Hanna HI9810402 HALO2 Wireless Refillable pH Tester for Lab
- pH Range: 0.00–14.00
- Accuracy: ±0.02 pH
- Temperature Range: –5 to 80 °C
- IP Rating: IP65 Water Resistant
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Advanced Wireless pH Testing for Laboratories
The Hanna HI9810402 HALO2 Wireless Refillable pH Tester for Lab represents the most refined generation of laboratory-grade pH testing technology. Designed for precision, durability, and convenience, it features a refillable glass body combined with a spherical glass sensing bulb, making it highly reliable for routine laboratory work. Integrating an open-source Bluetooth® module, this tester seamlessly communicates with the Hanna Lab App or existing Laboratory Information Management Systems (LIMS), offering specialists direct digital integration into their workflows. GLP-compliant data management ensures traceability with date and time stamping, allowing laboratories to maintain rigorous documentation standards. The compact, ergonomic form factor empowers professionals to conduct measurements on the bench or in the field without compromising accuracy. With precision down to ±0.02 pH and a broad measuring range from 0.00 to 14.00 pH, the HI9810402 positions itself as a professional tool built for scientific environments that demand both reliability and efficiency.
Unmatched Design and Build Quality Standards
The physical construction of the HI9810402 places durability and ease of maintenance at the forefront. Its IP65-rated casing protects the tester against dust and water jets, offering the resilience needed for busy laboratory benches or even semi-outdoor applications where splashes are unavoidable. The glass electrode body is easy to clean and resists the wear that can quickly degrade lesser designs. The spherical bulb tip, measuring 9 mm in diameter, ensures a generous surface area for stable and rapid readings, making it suitable for general aqueous solution measurements. Moreover, the refillable 3.5M KCl electrolyte system and double junction ceramic reference design significantly reduce electrode clogging and contamination from silver ions. This not only prolongs electrode lifespan but also sustains the accuracy of results over time. The HI9810402’s thoughtful build translates into reduced downtime, longer service intervals, and a total cost of ownership highly favorable for laboratories.
Comprehensive Features for Precision and Control
Beyond its durable structure, the HI9810402 offers advanced measurement features that meet and exceed laboratory demands. Automatic Temperature Compensation (ATC) and optional Manual Temperature Compensation (MTC) ensure readings remain accurate across the –5.0 °C to 80.0 °C range, with temperature resolution down to 0.1 °C. The built-in temperature sensor, located directly at the probe tip, captures immediate thermal data for correction without lag. Calibration options are flexible, supporting up to three points when used as a stand-alone meter or five points when paired with the Hanna Lab App. Automatic buffer recognition with both Hanna and NIST standard buffers enhances convenience and reliability, minimizing operator error. The meter’s ability to seamlessly display and log in mV extends flexibility for research applications beyond routine pH checking. In essence, the HI9810402 provides laboratory professionals the precision hardware and intelligent software tools to satisfy both routine QC and advanced research protocols.
Specific Applications in Modern Laboratory Work
In its targeted role for laboratory environments, the HI9810402 is ideally suited for a broad range of analytical and research tasks involving aqueous samples. Examples include routine quality control testing of beverages, monitoring chemical process conditions, verifying water treatment effectiveness, and ensuring culture media pH within microbiology facilities. Its spherical glass tip and compatibility with standard laboratory glassware make it a preferred choice for titration endpoint detection and buffer preparation. In environmental laboratories, it aids in determining sample suitability for aquatic life. Academic and educational research laboratories employ it for student practical work where repeatable precision is essential. In pharmaceutical and cosmetic labs, the HALO2 effectively handles the pH control critical in formulation and stability testing. These use-cases emphasize the HI9810402’s exceptional adaptability, reinforcing its status as a cornerstone instrument in diverse laboratory settings.
Seamless Connectivity and Data Integration Tools
The open-source Bluetooth® protocol of the HI9810402 is a standout feature that supports effortless connectivity to smart devices and data systems. With the Hanna Lab App, available for both Android and iOS platforms, the instrument transforms into a fully digital pH meter with functionalities like electrode condition monitoring, calibration reminders, customizable stability criteria, mV readout, alarm settings, and full GLP logs. The process of tagging a measurement with a single button press adds significant convenience, especially in workflows where data needs categorization for later analysis. This connectivity ensures that in both standalone and networked laboratory operations, results are consistently captured, securely stored, and easy to integrate into regulatory or quality documentation systems. The HI9810402 delivers not just on measurement performance but also on the efficiency and transparency of data handling.
