Megger CDAX 605 capacitance and dissipation factor measuring instrument
- Capacitance accuracy ±0.02%
- Dissipation factor accuracy ±0.002%
- Test current capacity 5 A
- Weight only 4.4 kg
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Introducing Megger CDAX 605 Precision Excellence
The Megger CDAX 605 is a high-precision capacitance and dissipation factor measuring instrument designed to meet the rigorous demands of modern electrical diagnostics and calibration. Engineered for ultimate versatility, it supports capacitive, resistive, and inductive test objects, delivering unmatched accuracy in measurements without the need for complex balancing or recalculation. Combining both bridge and direct vector measurement techniques, it stands out as a reliable solution for laboratory, production line, and demanding field environments. Compact and lightweight at just 4.4 kg, the CDAX 605 offers a fast, automated measurement process while maintaining an exceptional accuracy of ±0.02% for capacitance and ratio measurements. Whether for routine insulation quality verification or in-depth testing of advanced equipment, the CDAX 605 guarantees dependable, repeatable results under a diverse range of testing conditions, seamlessly integrating with any standard reference capacitor or resistor.
Advanced Technology Behind Measurement Superiority
At the heart of the CDAX 605 lies its unique combination of bridge and direct vector measurement capabilities. This advanced technology enables accurate measurement of capacitive, resistive, or inductive loads with direct readings of capacitance, dissipation factor, inductance, and ratio — eliminating the tedious process of balancing and recalculation required by traditional test methods. It caters to all standard UST (Ungrounded Specimen Test) and GST (Grounded Specimen Test) configurations, including UST-R, UST-B, UST-RB, GST-GND, GSTg-R, GSTg-B, and GSTg-RB. Furthermore, its measurement precision is maintained through advanced calibration systems that automatically balance the device at any operating temperature within the specified range, ensuring top-tier performance in challenging environments. With a measurement range from 5 Hz to 400 Hz and the ability to handle up to 5 A test current, the instrument sets a new standard for flexibility and capability in insulation diagnostic tools.
Versatile Applications Across Multiple Electrical Domains
The CDAX 605 finds applications across a broad spectrum of industries and testing environments, serving critical roles in the diagnosis, commissioning, and maintenance of high-voltage equipment. It is invaluable in testing power transformers, high-voltage cables, bushings, capacitor banks, and various insulating materials. Additionally, it is used in the precision calibration of Capacitive Coupling Voltage Transformers (CCVTs) and other high-ratio measurement devices — a task for which traditional capacitance bridges struggle due to their inability to handle the small capacitances in the 100–1000 pF range under high ratios. In manufacturing environments, the CDAX 605 ensures consistent product quality by detecting insulation imperfections before products leave the production line. In field conditions, it supports non-destructive condition monitoring, enabling decision-makers to trend equipment performance over time and schedule preventive maintenance before costly failures occur.
Seamless Integration with High Voltage Sources
One of the defining strengths of the CDAX 605 is its capability to function as part of a complete insulation testing system when paired with a high-voltage AC source and a standard capacitor. In such configurations, the high-voltage source energizes the test object, the standard capacitor serves as the reference, and the CDAX 605 processes the resultant measurement currents with exceptional accuracy, even at elevated potential differences. Thanks to its design, the CDAX 605 imposes no restrictions on test voltage beyond the limits of the connected power source and standard capacitor. It is compatible with reference resistors as well, offering expanded measurement configurations for devices that respond better to resistive testing methods. The instrument’s adaptability ensures that users can customize their test setups for both standard and highly specialized testing needs, giving it a crucial edge in research, manufacturing, and utility environments.
Optimized User Interface for Measurement Efficiency
Usability is central to the CDAX 605’s design, featuring an intuitive graphical user interface accessible through both standard PCs and touch-screen devices. The bundled CDAX Control software offers comprehensive features such as test parameter entry, live voltage and current monitoring, capacitance and dissipation factor calculation, inductance measurement, power factor determination, and data logging functions. This interface allows operators to store results for later comparison, facilitating long-term trend analysis of critical equipment. Furthermore, CDAX Control includes high-resolution visual outputs for waveform analysis, providing oscilloscope-like inspection during tests. The ability to interface with industry-standard automation systems through optional LabView and C# libraries expands its integration potential into automated quality control lines or advanced research stations, making it a multifunctional solution in both static and portable contexts.
