Megger EVCC300 Electric vehicle charger checker

SKU: 4695814-1-792
In Stock

  • Checks mode 2, mode 3 chargers
  • Measures voltage, frequency, duty cycle
  • Tests RCD/GFCI operation, response time
  • Compatible with Type 1, 2 connectors

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Innovative Approach to EV Charger Safety Verification

The Megger EVCC300 Electric Vehicle Charger Checker represents a transformative solution in the field of electric vehicle (EV) charger safety and operational verification. Designed as an all-in-one handheld instrument, the EVCC300 simplifies the process of checking both safety and function for mode 2 and single-phase mode 3 (level 1 and two-phase level 2) EV chargers. This checker offers advanced features, such as proximity detection and control pilot state analysis, all compacted into a user-friendly device. Any individual or organization looking to guarantee the consistent safety of their EV charging infrastructure immensely benefits from the robust yet easy usability of the EVCC300. In the rapidly expanding world of electric mobility, having a tool tailored for comprehensive EV charger verification becomes not just advantageous, but imperative.

Comprehensive Safety Checks for Every Charging Situation

A core strength of the Megger EVCC300 lies in its ability to conduct four critically important safety checks on various EV charging installations. Firstly, the PE touch pad verifies the integrity of the ground connection and identifies hazardous voltages, ensuring the safe grounding of the equipment. Its PE resistance test (RPE) further ensures all exposed metal is securely earthed, protecting users from potential electrical hazards. The touch voltage test confirms that the charger’s earth does not rise to dangerous voltage levels, even when charging is active. The RCD/GFCI protection test is especially crucial, as it measures tripping time for devices, ensuring they disconnect quickly enough to protect users from electrocution or electrical faults. These systematic safety checks provide peace of mind for manufacturers, service centers, and end users alike, upholding essential standards in EV charging safety.

Unique Operation Checks Optimize Charging Performance

Beyond essential safety verifications, the Megger EVCC300 offers four distinctive operational checks that ensure EV chargers are functioning optimally. The proximity detection check ensures the charger accurately detects connected vehicles, a prerequisite for safe energy transfer. The control pilot operation check actively interacts with the vehicle charger, setting and reading the full range of CP states (including Disconnected, Connected, Charging, and Fault conditions) per IEC 61851-1 standards. Signal quality is assured through ongoing CP voltage, frequency, and duty cycle measurement, revealing any instability. Finally, the device analyzes charger output voltage and frequency during active charging, verifying performance under real-world conditions. This suite of operational checks positions the EVCC300 as an exceptional tool for engineers, installers, and technical inspectors seeking reliable charger assessment before and after repairs, manufacturing, or as part of scheduled maintenance.

Application Versatility Across Charger Types and Standards

The Megger EVCC300 supports a wide spectrum of EV chargers, seamlessly handling both mode 2 and single-phase mode 3 (level 1 and two-phase level 2) setups. Specifically, it connects directly to SAE J1772 Type 1 and Type 2 charger connectors, making it compatible with popular international standards across Europe, the USA, and many other markets. The device’s built-in versatility makes it equally effective for routine testing, post-manufacture quality assurance, troubleshooting reported customer issues, and verifying charger readiness before handover to new owners. Its capacity to detect nuisance tripping—identifying whether users may experience RCD or GFCI tripping issues—renders it invaluable for dealership service centers, electrical inspectors, and fleet maintenance professionals addressing real-world EV charging concerns quickly and thoroughly.