User-Centered Experience and Operational Simplicity
Operational efficiency is integral to the HI9810402’s design. From unpacking to daily measurement, every step is intuitive. It is supplied with a comprehensive starter kit, including pH 4.01 and 7.01 buffers (20 mL sachets), electrode cleaning solution, storage solution, electrolyte refill solution, pipette, CR2032 lithium battery, and an instrument quality certificate. Calibration is simplified by allowing the probe to be inserted directly into Hanna buffer sachets, removing the need for intermediate containers and reducing contamination risks. A large, high-contrast LCD provides at-a-glance readings visible from any angle, and single-button operation reduces training requirements for new users. Maintenance is straightforward, with easy electrode refilling and cleaning procedures to preserve measurement reliability. Such user-focused features enable scientists to focus on their work rather than on instrument operation.
Reliability, Maintenance, and Long-Term Value
The HI9810402 is engineered for sustained performance under frequent use. Its refillable design and use of fresh buffers for each calibration session prolong electrode life while minimizing drift. The cleaning solution included is specifically formulated to remove grease and residue, maintaining optimal electrode responsiveness. Storage best practices are supported with supplied solutions that keep the pH glass hydrated, preventing premature electrode failure. Error messages clearly communicate when calibration buffers are invalid or when the battery needs replacement, thereby avoiding downtime due to undiagnosed issues. The tester’s long battery life — approximately 1000 hours (500 with Bluetooth enabled) — means fewer interruptions in lab activities. These attributes consolidate the HI9810402’s reputation as a dependable investment for labs seeking both immediate accuracy and long-term cost efficiency.
Global Availability via tpt24.com Excellence Assurance
For laboratories worldwide seeking the Hanna HI9810402 HALO2 Wireless Refillable pH Tester for Lab, tpt24.com stands as the leading global online store, offering guaranteed product authenticity, uncompromising quality, and reliable international delivery. Whether you operate in a high-end research facility in North America, a quality control lab in Europe, or an educational institution in Asia or Africa, tpt24.com ensures this precision instrument reaches you in perfect condition, backed by full manufacturer warranty. Their commitment to customer satisfaction is matched only by their logistical reach, delivering advanced laboratory solutions to any country with the same professionalism and efficiency. By sourcing from tpt24.com, you secure not just the equipment but the assurance of quality and performance that laboratories worldwide depend upon.
Specifications
| Specification | Detail |
|---|---|
| Model / SKU | HI9810402 |
| pH Range | 0.00 to 14.00 pH |
| pH Resolution | 0.01 or 0.1 pH |
| pH Accuracy | ±0.02 pH |
| mV Range | pH/mV conversion |
| mV Resolution | 0.1 or 1 mV |
| Temperature Range | –5.0 to 80.0 °C (23.0 to 176.0 °F) |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temperature Accuracy | ±0.5 °C / ±0.9 °F |
| Calibration | Up to 3 points (standalone) or 5 points (Hanna Lab App) |
| Temperature Compensation | Automatic (ATC) or Manual (MTC) |
| Electrode Body Material | Glass, High Temperature (HT) |
| Junction Type | Ceramic, double junction |
| Reference Cell | Ag/AgCl |
| Electrolyte | 3.5M KCl (refillable) |
| Tip / Shape | Spheric (Ø 9 mm / Ø 0.35 in.) |
| Outer Diameter | 12 mm (0.47 in.) |
| Length | 120 mm (4.7 in.) |
| Battery Type | 3V Lithium (CR2032) |
| Battery Life | ~1000 h (500 h Bluetooth on) |
| Environment | 0 to 50 °C (32 to 122 °F) |
| Casing Protection | IP65 |
| Dimensions | 51 × 206 × 21 mm (2.0 × 8.1 × 0.8 in.) |
| Weight | 60 g (2.1 oz.) |
| Included Accessories | pH buffers, cleaning/ storage solutions, refill electrolyte, pipette, battery, certificate, manual |