KYORITSU FORK CURRENT TESTER KEW 2300R
- True RMS for accurate readings
- Non-Contact Voltage function
- Zero adjustment for DC current
- Auto Power Off
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
1. The Dawn of Safe and Accurate Measurement
In the world of electrical diagnostics, precision and safety are not just features; they are non-negotiable requirements. This advanced clamp meter represents a new dawn in safe and accurate measurement, combining innovative safety functions with high-resolution readings in a compact and lightweight design. It’s a tool engineered for professionals and enthusiasts who demand reliability and precision in their work. The device’s thoughtful design and commitment to user safety make it an indispensable partner for anyone who works with electrical circuits, from troubleshooting in tight spaces to performing routine maintenance.
2. True RMS: Precision in a Complex World
Modern electrical systems are often characterized by distorted and non-sinusoidal waveforms, which can be caused by devices like variable-speed drives and switching power supplies. A standard multimeter that measures the average value of an AC signal can provide highly inaccurate readings in these conditions. This clamp meter, however, features True RMS reading, which is an essential feature for accurate measurement. By calculating the true root-mean-square value of the signal, it provides a precise representation of the electrical power, regardless of the waveform’s shape. This is a critical feature for anyone working in industrial automation, HVAC, or modern electronics, where an accurate reading is the foundation of any effective diagnosis.
3. Non-Contact Voltage for Enhanced Safety
Safety is the paramount concern when working with live electrical circuits. This clamp meter addresses this with a key safety function: Non-Contact Voltage (NCV). This feature allows the user to detect the presence of AC voltage without making direct contact with a wire or terminal. During voltage detection, the meter provides a clear warning with an audible signal and a flashing “Hi” on the display. This “early warning system” significantly reduces the risk of accidental shock and helps technicians identify live circuits from a safe distance. This is a critical feature for both seasoned professionals and beginners, as it provides an extra layer of protection and peace of mind.
4. Zero Adjustment for Perfect DC Readings
Accurate DC current measurement can sometimes be a challenge due to small offsets or residual magnetic fields. This clamp meter solves this problem with its zero adjustment function, which is possible at the push of a button. Before a measurement is taken, the user can press the button to zero out any residual readings, ensuring that the final measurement is as accurate as possible. This is particularly useful for measuring small DC currents, such as those found in automotive electrical systems or low-power electronics. This simple yet powerful feature eliminates a common source of error and ensures that the readings are reliable and precise.
5. Applications in a Wide Array of Fields
The compact size and versatile features of this clamp meter make it uniquely suited for a wide variety of applications. For electricians, its small clamp size (Max φ10mm) is perfect for working inside crowded junction boxes or diagnosing issues in residential circuit panels. The NCV function is invaluable for safely identifying live wires before work begins. In the automotive industry, its ability to measure both AC and DC current with a high resolution (0.1A minimum resolution) makes it an ideal tool for diagnosing parasitic battery drains, testing the output of an alternator, or checking the current draw of individual fuses. For HVAC technicians, it’s a great tool for checking the current draw of motors and controls in compact units.
6. High Resolution and Compact Design
This clamp meter strikes a perfect balance between high-resolution measurement and a compact, portable design. With a maximum digit display of 1,049 and a minimum resolution of 0.1A, it provides precise and detailed readings for both AC and DC current up to 100A. The device’s compact dimensions (161x40x30mm) and light weight (110g) make it exceptionally portable and easy to carry in a pocket or a small tool bag. The included carrying case, the 9113, ensures that the meter and its accessories are protected during transport and storage, making it an ideal companion for field technicians who are constantly on the move.
7. Power Efficiency for Extended Use
For technicians working in the field, long battery life is a crucial factor. This clamp meter is designed with power efficiency in mind. It is powered by two standard R03 (AAA) batteries, which are inexpensive and widely available. The device offers an impressive continuous measuring time of approximately 46 hours for AC current and 52 hours for DC current. The Auto Power Off function, which activates after about 10 minutes of inactivity, further extends battery life and ensures that the device is always ready when you need it. This combination of a convenient power source, long battery life, and an auto-off function makes the device a practical and user-friendly tool for any professional.
8. An Indispensable Tool for Modern Diagnostics
In conclusion, this advanced clamp meter is an indispensable tool for anyone working with modern electrical systems. Its True RMS capability ensures accurate measurements of distorted waveforms, while its NCV function provides a critical layer of safety. The zero adjustment for DC current, along with its high resolution and compact design, makes it a powerful and versatile instrument. The device is built with a strong emphasis on safety and portability, complying with the IEC 61010-1 CAT III 300V standard. With its user-friendly design and powerful features, this clamp meter is a reliable and essential partner for any professional facing the challenges of today’s complex electrical landscape.
Specifications
| Current measurement | AC A 0 to 100.0A ±2.0%rdg±5dgt [50/60Hz] DC A 0 to ±100.0A ±2.0%rdg±5dgt |
|---|---|
| Crest factor | 2.5 |
| Non contact voltage | Detect AC voltage without contacting with socket wire. During voltage detection, “Hi” flashes and a buzzer sounds. |
| Maximum digit | 1,049 |
| Conductor size | Max φ10mm |
| Safety Standard | IEC 61010-1 CAT III 300V Pollution degree 2 |
| Power source | R03 (AAA)(1.5V)× 2 (Auto power off: Approx.10 minutes) *Continuous measuring time: AC A Approx. 46 hours, DC A Approx. 52 hours |
| Dimension | 161(L) × 40(W) × 30(D)mm |
| Weight | 110g (including battery) |
| Accessories | 9113 (Carrying Case) R03 (1.5V) × 2 Instruction Manual |