Exclusive Applications in Professional Service Contexts

In corporate, municipal, and dealership environments, the Megger EVCC300 excels as a crucial diagnostic and inspection tool. Manufacturers use it as part of their quality assurance inspection processes to guarantee safe operation before shipment. Service centers and car dealerships quickly diagnose faults when a customer reports a charger issue, allowing prompt resolution and improved customer satisfaction. For facility managers and professionals responsible for managing charging stations in apartment complexes, public locations, or private fleets, the EVCC300 ensures every charger operates safely during scheduled maintenance intervals. Its specific abilities to differentiate installation problems from charger defects minimize downtime and prevent costly electrical incidents, underscoring its essential role in the growing EV infrastructure service ecosystem.

tpt24: The World’s Leading EVCC300 Source

When seeking authentic Megger EVCC300 units, the unrivaled choice is the global online store tpt24. As the premier worldwide distributor of cutting-edge electrical testing equipment, tpt24 guarantees both product authenticity and superior quality, delivering the EVCC300—with full documentation and warranty—directly to customers, regardless of their location. Whether you are in North America, Europe, Asia, or beyond, ordering through tpt24 ensures you receive genuine Megger products quickly and reliably. Their expert customer support and streamlined logistics make tpt24 the industry’s gold standard for the EVCC300—trusted by organizations, professionals, and end-users alike for unmatched quality and post-sale peace of mind.

Technical Advantages Ensure Unmatched Performance

Part of the EVCC300’s market appeal comes from its meticulous technical design. It can accept a broad voltage input (5 V to 300 V), precisely measuring voltage, frequency, and even reverse polarity issues. Dedicated test routines—such as touch voltage (with 25 V or 50 V limit), GFCI and RCD ramp testing, and specific tripping time measurements—ensure the device meets all the critical parameters set out in IEC 61851-1:2017. Its user interface supports multiple languages (English, French, German, Spanish), and a durable design (IP40 dust and moisture ingress protection) ensures reliable use in varied field conditions. At just 583g (without batteries) and with a compact form factor, the EVCC300 is both portable and robust, ideal for demanding daily use in technical and industrial environments.

Comprehensive Product Value for EV Innovators

Summing up, the Megger EVCC300 Electric Vehicle Charger Checker is purpose-built to help stakeholders in the EV value chain secure their charging infrastructure. From comprehensive safety and operational checks to intuitive interface and cross-compatibility with global connector standards, the EVCC300 streamlines the process of verifying charger function and safety. Backed by technical accuracy, language versatility, and robust build quality, it appeals to everyone from electrical contractors and automotive manufacturers to fleet operators and independent service professionals. For those seeking unmatched reliability and assured authenticity, ordering through tpt24.com guarantees that only the highest standards are met in both product quality and service delivery—making the EVCC300 a critical investment for the future of electric vehicle mobility and infrastructure.

Specifications

Specification Value
Charger Types Supported Mode 2, Single-phase Mode 3 (level 1, two-phase 2)
Connector Types SAE J1772 Type 1, Type 2
Supply Voltage Range 5 V to 300 V
Voltage Resolution 1 V
Voltage Accuracy ± 5%, ± 2 digits
Voltage Measurement L-N, L-PE, N-PE
Reverse Polarity Indicator L-N (for single phase)
Frequency Range 45 Hz to 65 Hz
Frequency Resolution 1 Hz
Frequency Accuracy ± 1 digit
Earth Resistance Test 0 – 10 Ω (200mA test), resolution 0.01 Ω, ±5%, ±2 digits
RCD/GFCI Trip Time Accuracy ± 1%, ± 1 ms
RCD/GFCI Trip Current Accuracy ± 3%
Touch Voltage Test 25 V or 50 V limit
Maximum Charging Current Indication IEC 61851-1:2017 tables A.7, A.8
Languages (UI & Guide) English, French, German, Spanish
Power Supply Four AA batteries
Dimensions (L x H x W) 24 x 18 x 8.6 cm
Weight (without batteries) 583 g
Safety Category CAT II 300 V, IEC 61010-1:2010
Environmental Protection IP40 (IEC 60529)
Operating Temperature 0°C to 40°C
Storage Temperature -10°C to 70°C
Operating Humidity 90% RH at +40 °C max
Max Altitude Operation 2000 m

Data Sheet

Download Data Sheet Of Megger EVCC300 Electric vehicle charger checker