Megger MLLA low level adaptor
- Rogowski output ranges: 2/10/40 V
- High accuracy, 0.001 V resolution
- Compatible with SMRT/FREJA series
- Robust IP20-rated lightweight enclosure
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Innovative Megger MLLA Low Level Adaptor
The Megger MLLA Low Level Adaptor represents a key advancement for test engineers, relay technicians, and protection specialists seeking reliable methods for simulating low-level voltage outputs. Particularly, the MLLA adapts to the evolving world of non-conventional instrument transformers (NCITs), such as Rogowski coils and capacitive voltage transformers (CVTs) used in modern substations. By converting the current output channels of selected Megger SMRT and FREJA test sets to precise millivolt voltage sources, the MLLA enhances the capability of test equipment, making it ideal for the low-voltage interfaces increasingly required by new generations of protective relays. The MLLA is engineered for high accuracy, resolution, and robust performance, ensuring it remains a fundamental accessory for anyone working with secondary injection testing and relay calibration in complex electrical grids.
Dedicated Design for Modern Test Challenges
Technological progress in power grid protection requires test equipment to handle ever-lower signal levels with accuracy and fidelity. The Megger MLLA Low Level Adaptor was built specifically to interface with the latest SMRT series and FREJA 500 series test sets, starting from hardware revision 3.51 and firmware 6.150 upwards. At its core, the MLLA is designed to filter the low-level outputs from these units, suppressing unwanted noise and enhancing signal clarity during relay testing. Its Rogowski mode transforms the current source into a millivolt output, thereby enabling users to simulate the specific type of low-level voltage generated by Rogowski coils. This adaptation is crucial for robust, error-free relay testing, where even minor inaccuracies could result in improper relay operation in live substation environments.
Wide Application and Technical Flexibility Highlighted
The Megger MLLA’s applications are both wide and specialized. One of its primary uses is to provide a stable interface for relay testing in systems using low-level voltage signals, such as those generated by modern Rogowski coils and certain CVTs. The MLLA supports three selectable output voltage ranges—2 V, 10 V, and 40 V—accommodating the various requirements of contemporary relay designs. In low voltage mode, it offers an output from 0 to 2 V with extraordinary resolution and accuracy, down to 0.001 V increments. This makes it ideal for testing relays like the ABB REF615 and Siemens 7SJ81, which rely on non-conventional transformers and expect reliable, noise-free low-level analog signals for accurate protection operation. Furthermore, the MLLA can be configured and managed through the intuitive Relay Test Management Software (RTMS), which simplifies the adjustment of amplitude ratios and phase correction factors to match relay requirements with precision.
Essential Component for Reliable Relay Testing
As the power utility sector shifts towards digital substations and advanced relay designs, having highly adaptable test accessories like the MLLA is essential for ensuring safe and accurate operation. The Megger MLLA Low Level Adaptor acts as the critical interface between Megger SMRT or FREJA test sets and the increasingly prevalent relays utilizing low-level signal inputs. The low-level outputs produced by the adaptor are filtered and isolated to avoid interference and maintain measurement integrity. Features such as high fidelity signal conversion, multiple output ranges, and easy terminal connections make the MLLA invaluable for testing a wide range of protective relay brands and models, from ABB and Siemens to Schneider. Its role in the testing ecosystem enables rapid, accurate commissioning and maintenance of protection systems, minimizing the risk of outages and maloperations.
Specific Usage Scenarios Across Global Power Networks
The Megger MLLA finds precise application in a diverse set of field and laboratory settings. In substations, it is frequently used for routine maintenance, calibration, and acceptance testing of equipment relying on Rogowski coil technology—a technology known for its accuracy in transient current measurement and ease of retrofitting. The MLLA has proven its effectiveness for end-to-end tests of numeric relays such as the ABB REF615, REF542plus, REX521, REC523, and REF603 series, as well as Siemens 7SJ81 and Schneider Easergy P5. With the MLLA, utility technicians can accurately simulate and deliver the specific voltage scale of the Rogowski coil or voltage divider outputs required by the relay under test. This capability is supported by adapter cable kits—color-coded and engineered for compatibility—with connection options available for a wide array of relay models. In essence, the MLLA streamlines the otherwise complex process of matching test set output with relay input sensitivity and formatting.