Engineering for Rugged and Reliable Operation
Built to perform across a wide range of environmental conditions, the CDAX 605 operates efficiently in temperatures from -20°C to +55°C and can be stored in extremes from -40°C to +70°C. Its rugged build ensures stable operation in high-voltage test rooms, laboratories, substations, and industrial environments with up to 90% non-condensing humidity. Compliance with CE marking standards for Low Voltage Directive (LVD), Electromagnetic Compatibility (EMC), and RoHS environmental restrictions reflects its adherence to global safety and sustainability requirements. Secure connections are made via its multiple input options including UHF connectors, LEMO 3S, and UHF-to-BNC adapters. These design choices ensure operational integrity under the most demanding conditions while providing the adaptability required for varied international use cases.
Trusted Worldwide Through tpt24 Global Distribution
When it comes to sourcing the Megger CDAX 605 with guaranteed authenticity and quality, tpt24 stands as the undisputed leader in the online marketplace. Recognized globally for its commitment to delivering only original, factory-certified instruments, tpt24 ensures that every CDAX 605 is shipped with full warranty coverage. Whether you are located in Europe, Asia, Africa, or the Americas, tpt24 offers worldwide delivery, ensuring you receive your precision equipment wherever your operations may be. Their expert technical support team provides pre-sale consultation, post-sale guidance, and operational training to help customers maximize their return on investment. This combination of genuine Megger products, competitive pricing, and unmatched customer care solidifies tpt24’s status as the premier online distributor for the CDAX 605 and other advanced testing equipment.
Technical Mastery and Long-Term Measurement Assurance
The technical excellence of the CDAX 605 extends beyond raw performance to include the long-term stability and reliability that industrial and utility sectors demand. Automatic balancing calibration ensures accurate measurements at any permissible operating temperature, with a recommended calibration cycle of only once every two years — a testament to its long-term stability. Its impressive measurement resolution — 0.001 pF for capacitance, 0.1 mH for inductance, and a dissipation factor resolution of 1×10^-6 — allows for precise detection of even the smallest changes in insulation condition. A warm-up time of just 15 minutes ensures swift readiness for testing, while a selectable measurement duration (default 2 seconds) provides flexibility between speed and statistical accuracy. With these engineering qualities, the CDAX 605 delivers consistent, dependable measurement performance for years, establishing itself as the instrument of choice for professionals who refuse to compromise on accuracy.
Specifications
| Specification | Value |
|---|---|
| Measurement Type | Capacitance and dissipation/power factor |
| Capacitance Range | > 1 pF |
| Dissipation Factor Range | 0 – 100 |
| Inductance Range | < 1000 kH |
| Test Frequency Range | 5 – 400 Hz |
| Test Voltage | Unlimited (limited by reference object) |
| Test Current | 0 – 5 A (extendable with transformer) |
| Capacitance Accuracy | ±0.02% (15 µA to 5 A) |
| Dissipation Factor Accuracy | ±(0.05% of reading + 0.002%) |
| Ratio Accuracy | ±0.02% |
| Phase Accuracy | ±0.02 mRad |
| Voltage/Current Accuracy | ±0.1% of reading |
| Maximum Resolution – Capacitance | 0.001 pF |
| Maximum Resolution – Inductance | 0.1 mH |
| Maximum Resolution – DF | 1 × 10⁻⁶ |
| Maximum Resolution – Phase | 1 × 10⁻⁶ |
| Measurement Channels | 2 |
| Inputs | Cn, Cx1, Cx2, Ground |
| Connectors | UHF, LEMO 3S, UHF–BNC adapter |
| Operation Temperature | -20°C to +55°C |
| Storage Temperature | -40°C to +70°C |
| Humidity | < 90% RH, non-condensing |
| Supply Voltage | 100 – 240 V AC, 50/60 Hz |
| Power Consumption | 60 VA max |
| Dimensions (Instrument) | 335 × 300 × 99 mm |
| Weight | 4.4 kg |
| Software Interface | CDAX Control, optional LabView/C# |
| Calibration Interval | 2 years (recommended) |
| Warm-up Time | 15 minutes |
| Measurement Time | Default 2 seconds/selectable |