KYORITSU AC CLAMP METER KEW 2007R
- Ergonomic one-hand operation
- True RMS 600/1000A auto-ranging
- CAT IV 300V safety standard
- Long-lasting AAA batteries
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
The Fully Safety Jaw: A New Standard
In the ever-evolving landscape of electrical engineering and maintenance, the demand for tools that combine precision with unwavering safety is at an all-time high. Professionals require instruments they can trust to provide accurate measurements in a variety of complex and high-stakes environments. The Fully Safety Jaw clamp meter is a testament to this need, representing a significant advancement in the field. This device is more than just a measurement tool; it is a meticulously engineered piece of equipment designed to enhance both the efficiency and, most importantly, the safety of the user. Its innovative features and robust construction make it the go-to choice for a wide spectrum of professionals, from industrial electricians to field service technicians, who prioritize performance and protection.
Ergonomics for Convenient One-Hand Operation
A tool’s design can be the difference between a quick, safe measurement and a risky, awkward one. The Fully Safety Jaw is distinguished by its ergonomic over-molded body, which is specifically crafted to provide a comfortable and secure grip. This thoughtful design allows for convenient one-hand operation, a feature that is invaluable when working in tight spaces, at a height, or while maneuvering around complex wiring. By enabling a user to hold the meter and perform the measurement with a single hand, the other hand is free to maintain balance, steady a lead, or operate other equipment. This reduction in the physical burden on the user not only minimizes fatigue during prolonged use but also significantly decreases the risk of accidents, making every measurement a safer and more efficient task.
Clear and Accurate Readings Every Time
Accuracy is the cornerstone of any reliable measurement device, and the Fully Safety Jaw excels in this regard. It features a large, easy-to-read display with 0.1A resolution, ensuring that every measurement is clear and immediately understandable. The meter provides accurate readings with True RMS capability, a critical feature for modern electrical systems that often contain non-linear loads, which can distort waveforms. True RMS measures the effective heating power of a signal, providing a far more accurate result than meters that only measure the average value. Its 600/1000A auto-ranging function automatically selects the appropriate measurement scale, eliminating the need for manual adjustments and preventing potential user errors. This combination of high-resolution display, True RMS accuracy, and auto-ranging functionality ensures that professionals can trust the data they are seeing, making for confident and precise diagnostics.
Multipurpose Functionality for Diverse Applications
The versatility of the Fully Safety Jaw makes it an essential tool across numerous industries. Electricians can use it to troubleshoot circuits, measure the current draw of motors and appliances, and verify the integrity of power distribution systems. In the automotive industry, technicians rely on it to diagnose electrical faults, test battery performance, and check the output of charging systems. HVAC (Heating, Ventilation, and Air Conditioning) professionals find it indispensable for measuring the current consumption of compressors and fans, which is crucial for identifying potential issues before they lead to a system failure. The meter’s ability to measure AC and DC voltage, resistance, and continuity means it can replace multiple single-function tools, making it a comprehensive and space-saving solution for any professional’s toolkit.
Specialized Uses of the Safety Jaw
Beyond its general applications, the Fully Safety Jaw is particularly well-suited for several specific tasks. In industrial settings, it can be used for non-invasive load testing of machinery and circuits, allowing maintenance teams to monitor performance without shutting down operations. Its high safety ratings make it ideal for use in control panels and on service entrance equipment. The continuity buzzer is a standout feature for cable installers and repair technicians, who can quickly and audibly check for open or short circuits in wiring. Furthermore, its ability to measure AC voltage up to 600V with high accuracy makes it perfect for checking for proper phase balance in three-phase systems. The combination of these features in a single, reliable device provides professionals with a powerful tool for a wide array of specialized diagnostic challenges, saving both time and effort.
Extended Battery Life for Uninterrupted Work
The reliability of a tool is directly tied to its operational longevity, and the Fully Safety Jaw is designed for endurance. Powered by two standard R03/LR03 (AAA) batteries, it offers an impressive continuous measuring time of approximately 170 hours. This exceptional battery life means professionals can go for extended periods without needing to replace the batteries, a crucial factor when working on long projects or in the field where power sources are scarce. To further conserve energy, the meter includes an auto power save feature that automatically shuts down the device after approximately 10 minutes of inactivity. This intelligent power management ensures that the meter is always ready when you need it, minimizing downtime and the hassle of frequent battery maintenance.
Adherence to the Highest Safety Standards
Safety is not an optional extra; it is the cornerstone of the Fully Safety Jaw’s design. The meter is built to meet the most stringent international safety regulations, including IEC 61010-1 CAT Ⅳ 300V / CAT Ⅲ 600V. This compliance means the meter is engineered to safely withstand high transient voltages and is suitable for use in high-energy environments like industrial distribution systems and service entrances. It also adheres to IEC 61010-031, IEC 61010-2-032, and IEC 61010-2-033, which specify safety requirements for test leads and other accessories. Furthermore, its IEC 61326-2-2 (EMC) compliance guarantees that the meter operates without being affected by or causing electromagnetic interference, while its IP40 rating provides protection against solid objects. This unwavering commitment to safety gives professionals the confidence to perform their work without fear.
The Premier Global Store for Quality
When it comes to purchasing a professional-grade tool like the Fully Safety Jaw clamp meter, authenticity and quality are paramount. The tpt24 online store is the world’s leading online destination for this exceptional product. Tpt24 has earned its reputation by providing a guarantee of authenticity and quality with every sale. As the top online retailer, they ensure that the product you receive is genuine and meets all the specified standards. Furthermore, tpt24 offers worldwide delivery, meaning that no matter where you are located, the Fully Safety Jaw can be delivered directly to you with a guarantee of its origin and performance. By choosing tpt24, you are not only acquiring a superior measurement tool but also gaining the peace of mind that comes with a trustworthy and reliable purchasing experience.
Specifications
| AC A | 600.0/1000A (Auto-ranging) ±1.5%rdg±4dgt [45 to 65Hz] ±2.0%rdg±4dgt [40 to 400Hz] |
|---|---|
| AC V | 600.0V ±1.2%rdg±3dgt [45 to 65Hz] ±1.5%rdg±4dgt [40 to 400Hz] |
| DC V | 600.0V ±1.2%rdg±3dgt |
| Ω | 600.0Ω/6.000kΩ (Auto-ranging) ±1.3%rdg±5dgt (600Ω) ±2.0%rdg±3dgt (6.000kΩ) |
| Continuity buzzer | 600Ω (Buzzer sounds below 90Ω) |
| Conductor size | φ33mm max. |
| Applicable standards | IEC 61010-1 CAT IV 300V / CAT III 600V Pollution degree 2 IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033, IEC 61326-2-2(EMC), IEC 60529 IP40, EN 50581(RoHS) |
| Power source | R03/LR03 (AAA) (1.5V) × 2 |
| Continuous measuring time | Approx.170 hours (when R03 is used) (Auto power save : Approx. 10 minutes) |
| Dimension | 204(L) × 81(W) × 36(D)mm |
| Weight | Approx. 220g (including batteries) |
| Accessories | 7066A (Test leads) 9079 (Carrying case) R03 (AAA) × 2, Instruction Manual |