KYORITSU MULTI FUNCTION INSTALLATION TESTER MODEL 6018
- Insulation Test Voltages: 250V, 500V, 1000V
- Earth Resistance: 12/120/1200Ω
- AC Voltage: 0 to 600V
- Safety Rating: CAT III 600V
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
A Comprehensive Tool for Electrical Safety
In the demanding world of electrical work, safety and accuracy are paramount. This multipurpose instrument is a testament to that principle, designed to provide comprehensive testing capabilities for a variety of applications. It is engineered to perform insulation resistance testing, earth resistance measurement, and AC voltage testing with precision and ease. Its robust design is built to meet the rigorous safety standard of IEC 61010-1 CAT III 600V, ensuring that it can be used confidently in a wide range of electrical environments. The device’s color-coded scales and a clearly marked range switch make it incredibly user-friendly, allowing for quick and easy reading of measurements. This instrument is not just a tool; it’s a critical piece of safety equipment for any electrician or maintenance technician.
Enhanced Insulation Testing for Reliability
The core functionality of this device lies in its insulation resistance testing capabilities. It offers multiple test voltages—250V, 500V, and 1000V—allowing professionals to test a wide range of electrical systems and components, from residential wiring to industrial motors. Insulation resistance is a critical measure of the health of an electrical system; a high reading indicates that the insulation is effectively preventing current leakage, which is essential for both safety and performance. The inclusion of a test lead with a remote control switch is a significant convenience feature, enabling users to operate the device with a single hand while keeping the other hand free to steady themselves or hold a probe in a hard-to-reach area. This feature, combined with the automatic warning for auxiliary earth spike resistance, ensures reliable and accurate test results every time.
Specialized Applications in Electrical Work
The versatility of this tester makes it suitable for a diverse range of applications. For example, it is indispensable for verifying the insulation on new electrical installations to ensure they meet safety codes. It’s also a go-to tool for troubleshooting insulation faults in older wiring and equipment, helping technicians pinpoint potential hazards. In industrial settings, it’s used for preventive maintenance on electric motors and transformers, where regular insulation testing can prevent costly failures and extend equipment life. Furthermore, its ability to measure earth resistance makes it a vital tool for checking the integrity of grounding systems, which are essential for dissipating fault currents and protecting people from electric shock. The simplified precision measurement method allows for efficient and accurate testing of grounding systems.
Designed for Efficiency and User Comfort
The design of this instrument prioritizes the user experience. The integrated backlight function ensures that the display is readable even in poorly lit environments, such as basements or electrical closets. A thoughtfully designed shoulder strap allows the device to be hung around the neck, freeing up both hands for operating the test leads. This simple yet effective feature is particularly useful when working at heights or in confined spaces. The inclusion of color-coded scales and range switch positions reduces the risk of user error by providing a clear and intuitive visual guide. The automatic warning for auxiliary earth spike resistance provides an added layer of confidence in the accuracy of earth resistance measurements, alerting the user if the test conditions are not optimal.
Reliable Earth Resistance and AC Voltage Measurement
In addition to insulation testing, the device excels at measuring earth resistance and AC voltage. Its simplified precision measurement method for earth resistance offers three ranges—12Ω, 120Ω, and 1200Ω—providing the flexibility needed for various grounding systems. An accurate earth resistance reading is fundamental to ensuring the effectiveness of a building’s grounding system. The ability to measure AC voltage from 0 to 600V is a crucial complementary function, allowing technicians to safely verify the presence of live voltage before performing any tests. The device can also measure earth voltage up to 60V AC, which helps in identifying potentially hazardous conditions in the ground.
Meeting the Highest Standards of Safety
The safety of the user is paramount, and this tester is built with that in mind. It is designed to meet not only the IEC 61010-1 CAT III 600V standard but also a range of other critical safety and performance standards, including IEC 61010-2-034, IEC 61010-2-031, and IEC 61557. The CAT III 600V rating signifies that the device is safe for use on distribution-level electrical circuits, such as those found in fixed installations. The robust construction and high-quality materials ensure long-term reliability and protection against electrical hazards.
Technical Specifications for the Professional
The technical specifications of the device showcase its professional-grade design. It is powered by eight standard LR6 (AA) batteries, making it easy to power and maintain. Its dimensions of 130mm (L) x 183mm (W) x 100mm (D) and a weight of approximately 1000g make it a portable yet substantial tool that feels solid in hand. The comprehensive set of included accessories, such as the remote control switch test leads, alligator clips, and a shoulder strap, ensures that the user is fully equipped for a variety of testing scenarios right out of the box.
Specifications
| Insulation Testing | ||
|---|---|---|
| Test Voltage | 250V/50MΩ 500V/100MΩ 1000V/2000MΩ |
|
| Accuracy | ±5%rdg | |
| Earth Resistance | ||
| Simplified Precision measurement |
12/120/1200Ω | |
| Accuracy | ±3% of full scale value | |
| AC Voltage | ||
| 0 to 600V AC | ±3% of full scale value | |
| Earth Voltage | ||
| 0 to 60V AC | ±3% of full scale value | |
| Applicable Standard | IEC 61010-1 CAT Ⅲ 600V Pollution Degree 2, IEC 61010-2-034, IEC 61010-2-031 IEC 61557 | |
| Power source | LR6 (1.5V) × 8 | |
| Dimension | 130(L) × 183(W) × 100(D)mm | |
| Weight | Approx. 1000g | |
| Accessories | 7103A (Test leads with remote control switch) 7131B (Safety alligator clips [black]) 7161A (Flat test prod [black]) 8017 (Extension prod long) 9092 (Cord case) 9121 (Shoulder strap) R6 (AA) × 8, Instruction Manual |
|
| Optional Accessories | 7095A (Earth resistance test leads) 7150A (Test leads with remote control switch set) 7245A (Precision measurement Cord Set) 8016 (Hook type prod) |
|