Hanna HI1210T Combination PEI-body pH Electrode- General Purpose

In Stock

  • Body Material: PEI construction
  • Connector Type: T-type interface
  • Temperature Range: –15°C to 80°C
  • Max Pressure: 3 bar (43.5 psi)

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Durable PEI Body for Industrial pH Measurement

The Hanna HI1210T Combination PEI-body pH Electrode – General Purpose is specifically engineered for industrial environments where durability, chemical resistance, and mechanical strength are critical. The PEI (polyetherimide) body offers outstanding resilience against physical impacts, thermal fluctuations, and a broad spectrum of chemical exposure, making it ideal for noncritical yet demanding pH measurement tasks. This electrode integrates sensing and reference components in a single compact unit, simplifying installation and maintenance. Its rugged design ensures extended service life even in continuous operation scenarios, making it a dependable choice for professionals who operate in challenging process environments.

Advanced General Purpose Glass Formulation Benefits

A key performance feature of the HI1210T is its general purpose pH glass formulation, which offers fast response and stable performance over the entire pH range. This composition is suitable for a wide range of liquids, from neutral to mildly acidic or alkaline solutions, thus supporting diverse applications in manufacturing plants, chemical processing, and water treatment facilities. The electrode maintains precise readings in temperature environments ranging from –15°C to 80°C (5°F to 176°F), ensuring reliable monitoring even in processes subject to thermal variations. Its adaptability allows engineers and technicians to apply it across multiple production lines without the need for frequent sensor changes.

Cloth Junction with Double Junction Technology

Hanna has designed the HI1210T with a renewable cloth junction to enhance measurement reliability and extend electrode life. The double junction configuration filled with gel polymer serves two critical functions: it shields the sensing element from contamination while delivering a stable reference signal. This structure prevents unwanted interaction between the internal electrolyte and the sample being tested, making it highly suited for use in solutions containing proteins, heavy metals, or harsh chemical compositions. The cloth material can be rejuvenated, thereby restoring electrode performance in situ and reducing downtime during critical operations.

Flexible T-Type Connector for Quick Integration

The HI1210T features a T-type connector that enables quick and secure interfacing with compatible pH/ORP meters and transmitters. This standardization allows users to swiftly replace or service the electrode without altering existing instrumentation setups. It supports fast deployment whether in laboratory bench-top settings or inline industrial systems. When combined with the PEI body durability and general purpose glass capabilities, this easy-connect functionality reinforces the electrode’s role as a versatile, efficient, and maintenance-friendly measurement solution for plant operators and laboratory technicians alike.

Wide Range of Industrial Application Uses

This electrode is widely used across multiple sectors, including municipal water treatment, chemical production plants, food and beverage processing, and environmental monitoring stations. Its clog-resistant PTFE junction is particularly beneficial in applications with viscous or particulate-rich samples, such as in paper manufacturing or wastewater treatment. By ensuring accurate readings even in challenging solution conditions, the HI1210T helps maintain regulatory compliance, process efficiency, and product quality. Its robust build is also suitable for continuous immersion setups, making it indispensable for operators seeking reliable pH monitoring in long-duration processes.

Reliability in Harsh Process Environments

The HI1210T’s operational design addresses the realities of harsh industrial settings, where extreme pH values, pressure, and temperature fluctuations occur frequently. Rated for a maximum pressure of 3 bar (43.5 psi), it can handle inline measurements without compromise. The gel polymer electrolyte resists drying and leakage, contributing to consistent long-term accuracy. Because it lacks an internal temperature sensor, it can be paired with external probes for temperature-compensated readings when needed, offering flexibility in instrument integration. This combination of features ensures that operators benefit from a low-maintenance, dependable measurement tool that stands up to operational stress.

Authentic Global Supply by tpt24.com

For organizations seeking assured quality and authenticity, the Hanna HI1210T Combination PEI-body pH Electrode is available globally through tpt24.com, recognized as the leading online distributor of this product worldwide. Tpt24.com guarantees genuine manufacturing origin, premium product integrity, and direct international shipping to any country. Customers benefit from a 6-month manufacturer warranty alongside professional support, making it a trusted partner for industries requiring precise pH measurement tools. Purchasing from tpt24.com ensures total confidence in the electrode’s compliance with specifications and performance standards.

Long-Term Value with Minimal Maintenance Demands

By combining a renewable cloth junction, general purpose pH glass, and double junction gel technology, the HI1210T minimizes both maintenance frequency and replacement costs. The electrode’s rugged PEI casing resists damage from mechanical handling, while its clog-resistant PTFE junction improves accuracy and extends lifespan. These attributes help maintain operational continuity in high-throughput environments where downtime directly impacts productivity. The HI1210T’s cost-effectiveness stems from its ability to deliver prolonged service with minimal intervention, reinforcing its value for busy industrial facilities and laboratories.

Specifications

Model / SKU HI1210T
Electrode Type Combination pH electrode
Body Material PEI
Junction Type Double, cloth
Glass Type General purpose (-15 to 80°C / 5 to 176°F)
Electrolyte Type Gel polymer
Amplifier No
Temperature Sensor No
Max Pressure 3 bar (43.5 psi)
Connector Type T-type
Electrode Length 140 mm
Junction Material PTFE clog-resistant
Warranty Period 6 months

Data Sheet

Download Data Sheet Of Hanna HI1210T Combination PEI-body pH Electrode- General Purpose