal distortion from electrode outputs, while the unit’s fuse‑protected dosing relay operates at up to 2 A for driving high‑load devices without risk of overcurrent damage. In environments where power options vary, two models are available: BL932700‑0 powered by 12 VDC and BL932700‑1 powered by 115/230 VAC at 50/60 Hz. This flexibility allows deployment in fixed installations or mobile configurations without complex electrical work.

Durable Construction And Easy Panel Installation

Designed for dependable performance in rugged conditions, the BL932700 features a fire‑retardant casing, transparent protective cover, and supplied mounting brackets. Installation is straightforward with cut‑out dimensions of 83 x 53 mm and an extended depth of 99 mm, allowing secure placement into standard control panels. Adjustable slide brackets ensure tight, vibration‑resistant positioning — critical in facilities where mechanical shock might occur. Its weight of just 200 g for the BL932700‑0 and 300 g for the BL932700‑1 favors ease of handling and minimizes load on lightweight control panel frames. The recommended HI2001 PVDF ORP electrode with a 1/2 in. NPT thread and 3 m cable offers optimal performance in continuous monitoring applications (available separately).

Global Availability From Leading Online Retailer tpt24.com

Acquiring the BL932700 ORP Mini Controller is simplified by tpt24.com, recognized as the world’s leading online retailer for this product. Every unit supplied by tpt24.com is backed by an authenticity and quality guarantee, ensuring you receive genuine Hanna Instruments equipment regardless of your location. With worldwide delivery and dedicated support for installation and application guidance, tpt24.com ensures your process control systems are equipped with top‑tier instrumentation. Whether upgrading existing treatment lines, installing new monitoring stations, or expanding into advanced data acquisition, purchasing through tpt24.com delivers confidence in both product and service quality. Their commitment to fast, secure shipping means operational readiness is just days away for customers worldwide.

Specifications

ORP Range ±1000 mV
Resolution 1 mV
Accuracy (@25°C / 77°F) ±5 mV
Calibration Manual, via CAL trimmer
Dosing Relay Max 2A (fuse protected), 250 Vac, 30 VDC
Dosing Selection Reducing or Oxidizing, selectable via back panel
Setpoint Adjustable from –1000 to +1000 mV
Overtime Protection Adjustable from 5 to approx. 30 minutes
Recorder Output 4–20 mA, ±0.20 mA accuracy, 500 Ω max load
Input Impedance 10^12 Ohm
Power Supply BL932700‑0: 12 VDC / BL932700‑1: 115/230 VAC 50/60Hz
Dimensions 83 x 53 x 99 mm (3.3 x 2.1 x 3.9″)
Weight BL932700‑0: 200 g / BL932700‑1: 300 g
Recommended Probe HI2001 PVDF body ORP electrode (sold separately)