Hanna HI98318U GroLine Waterproof EC/TDS (ppm) Tester
- EC Range: 0.00–6.00 mS/cm
- Accuracy: ±2% Full Scale
- Battery Life: 250 Hours
- Waterproof with Graphite Sensor
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Modern Ergonomic Design for Nutrient Solution Testing
The Hanna HI98318U GroLine Waterproof EC/TDS (ppm) Tester represents the latest innovation in portable measurement technology for hydroponics and agriculture. Crafted with a slim profile of only 0.7 inches thick, its ergonomically optimized form comfortably fits in the palm, allowing for prolonged use without fatigue. The large, easy‑to‑read LCD display ensures that both EC (Electrical Conductivity) or TDS (Total Dissolved Solids) values and temperature are displayed clearly, along with indicators for calibration status, measurement stability, and battery health. By reducing the number of physical controls to just two buttons — one for power and one for calibration — Hanna Instruments has created a measurement tool that delivers advanced functionality with exceptional simplicity. The housing is waterproof by design, protecting internal electronics against moisture damage during routine use in demanding hydroponic environments, greenhouse operations, and agricultural field work.
Graphite Sensor Technology for Enhanced Measurement Stability
At the heart of the HI98318U is a graphite sensor technology that significantly reduces the polarization effect common in older amperometric testers equipped with stainless steel pins. This improvement leads to improved measurement accuracy and consistency over time, even when working with concentrated nutrient solutions that can cause interference in traditional probes. The exposed temperature probe ensures fast, automatic temperature compensation, stabilizing readings across a broad range from 0°C to 50°C (32°F to 122°F). Whether measuring low‑EC hydroponic setups or high‑nutrient concentrations, the instrument provides accurate conversion between EC and TDS via selectable factors of 0.5 (500 ppm) or 0.7 (700 ppm), catering to different industry and regional standards. This flexibility allows users to precisely monitor solution concentrations in either metric, ensuring optimal plant nutrient uptake and preventing deficiencies or toxicities.
Simplified Calibration Modes for Professional Reliability
Hanna Instruments ensures calibration is streamlined with the HI98318U by incorporating automatic single‑point calibration. Operators can perform calibration using either Quick Cal mode (with 5.00 mS/cm standard) or standard mode (with 1.41 mS/cm standard solution). The included Quick Cal solution sachets make setup instantaneous — simply immerse the sensor in the calibration solution, with the tester automatically detecting and adjusting to the correct standard. This design eliminates guesswork and minimizes human error, promoting reproducibility in measurements. For users engaging in frequent monitoring, especially in commercial crop production or research facilities, the ease of recalibration supports consistent data integrity over long periods of operation. Calibration indicators on the LCD, along with visual stability cues, guide users through the process, ensuring that the device remains accurate and trustworthy, even under heavy usage.
Dedicated Applications in Hydroponics and Plant Cultivation
The HI98318U GroLine Waterproof EC/TDS Tester is purpose‑built for hydroponic and agricultural applications, where precise nutrient management is essential. In hydroponics, EC measurement directly corresponds to fertilizer concentration, enabling growers to maintain optimal conditions for plant growth without over‑ or under‑feeding. In soil‑less cultures like aeroponics and aquaponics, accurate EC/TDS readings help adjust nutrient recipes for various plant life stages — from seedling establishment to fruiting. The waterproof design also makes the HI98318U ideal for measuring nutrient reservoir concentrations in outdoor gardens, greenhouse benches, or vertical farm setups. Moreover, horticulturists working in sensitive environments, such as seed germination chambers, can rely on the tester’s fast temperature response for immediate corrections. Plant nurseries, florists cultivating specialty blooms, and commercial produce farms all benefit from the device’s durability and accuracy, ensuring crops receive the right balance of dissolved minerals for premium yields.
