Megger LTC135 Load tap changer testing power supply

SKU: 4695814-1-752
In Stock

  • Maximum DC output: 5 Amperes
  • Supports three-phase DC testing
  • High-precision shunt output
  • Operating temperature: -20°C to +65°C

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Purpose-Built Power For Tap Changer Testing

The Megger LTC135 Load Tap Changer Testing Power Supply stands out as a highly specialized accessory, designed explicitly for advanced maintenance and diagnostic testing of load tap changers (LTC) in power transformers. Transformers are crucial within electrical distribution networks, providing voltage regulation and adaptation according to operational requirements. The only moving part connected to transformer windings is the load tap changer. Any malfunction or degradation in the LTC can severely compromise system reliability. The high costs and operational disruptions associated with decommissioning transformers solely for LTC inspection stress the importance of adopting sophisticated, diagnostic tools. The LTC135 offers a non-intrusive testing alternative, efficiently delivering test currents required for multiple essential measurements on LTCs, significantly extending the longevity of transformer assets.

Seamless Integration With Megger Test Equipment

Compatibility is a notable hallmark of the LTC135, ensuring seamless operation with various Megger circuit breaker analyzers. Specifically, the LTC135 has been engineered to work hand-in-hand with the EGIL, TM1600/MA61, TM1700 series, and TM1800 test instruments. This flexibility permits streamlined test procedures across different transformer types and substations. When paired with any of these circuit breaker analyzers, the LTC135 does far more than just provide current—it becomes an essential part of a comprehensive test system. This setup not only simplifies workflow for maintenance crews in the field but also enhances the quality and scope of diagnostics, enhancing transformer reliability across diverse installations and environments.

Unmatched Versatility For Condition Assessment Applications

The Megger LTC135’s core value emanates from its broad application spectrum in transformer maintenance and diagnostics. Its primary use is in performing dynamic resistance measurements (DRM) on load tap changers, a task essential for evaluating the health of arcing contacts, transition resistors, and the overall switching mechanism. With DRM, users can detect degradation such as coking of contacts, increased resistance due to wear, improper tap operation timings, and faults within transition components. These insights are unattainable through traditional static winding resistance measurements alone. In addition, the LTC135 is fully capable of executing winding resistance measurements, crucial for identifying open circuits, shorted windings, or general contact condition. Its ability to support switch sequence timing and transition/resistor measurement elevates it as a central diagnostic hub for transformer health assessments.

Enhanced Measurement Accuracy And Safety Features

Providing a constant, highly controlled DC current test signal is foundational to the LTC135’s performance. This precise current delivery ensures reliable resistance measurements and reproducible test results across applications. The unit outputs up to 5 A DC, with output ranges suitable for both single-phase and three-phase testing arrangements. Essential safety features are embedded, such as provisions for rapid transformer winding discharge upon test completion, which mitigates risks to both equipment and test personnel. The power supply’s robust design assures stable performance in high-voltage substations and diverse industrial environments, handling operational temperatures from -20°C to +65°C and humidity up to 95%, non-condensing.

Streamlining Transformer Maintenance And Diagnostic Routines

Routine and condition-based assessments of transformer LTCs are integral to utility reliability strategies. The LTC135’s measurement and testing capabilities streamline maintenance cycles by enabling early detection of faults and performance deviations. Dynamic resistance measurement, in particular, provides invaluable real-time profiles of LTC operation, capturing switching events and resistance fluctuations as the tap changer moves from one tap to another. This real-time monitoring, when visualized as resistance or voltage traces, highlights anomalies and informs maintenance schedules. In effect, the LTC135 not only reduces the potential for catastrophic failures but also minimizes unplanned outages and maintenance costs—a critical advantage for power utilities and industrial users alike.

Application-Specific Benefits Across Global Utilities

In practical settings, the primary beneficiaries of the LTC135 are high-voltage substations and industrial facilities where transformer performance is paramount. Applications include dynamic resistance and timing tests that detect incipient issues before they escalate into critical failures. The unit is effective for routine testing during planned turnarounds or on-site troubleshooting when transformer behavior is suspect. Its reliability and accuracy are proven across a range of supported Megger analyzers, accommodating various test strategies such as single- or three-phase dynamic testing, continuity verification, and timing analysis. By ensuring condition-based maintenance, the LTC135 directly supports higher transformer availability, longer equipment service life, and optimized operational expenditure—outcomes vitally important to all users managing critical power infrastructure.

Global Delivery And Quality Guarantee At tpt24

Purchasing the Megger LTC135 from tpt24, the globe’s top online store for specialist test and measurement equipment, ensures buyers receive an authentic product guaranteed for quality and performance. tpt24 is recognized worldwide for its commitment to customer satisfaction, delivering the LTC135 with a warranty of authenticity and operational excellence, regardless of the customer’s country or region. Whether you are a public utility in Europe, an industrial facility manager in America, or a maintenance contractor in Asia or Africa, tpt24’s global supply chain ensures prompt, reliable delivery, and professional support. Choose tpt24 to secure your investment in transformer reliability, backed by a trusted after-sales network and a worldwide reputation for excellence.

Comprehensive Technical Credentials And Practical Design

A closer examination of the LTC135’s technical credentials reveals a sophisticated, user-focused design. The unit is compact and robust, weighing only 6.5 kg (instrument alone) and supplied with a rugged carrying bag and cables, ensuring portability for field engineers. The maximum input is 300 W, supporting an operating voltage between 100 and 250 V AC (50/60 Hz), adaptable to diverse site conditions. Output currents are selectable, with three outputs each for 0.1 A, 1 A, and a single 5 A channel, all at an open circuit voltage of 48 V. High precision shunt outputs (with only 0.1% inaccuracy) reinforce the reliability of measurement results. The device is EMC and LVD compliant, safe for use in demanding environments, and includes full documentation to support straightforward, efficient use.

Specifications

Attribute Specification
Product Status Discontinued
Max Output Current (DC) 5 A
Output Currents 3 x 0.1 A, 3 x 1 A, 1 x 5 A
Open Circuit Voltage 48 V
Output Impedance 480 Ω (0.1 A), 48 Ω (1 A), 9.6 Ω (5 A)
Shunt Output 1 V/0.1 A, 1 V/1 A, 1 V/5 A
Shunt Inaccuracy 0.1% for all ranges
Supported Measurement Types Winding resistance, DRM, timing
Power Consumption 300 W max
Mains Voltage 100-250 V AC, 50/60 Hz
Single/Three-Phase 3-phase
Dimensions (mm) 360 x 195 x 300
Weight (instrument only) 6.5 kg (14.3 lbs)
Weight (with accessories) 10.9 kg (24 lbs)
Operating Temperature -20°C to +65°C (-4°F to +149°F)
Storage Temperature -40°C to +85°C (-40°F to +185°F)
Relative Humidity 5%-95%, non-condensing
Application Field High-voltage substations, industry
Instruments Supported EGIL, TM1600/MA61, TM1700, TM1800
Accessories Test leads (x3), carrying bag
EMC Compliance Yes (2004/108/EC)
LVD Compliance Yes (2006/95/EC)

Data Sheet

Download Data Sheet Of Megger LTC135 Load tap changer testing power supply