Megger LRCD200 series Combined loop and RCD testers

SKU: 4695814-1-681
In Stock

  • Non-trip loop test function.
  • RCD test range: 10–1000 mA.
  • Weatherproof tough rubber case.
  • Automatic RCD test recall.

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Advanced Testing Solutions for Electrical Professionals Globally

The Megger LRCD200 series Combined Loop and RCD Testers represent a remarkable leap forward in portable, efficient, and professional-grade testing gear for electrical safety and certification. Designed for electrical contractors and maintenance engineers around the world, these instruments streamline the testing process of energised circuits by integrating non-trip loop and residual current device (RCD) testing into a single, robust unit. The LRCD200 family addresses both practical site needs and demanding safety regulations, making it suitable for a diverse range of commercial, industrial, and domestic electrical installations. With three distinct models—LRCD200, LRCD210, and LRCD220—users can select the precise functionality required for their region and application, ensuring maximum testing reliability and flexibility.

Rugged Construction and User-Centric Functional Design

All instruments in the LRCD200 series are built to withstand the physical rigors of harsh job sites. Each device comes encased in Megger’s new electricians tester case, which features tough rubber armoring for superior drop and impact resistance, a built-in protective front cover to safeguard critical components, and weatherproofing to the respected IP54 standard. Whether hanging around the neck, held during a test, or placed on a workbench, the testers are engineered for non-slip stability and comfort. Conveniently, test leads can remain attached even when the protective cover is open or closed, allowing for rapid deployment and enhanced productivity. The ergonomic design underscores ease of use, permitting extended operation without fatigue.

Powerful Application Range and Exclusive Use Cases

The LRCD200 series is noted for its wide-ranging applications, making it indispensable for a variety of electrical installations and maintenance activities. The testers are explicitly designed for use in live circuits where non-tripping loop testing is critical, especially in settings protected by RCDs. Electrical contractors find the LRCD200 indispensable for commissioning new electrical systems, routine inspection and diagnostics in residential, commercial, and industrial environments, and final safety certification checks before handover to clients. The LRCD210 is ideal for domestic installers who need to conform to stringent UK Part P requirements. The LRCD220 adds two-wire fast testing, phase-to-phase, and phase-to-earth measurements, making it an unrivaled choice for more advanced industrial setups, large public venues, or complex panel systems where both versatility and rapid data recall are vital.

Advanced Safety Features for Peace of Mind

Safety is paramount in the design and function of the LRCD200 series. Their non-trip loop testing ensures that RCDs rated 30 mA or greater will not be inadvertently tripped during testing—this extends even to sensitive electronic RCDs. The testers signal L-N-E connection status and reverse polarity with intuitive LEDs to prevent testing errors. All models comply with international safety standards (IEC 61010 Cat III 300 V, EN61557), and include selectable touch voltage limits (25 V or 50 V), providing additional layers of protection against inadvertent contact with hazardous voltages. The tough, weather-resistant case and robust internal build grant reliability for both indoor and challenging outdoor work, while the built-in cover further guards against accidental damage and dust or water ingress.

Flexible Product Variants for Global Markets

A major strength of the LRCD200 series is its adaptability for use in various global regions and electrical systems. The base LRCD200 model supports three-phase safe, non-trip loop testing and RCD testing (from 10 mA to 500 mA) but is not suitable for UK compliance. The LRCD210 extends functionality with 1/2I, I, and 5I RCD testing—capable of verifying standard, selective/delayed, and pulsed DC RCDs—targeting installers working to domestic UK standards. The LRCD220, the most feature-rich variant, supports 110 V loop testing, two-wire fast testing, phase-to-phase and phase-to-earth measurement, and offers automatic RCD testing and test result recall for advanced troubleshooting and certification. With plug versions for BS1363 (UK), CEE7/7 (Europe), and AS/NZS 3112 (Australia/New Zealand), and accessories tailored for regional requirements, the LRCD200 series can be seamlessly integrated into any professional toolkit worldwide.