Battery Efficiency Ensuring Continuous Operational Readiness
One of the standout operational features of the HI98318U is its extended battery life, delivering approximately 250 hours of continuous measurement on a single CR2032 Li‑Ion 3V cell. A low‑battery indicator notifies users proactively when power levels drop below 10%, while an automatic “dEAd bAtt” shutdown message preserves battery integrity. This power efficiency is particularly advantageous in field applications where access to spare batteries may be limited. The compact design of the battery compartment, accessible via a secure screw‑cap on the back of the unit, allows quick replacements without disrupting workflow. Hanna Instruments has engineered this tester to serve both commercial greenhouse managers and small‑scale growers by ensuring operational readiness throughout entire crop cycles, minimizing downtime and reducing maintenance intervals.
Precision Engineering Supporting Global Quality Standards
Every HI98318U unit ships fully configured with a protective storage cap, four HI50036 Quick Cal calibration sachets, one CR2032 battery, a detailed instruction manual, and a quality certificate verifying its compliance with Hanna Instruments’ strict quality assurance protocols. The tester’s accuracy levels — ±2% full scale for EC and ±0.5°C for temperature — meet the expectations of laboratory‑grade measurement tools, making it equally suitable for professional agronomists and advanced hobbyists. Precision engineering, combined with high‑quality materials, assures dependable performance across multiple crop types and nutrient systems. When integrated into daily irrigation management, the HI98318U prevents nutrient wastage and environmental runoff by accurately tracking the concentration of dissolved solids before plant feeding. This commitment to accuracy aligns with international agricultural measurement standards, ensuring global applicability for diversified cultivation practices.
Exclusive Worldwide Availability through tpt24.com Store
For buyers seeking guaranteed authenticity, precision, and worldwide delivery, tpt24.com stands as the premier online destination for the Hanna HI98318U GroLine EC/TDS Tester. As the leading global store for this model, tpt24.com ensures each unit is sourced directly from Hanna Instruments, backed by the manufacturer’s warranty and quality verification. Customers anywhere in the world receive their tester securely and promptly, with all included accessories intact and ready for use. Beyond product delivery, tpt24.com’s commitment includes responsive customer service, technical guidance on calibration procedures, and advice tailored to professional and hobbyist growers alike. The combination of genuine hardware, transparent quality assurance, and international logistics capability makes tpt24.com the trusted source for those who depend on accurate, real‑time nutrient monitoring to drive plant health and productivity.
Practical Advantages Driving Optimal Crop Performance
In practical use, the HI98318U offers a blend of portability, simplicity, and professional accuracy that directly benefits crop performance. By providing instant EC and TDS readings, growers can adjust nutrient feeding schedules without delay, preventing stress conditions and ensuring consistent growth rates. The waterproof build protects the tester during accidental immersion, while ergonomic handling supports extended operational sessions in large‑scale agricultural operations. The fast temperature compensation mechanism contributes to dependable results across different climatic conditions, from indoor grow tents to outdoor cultivation sites. Whether used daily in commercial greenhouses or weekly by home gardeners, the HI98318U adds measurable value to plant care routines by enhancing nutrient control, water quality assurance, and overall yield optimization.
Specifications
| Specification | Value |
|---|---|
| Model / SKU | HI98318U |
| EC Range | 0.00 to 6.00 mS/cm |
| EC Resolution | 0.01 mS/cm |
| EC Accuracy | ±2% Full Scale |
| Calibration | Automatic, single-point (1.41 mS/cm) |
| Temperature Compensation | Automatic, 0 to 50°C (32 to 122°F) |
| EC to TDS Conversion Factors | 0.5 (500 ppm) or 0.7 (700 ppm) |
| Temperature Accuracy | ±0.5°C / ±1°F |
| Battery Type | CR2032 Li-Ion 3V (1 pc) |
| Battery Life | Approx. 250 hours continuous use |
| Dimensions | 160 x 40 x 17 mm (6.3 x 1.6 x 0.7 in) |
| Included Accessories | Protective cap, (4) HI50036 sachets, CR2032 battery, manual, quality certificate |
| Waterproof | Yes |
| Sensor Material | Graphite |