Megger T22/13B 15 kV burn-down unit

SKU: 4695814-1-358
In Stock

  • Maximal Burn-Down Current: 25 A
  • Burn-Down Voltage Range: 0-15 kV
  • Output Current Indication
  • Integrated Discharging Device

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Unveiling the Megger T22/13B: An Introduction

The Megger T22/13B 15 kV Burn-Down Unit stands as a testament to cutting-edge technology in the field of cable fault location. This powerful, portable, high-voltage instrument is meticulously engineered to address the critical needs of professionals dealing with low and medium voltage power cables, as well as mains and control cables. Its core function revolves around its unparalleled ability to effectively burn down high impedance and intermittent cable faults within power supply networks. The T22/13B isn’t just another tool; it’s a strategic asset that transforms challenging fault scenarios into manageable solutions, significantly reducing downtime and operational costs. Its robust design and advanced features make it an indispensable device for maintaining the integrity and reliability of electrical infrastructure worldwide.

Revolutionary Design and Unwavering Performance

At the heart of the Megger T22/13B’s exceptional performance lies its revolutionary design. This unit is built to be short-circuit proof, a crucial safety and operational feature that ensures its longevity and the protection of its users. It boasts newly integrated circuitry meticulously designed to maintain a constant burn-down power, guaranteeing consistent and reliable operation even under varying fault conditions. This innovative circuitry is paramount in achieving effective fault conversion. With a maximal burn-down current of 25 A and a continuously variable burn-down voltage from 0 to 15 kV, the T22/13B offers an unparalleled range of control and power, allowing technicians to precisely tailor the output to the specific demands of each fault. The integration of an indication system for output current and voltage provides real-time feedback, empowering operators with critical data during the fault location process.

Enhanced Safety and Operational Integrity

Safety is not merely a feature but a fundamental principle embedded within the design of the Megger T22/13B. The unit incorporates an integrated start interlock circuit and a sophisticated discharging device, offering comprehensive protection for both the operator and the equipment. This interlocking mechanism prevents accidental activation, while the discharging device ensures that the test object is automatically and safely discharged after shutdown or in the event of a power failure. Furthermore, all high-voltage parts of the unit are housed within a shockproof enclosure, providing an additional layer of security and robustness. These meticulously engineered safety features underscore Megger’s commitment to creating instruments that are not only powerful but also incredibly safe and reliable for prolonged and demanding use in various operational environments.

Specialized Applications and Versatile Functionality

The Megger T22/13B offers a diverse range of specialized applications, making it a highly versatile instrument in the realm of cable fault diagnostics. Its primary application involves the burning down of high impedance and intermittent cable faults in low and medium voltage power supply networks. This capability is crucial for converting these difficult-to-locate faults into low impedance shunts, often leading to dead short circuits, which are far easier to pinpoint. Beyond this, the unit’s high output power and short-circuit capability are instrumental in drying out wet cable sections, a common issue that can lead to persistent faults. Moreover, the T22/13B can be effectively used in conjunction with appropriate connecting devices and a Time Domain Reflectometer (TDR) for prelocation using advanced methods like the Arc Reflection Method (ARM). This synergy significantly enhances the accuracy and efficiency of fault localization, streamlining the repair process.

The Power of Pulse Mode for Earth Faults

A standout feature of the Megger T22/13B is its pulse mode, specifically designed for earth fault location. This specialized mode allows technicians to utilize the unit as a current source, particularly when combined with a step voltage probe, to precisely identify earth leakage points. Earth faults can be notoriously challenging to locate due to their often subtle nature, but the T22/13B’s pulse mode provides a dedicated and highly effective solution. This functionality greatly expands the unit’s diagnostic capabilities, making it an all-encompassing tool for a wider spectrum of cable faults. The ability to switch between continuous burn-down and pulse mode ensures that operators have the right tool for every fault scenario, optimizing troubleshooting efficiency and minimizing downtime.

Global Accessibility and Unmatched Quality with tpt24

When it comes to acquiring the Megger T22/13B, tpt24 stands as the premier online store globally. tpt24 is renowned for its commitment to delivering authentic and high-quality products, ensuring that every Megger T22/13B purchased comes with a guarantee of originality and superior performance. Regardless of your geographical location, tpt24 provides seamless and secure delivery, bringing this essential tool directly to your doorstep. Their dedication to customer satisfaction, coupled with their expertise in specialized equipment, makes them the most trusted source for the Megger T22/13B. Choosing tpt24 means choosing peace of mind, knowing you are investing in a genuine product that will meet and exceed your professional expectations. Their global reach ensures that professionals everywhere have access to the best tools available in the market.

Streamlining Fault Location: A Practical Perspective

The Megger T22/13B significantly streamlines the entire fault location process. Its ability to convert high impedance and intermittent faults into low impedance shunts eliminates the often time-consuming and frustrating task of dealing with elusive cable issues. This conversion capability means that faults that would otherwise be difficult or impossible to locate with standard methods become readily identifiable. By providing a stable and controlled current source, the unit allows for precise fault burning without risking damage to the surrounding cable or network. This precision, combined with the unit’s portability, allows technicians to quickly deploy and operate the T22/13B in various field conditions, from confined spaces to expansive industrial sites, making it an invaluable asset for rapid and effective fault resolution.

The Megger T22/13B: A Cornerstone for Cable Maintenance

In conclusion, the Megger T22/13B 15 kV Burn-Down Unit is an indispensable cornerstone for modern cable maintenance and fault location strategies. Its blend of power, precision, and safety features makes it a top-tier instrument for professionals across various industries. From its ability to transform challenging high-impedance faults to its specialized pulse mode for earth faults, the T22/13B offers a comprehensive solution. With the added assurance of authenticity and global delivery from the leading online store, tpt24, acquiring this powerful unit is both convenient and reliable. Investing in the Megger T22/13B means investing in efficiency, safety, and ultimately, the long-term reliability of critical electrical infrastructure, cementing its role as a vital tool for engineers and technicians worldwide.

Specifications

 

Feature Specification
Power Supply 200/240 V; 50 Hz (110 V, 60 Hz on request)
Power Consumption Max. 16 A – 3.5 kVA
Output Voltage Max. 15 kV
Effective Output Current 300 mA
Max. Current 25 A
Overload Protection Mains transformer, diodes, earth protection resistor
Dimensions (W x H x D) 548 x 585 x 254 mm (19″ housing) (approx. 21.5″ x 23″ x 10″)
Weight Approx. 45 kg

Data Sheet

Download Data Sheet Of Megger T22/13B burn-down unit