  • Display: 40 x 70 mm graphic LCD
  • Log Memory: Stores up to 200 records
  • Dimensions: 230 x 200 x 145 mm
  • Light Source: Tungsten filament lamp

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Hanna HI88703 Turbidity Meter: A Comprehensive Overview

The Hanna HI88703 is an advanced benchtop turbidity meter meticulously engineered for precise water quality analysis, particularly excelling in the measurement of low-turbidity samples. This instrument is built around a state-of-the-art optical system that not only ensures highly accurate results but also guarantees long-term stability by effectively minimizing interference from stray light and sample color. A key feature is its dual measurement capability, offering both ratio and non-ratio modes to accommodate a wide range of turbidity levels, from 0.00 to 4000 NTU. The meter’s design is compliant with stringent USEPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B, making it an indispensable tool for environmental laboratories, municipal water treatment facilities, and quality control departments. The inclusion of AMCO AEPA-1 primary turbidity standards ensures that all measurements are traceable to a primary reference material, solidifying its reliability for professional use.

A stand-out attribute of the HI88703 is its user-centric design, which incorporates a variety of features to streamline the measurement process and ensure data integrity. The device is equipped with a comprehensive GLP (Good Laboratory Practice) function, which allows users to trace calibration conditions, including the date and time of the last calibration. This is crucial for maintaining accurate and verifiable records. For data management, the meter can store up to 200 measurements in its internal memory, which can be easily transferred to a PC via a USB port using the compatible HI92000 software. The inclusion of a tutorial mode and a dedicated HELP button provides on-screen guidance, making complex procedures like setup and calibration intuitive even for new users. These features collectively enhance the meter’s functionality, making it a reliable and user-friendly solution for professionals who demand both precision and efficiency in their work.

Hanna’s Innovative Design for Precision Readings

The Hanna HI88703 is a testament to cutting-edge optical engineering, designed to deliver unparalleled accuracy and stability in turbidity measurements. Its sophisticated optical system, featuring a tungsten filament lamp and multiple detectors, effectively negates external factors that could compromise results. The meter uses a scattered light detector at a 90° angle and a transmitted light detector at 180°, allowing it to function in both ratio and non-ratio modes. This dual capability is critical for a wide range of applications, as the ratio mode is ideal for samples with varying colors or high turbidity, while the non-ratio mode provides excellent linearity for low-range measurements where stray light can be a significant issue. The system is so advanced that it even compensates for fluctuations in the lamp’s intensity, which minimizes the need for frequent calibration and ensures consistent performance over time. This meticulous design makes the HI88703 a dependable instrument for professionals who cannot afford compromise on data quality.

Ensuring Compliance with EPA and GLP Standards

A core strength of the Hanna HI88703 is its strict adherence to regulatory and quality standards, most notably those set by the USEPA. The meter includes a specific EPA compliance reading mode that automatically rounds measurements to align with official EPA reporting requirements, simplifying the data submission process for users. This functionality is essential for laboratories and facilities required to meet stringent government regulations for drinking water quality and wastewater treatment. Beyond regulatory compliance, the meter also incorporates comprehensive GLP (Good Laboratory Practice) features. These functions provide a full audit trail for calibration conditions, including the date, time, and specific calibration points used, which is critical for ensuring data traceability and integrity. The use of AMCO AEPA-1 primary turbidity standards, which are officially recognized by the USEPA, further validates the meter’s accuracy and reliability.

Applications in Water Quality and Beyond

The Hanna HI88703’s versatility makes it a perfect tool for a broad spectrum of professional applications. Its primary use is in drinking water treatment plants, where monitoring turbidity is a vital safeguard against pathogens. The meter’s ability to provide highly accurate readings in low-turbidity ranges (0.00 to 40.0 NTU in non-ratio mode) is particularly critical for verifying that treated water meets or exceeds regulatory standards. In wastewater treatment, the HI88703 is used to measure turbidity at the final stage of the process to ensure that discharged water is within legal limits. For environmental monitoring, the meter is employed to gauge the general quality of natural water sources like rivers and lakes, helping to assess the compatibility of the water with aquatic ecosystems. Additionally, in the brewing and food & beverage industries, the HI88703 can measure turbidity in units like EBC (European Brewing Convention) to control the clarity and consistency of products.

Intuitive and User-Friendly Operational Interface

The HI88703 is not only powerful in its technical capabilities but also exceptionally easy to use. The device features a large, backlit graphic LCD display that presents information in clear, plain text, eliminating the need for complex codes or symbols. This user-friendly interface is supported by two unique functions: a tutorial mode and contextual help. When the tutorial mode is enabled, the meter guides the user step-by-step through operational procedures, providing clear explanations and prompts. Similarly, the dedicated HELP button provides instant, on-screen assistance relevant to the specific setting or option being viewed. These features are invaluable for both new users learning the ropes and experienced professionals who need a quick reminder, ensuring that the meter can be operated efficiently and without errors.

Seamless Data Management and Transfer Capabilities

In today’s data-driven world, the ability to effectively manage and transfer measurement data is non-negotiable. The Hanna HI88703 addresses this need by incorporating robust data logging and connectivity features. The meter can store up to 200 individual measurements in its internal memory, allowing users to collect a large dataset before needing to offload the information. For long-term storage, detailed analysis, or official reporting, the logged data can be easily transferred to a Windows-compatible PC. This is achieved by connecting the meter via its USB port, which requires the optional HI920013 USB cable and HI92000 software. This seamless data transfer capability ensures that all collected data can be securely archived, analyzed, and integrated into larger reports or databases, which is essential for quality control and compliance purposes.

The Gold Standard in Turbidity Meter Calibration

Calibration is paramount for ensuring the accuracy of any analytical instrument, and the Hanna HI88703 provides a powerful and flexible calibration system. The meter supports a two, three, four, or five-point calibration process using the supplied AMCO AEPA-1 standards. These standards are highly stable, non-toxic, and reusable, making the calibration process both reliable and cost-effective. Furthermore, the HI88703 offers the unique ability to modify calibration points if a user chooses to use their own prepared standards, providing an added layer of customization and flexibility. This feature is particularly beneficial for specialized applications where a different set of reference points may be required.

Global Availability and Authenticity via tpt24

For customers seeking this high-quality instrument, tpt24 is the leading online store globally for the Hanna HI88703. As the premier distributor, tpt24 guarantees the authenticity and quality of every product they sell. Customers can trust that they are receiving a genuine Hanna product, complete with all supplied standards and accessories, and not a counterfeit. The company offers a hassle-free delivery service to any country in the world, ensuring that this essential piece of equipment is accessible to professionals everywhere. Tpt24’s commitment to quality assurance and global logistics makes it the most reliable source for the Hanna HI88703.

Specifications

Specification Details
SKU HI88703-01
NTU Ratio Range 0.00 to 4000 NTU, 0.0 to 26800 Nephelos, 0.00 to 980 EBC
NTU Non-ratio Range 0.00 to 40.0 NTU, 0.0 to 268 Nephelos, 0.00 to 9.80 EBC
Accuracy ±2% of reading plus 0.02 NTU, ±5% of reading above 1000 NTU
Repeatability ±1% of reading or 0.02 NTU, whichever is greater
Stray Light < 0.02 NTU
Light Source Tungsten filament lamp
Log Memory 200 records
PC Interface USB
Environment 0 °C to 50 °C; max 95% RH non-condensing
Dimensions 230 x 200 x 145 mm
Weight 2.5 kg
Power Supply 230 V/50 Hz or 115 V/60 Hz
Warranty 2 years