Seamless Data Acquisition, Interpretation, and Recall

Ease of operation is a recurring theme throughout the LRCD200 range. Automatic test selection, bright easy-to-read displays, and simple rotary dial controls eliminate user error and reduce learning time. The advanced models (LRCD220) introduce automatic RCD testing where sequences are executed automatically—operators can stand by the device and easily recall results from memory, which is particularly useful during complex certification or repetitive testing sequences. Accurate loop measurement (from 0.01 Ω to 2 kΩ), auto-ranging, supply voltage display, and frequency measurement capabilities enhance utility and productivity on-site. Prospective fault current (PFC) calculation and display streamline fault analysis, essential for preventive maintenance and safety validation.

The Global Leader: tpt24 for Guaranteed Authenticity

When it comes to purchasing the Megger LRCD200 series, choosing the right distributor is crucial to ensuring authenticity, warranty coverage, and overall satisfaction. tpt24 stands out as the world’s best online store for this high-performance product series, delivering genuine and brand-new instruments direct from the manufacturer to any country. tpt24 guarantees not only the originality and quality of every device but also offers global after-sales support, professional advice, and fast, secure shipping. Customers can trust tpt24 for receiving official calibration certificates, accessories, and documentation, making it the preferred choice for professionals seeking peace of mind and reliable service on a global scale.

Technical Details and Specifications for Professionals

The technical specification of the Megger LRCD200 series is tailored for rigorous field applications and international compliance. All units measure voltage from 0 to 500 V (±2% ±2 digits) and frequencies between 25 Hz and 450 Hz. Loop tests (EN 61557-3 compliant) use low current, non-tripping technology and display values across a wide range with auto-ranging. RCD tests accommodate devices from 10 mA up to 1000 mA (on selected models), perform ramp and multiple I tests, and offer both touch voltage measurement and selection (25 V/50 V). Operating temperature spans -5°C to +40°C with humidity tolerance up to 93% at 40°C. The units are powered by eight AA batteries, weigh 980 grams, and measure 203 x 148 x 78 mm. All variants meet IP54 environmental protection and international EMC standards.

Specifications

Feature Specification
Voltage Measurement Range 0 – 500 V (±2% ±2 digits)
Frequency Measurement Range 25 Hz – 450 Hz (±0.1 Hz to ±1 Hz)
Loop Test Range 0.01 Ω – 2.00 kΩ (Auto-ranging)
Loop Test Current Nominal 15 mA
Loop Test Accuracy 0.01–9.99 Ω: ±5% ±0.03 Ω<br>10–99.9 Ω: ±5% ±0.5 Ω<br>100–999 Ω: ±5% ±5 Ω<br>1.00–2.00 kΩ: ±5% ±30 Ω
RCD Test Ranges 10, 30, 100, 300, 500 mA (LRCD200/210)<br>10, 30, 100, 300, 500, 1000 mA (LRCD220)
RCD Test Functions 1/2I, I, 5I (depending model), Ramp test, Type AC, A, S, 0/180°
Display Backlit LCD (LRCD220), Digital
Test Sequence Automatic RCD sequence and recall (LRCD220)
Touch Voltage Display 0–50 V, Selectable 25/50 V
Prospective Fault Current (PFC) Calculated and displayed
Plug Types BS1363, CEE7/7, AS/NZS 3112 (model dependent)
Case and Protection Rubber-armored, Built-in cover, IP54
Power Supply 8 x AA cells (alkaline/rechargeable NiMH/NiCd)
Battery Life 2000 tests (approximate)
Weight and Size 980 g, 203 x 148 x 78 mm
Operating Environment -5°C to +40°C, ≤93% RH at 40°C
Safety and Standards IEC61010-1 Cat III 300 V, EN61557 (Parts 1, 3, 6), IEC61326-1 EMC
Warranty 3 years

Data Sheet

Download Data Sheet Of Megger LRCD200 series Combined loop and RCD testers

Reviews

There are no reviews yet.

Be the first to review “Megger LRCD200 series Combined loop and RCD testers”

Your email address will not be published. Required fields are marked *