Hanna HI6000-4 Dissolved Oxygen Module

In Stock

  • Wide dissolved oxygen range.
  • Automatic temperature compensation.
  • Support for OUR, SOUR, and BOD.
  • Compatible with optical and polarographic probes.

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

A New Era in Lab Measurement Technology

The Hanna HI6000-4 Dissolved Oxygen module represents a significant leap forward in precision laboratory and research analysis. As a core component of the innovative HI6000 Multiparameter Modular System, this device is engineered to meet the exacting standards of professionals who require impeccable measurement quality and flexible instrumentation. This system’s modular design allows users to customize their laboratory setup by seamlessly integrating up to three different modules, including the HI6000-4, which is dedicated to dissolved oxygen measurement. This adaptability ensures that the platform can evolve with a user’s changing needs, making it a valuable long-term investment for any modern laboratory. The large capacitive touchscreen provides a user-friendly interface, simplifying complex procedures and offering complete control over all measurements. With its advanced features and reliable performance, the HI6000-4 module stands as a testament to Hanna Instruments’ commitment to developing cutting-edge technology for scientific applications.

Unparalleled Versatility for Diverse Applications

The versatility of the HI6000-4 module is one of its most compelling features, making it an indispensable tool for a wide range of analytical tasks. This module is specifically designed to perform accurate dissolved oxygen measurements in both freshwater and saltwater environments. Its compatibility with two distinct probe types—the HI7641133 optical dissolved oxygen (opdo®) probe and the HI764833 polarographic dissolved oxygen probe—allows for flexibility in various testing scenarios. Whether a user is conducting routine water quality checks or more complex biological studies, the HI6000-4 provides reliable results. The system is equipped with advanced features that automatically compensate for critical environmental factors such as barometric pressure, temperature, and salinity. This automatic compensation ensures that the readings are consistently accurate, regardless of fluctuating ambient conditions. This level of precision is vital for scientific research and industrial applications where minor variations can impact the integrity of results.

Our Dedicated Support for Scientific Endeavors

At tpt24, we understand that professional-grade equipment requires exceptional support. That’s why we are proud to be the premier global online store for the Hanna HI6000-4 Dissolved Oxygen Module. We are committed to providing our customers with a seamless purchasing experience and total peace of mind. Every HI6000-4 module acquired from tpt24 comes with a guaranteed assurance of authenticity and quality, ensuring that you receive a genuine Hanna Instruments product every time. Our secure and efficient delivery network is designed to ship your order to any country in the world, with the product arriving in perfect condition and ready for immediate use. Our dedicated team of specialists is always available to offer technical assistance, answer your questions, and provide expert advice on choosing the right probes and accessories to optimize your dissolved oxygen measurements. When you choose tpt24, you’re not just buying a product; you’re gaining a trusted partner dedicated to supporting your scientific and professional goals.

Advanced Methods for Precise Oxygen Analysis

The HI6000-4 Dissolved Oxygen module is uniquely equipped to handle complex analytical procedures through its support for various standardized methods, including Oxygen Uptake Rate (OUR), Specific Oxygen Uptake Rate (SOUR), and Biochemical Oxygen Demand (BOD). These guided procedures help users adhere to standard method guidelines, ensuring that data is both accurate and consistent. The OUR method is instrumental in determining the biological activity of a system by measuring the rate of oxygen consumption or respiration. This application is crucial in fields such as environmental science, wastewater treatment, and biological research, where understanding microbial activity is paramount. The SOUR method provides a measure of a system’s oxygen consumption rate, offering insights into the metabolic health and efficiency of a sample. Both OUR and SOUR measurements are essential for monitoring and optimizing biological processes.

Deeper Understanding Through Specific Applications

Beyond the standard methods, the HI6000-4 module excels in specific applications that require meticulous data collection. The Biochemical Oxygen Demand (BOD) method, for example, is a cornerstone of water quality analysis and is perfectly suited for this module. The BOD measurement determines the rate at which microorganisms in a water sample consume oxygen over a specific period, providing a critical indicator of the organic pollution level in the water. This is particularly useful in assessing the quality of effluent from industrial plants or evaluating the health of natural water bodies. Furthermore, the module’s ability to measure dissolved oxygen in both fresh and saltwater makes it an ideal tool for marine biology research, aquaculture, and oceanographic studies. The HI6000-4’s versatility allows it to be used for field monitoring as well as controlled laboratory experiments.

Calibration and Accuracy: The Hanna Promise

Maintaining the highest level of accuracy is a core principle of the Hanna HI6000-4 module. To achieve this, the device offers flexible and precise calibration options. The system supports one- or two-point automatic calibration at 100.0% saturation (8.26 mg/L) and 0.0% saturation (0.00 mg/L). For specialized applications, a one-point manual calibration is also available, allowing users to input a custom value in percentage saturation, mg/L, or ppm. This dual approach ensures that the instrument can be perfectly tuned for any measurement environment. The accuracy of dissolved oxygen measurements ultimately depends on the selected probe, which is why Hanna offers two distinct, high-quality probes for the HI6000-4: the optical HI7641133 and the polarographic HI764833. The HI7641133 optical probe provides long-term stability with reduced calibration frequency. The HI764833 polarographic probe, with its thin design, is perfect for measurements in narrow vessels like test tubes and BOD bottles.

A Design Focused on User Experience

The Hanna HI6000 series is built on a foundation of user-centric design, and the HI6000-4 module is no exception. The system features a large 7” (17.8 cm) capacitive touchscreen that supports multi-touch gestures, making navigation intuitive and efficient. The user interface is enhanced with user-friendly icons and symbols that facilitate easy interpretation of all instrument functions. Users can choose from five different display modes to view their data, including standard, simple GLP, full GLP, an interactive real-time graph, and a tabulated data view with date, time, and notes. The on-board help menu and video tutorials further simplify complex operations, providing quick assistance and ensuring a seamless experience for both novice and experienced users.

Technical Excellence and Reliable Performance

The HI6000-4 Dissolved Oxygen module is engineered for technical excellence and reliable, long-term performance. Its specifications are a testament to its capabilities. It offers a broad dissolved oxygen range from 0.0 to 500.0% saturation and 0.00 to 90.00 mg/L (ppm). The resolution is equally impressive, at 0.1% saturation and 0.01 mg/L (ppm). The integrated barometer has a range of 450.0 to 850.0 mmHg, with a resolution of 0.1 mmHg. Temperature compensation is both automatic and manual, with a range of -20.0 to 120.0 °C. Manual salinity compensation is also available, with a range of 0.00 to 45.00 PSU or g/L (ppt). These robust specifications, combined with the module’s modular design and advanced features, make the HI6000-4 a powerful and dependable tool for any professional application requiring precise dissolved oxygen measurements.

Specifications

Feature Range Resolution Accuracy
Dissolved Oxygen 0.0 to 500.0% saturation 0.1% saturation Refer to probe used

0.00 to 90.00 mg/L (ppm) 0.01 mg/L (ppm)
Barometric Pressure 450.0 to 850.0 mmHg

0.1 mmHg

±3 mmHg (within ±15% from calibration point)

600.0 to 1133.2 mbar

0.1 mBar

±3 mmHg ±1 least significant digit

60.00 to 113.32 kPa

0.01 kPa

Temperature -20.0 to 120.0 °C

0.1 °C

Refer to probe used

Salinity Compensation Manual: 0.00 to 45.00 PSU or g/L (ppt)

Data Sheet

Download Data Sheet Of Hanna HI6000-4 Dissolved Oxygen Module