Seamless Integration with Management and Control Software
A noteworthy advantage of the Megger MLLA lies in its seamless integration with Megger’s RTMS (Relay Test Management Software) and FREJA Local/Remote software solutions. RTMS provides comprehensive control over the configuration of low-level channels, range selection, and real-time adjustment of output amplitude and phase correction factors. Engineers can set secondary current-to-millivolt relationships, calibrate measurement points, and tailor outputs specifically for each test job. This software-based flexibility enables the MLLA to keep pace with emerging standards and relay technologies. Furthermore, with firmware and hardware compatibility criteria explicitly stated, users are empowered to upgrade or field-retrofit their SMRT or FREJA units with confidence—supported by documentation and software updates available from Megger.
Global Trust and Guaranteed Authenticity Through tpt24
When it comes to purchasing specialized testing accessories such as the Megger MLLA Low Level Adaptor, reliability in sourcing is absolutely vital. The tpt24 online store stands out as the premier, globally trusted source for the MLLA and other high-precision Megger products. Customers worldwide are guaranteed authentic, certified devices, as tpt24’s stringent quality assurance and global fulfillment ensure the product arrives in pristine condition, fully backed by Megger’s warranties. Regardless of your location, tpt24 simplifies the procurement process with expert customer support, direct shipment, and the latest hardware and cable accessory options. This makes tpt24 the leading choice for utility engineers, relay testers, and maintenance professionals who demand only the best and most reliable testing solutions for their vital protective equipment.
Technical Characteristics Central to Professional Performance
The Megger MLLA is engineered for unmatched accuracy, flexibility, and long life in the field. Its rugged, lightweight UL94 V0 enclosure protects the internal electronics from harsh electrical and environmental conditions. Key environmental ratings—including an IP20 enclosure, extensive shock and vibration resistance, and wide operational temperature and humidity tolerance—make it ideal for substations and industrial settings worldwide. Output accuracy is exceptionally high, with resolution increments down to 0.001 V, and all specifications are supported by international safety and EMC certifications. With industry-proven firmware, robust hardware design, and sophisticated filtering, the MLLA is a benchmark for reliable performance and durability in mission-critical relay testing.
Specifications
| Specification | Details |
|---|---|
| Product Name | Megger MLLA Low Level Adaptor |
| Output Voltage Ranges | 2 V, 10 V, 40 V (Rogowski Mode) |
| Low Voltage Output Range | 0–2 V (high resolution and accuracy) |
| Voltage Output Resolution | 0.001 V (across all ranges) |
| Voltage Accuracy (0-1 V) | 0.5 mV typical, 1 mV guaranteed |
| Voltage Accuracy (1-2 V) | 0.5 mV typical, 2 mV guaranteed |
| High Range Accuracy | ±0.05% reading + 0.02% range typical,<br>±0.15% reading + 0.05% range guaranteed |
| Current Output Range | 0–50 mA (Rogowski simulation) |
| Measurements Type | AC RMS |
| Compatible Devices | Megger SMRT (HW ≥3.51, FW ≥6.150),<br>FREJA 500 series (with low-level option) |
| Software | Relay Test Management Software (RTMS), FREJA Local/Remote |
| Environmental Temperature | Operating: 0–50°C; Storage: -25–70°C |
| Humidity | 5 – 90% RH (non-condensing) |
| Altitude | Operating: Up to 3000 m |
| Enclosure | Rugged lightweight plastic, UL94 V0, IP20 |
| Dimensions (L x W x H) | 14.80 cm x 3.47 cm x 6.60 cm (max) |
| Weight | 0.45 kg (1 lb.) |
| Safety/EMC Certifications | EN 61010-1, UL 61010-1, CSA C22.2 #61010-1, EN 61326-2-1, EN 61000-3-2/3 |
| Accessory Kit Options | Custom cable kits for ABB, Siemens, Schneider relays |
| Applicable Use | High-voltage substations, industrial environments, relay testing |
| Firmware/Hardware Requirement | SMRT/FREJA HW ≥3.51, Firmware ≥6.150, VIGENS HW ≥3.5.1 |
| Country of Origin | United States |
| Guarantee/Support | Available worldwide via tpt24 |