Emerson Micro Motion T050T Straight Tube Coriolis Meter
- Pressure Rating 100 barg Max
- Mass Accuracy ± 0.15 Percent
- Density Accuracy ± 0.002 g/cm³
- Titanium Grade 9 Construction
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Micro Motion T050T Straight Tube Coriolis Meter
Titanium Precision for Hygienic Process Measurement Reliability
The Rosemount T050T Micro Motion Straight Tube Coriolis Meter represents the pinnacle of hygienic metering technology, combining precision performance with uncompromising material integrity. Constructed from Titanium Grade 9, this sensor delivers long‑term corrosion resistance and excellent material strength while maintaining exceptional sensitivity to flow and density variations. Its 32 Ra surface finish provides a sanitary, drainable interior ideal for applications where contamination is unacceptable. Designed with a single straight‑tube configuration, the T050T ensures plug‑resistant fluid dynamics and consistent accuracy across liquids and gases alike. Offering mass flow accuracy of ±0.15% for liquids and density accuracy of ±0.002 g/cm³, the meter achieves reliable measurements under demanding pressure conditions up to 100 barg (1,450 psig). This combination of strength, precision, and hygiene makes the T050T one of the most technically advanced Coriolis instruments available for modern manufacturing, ensuring stable operation in every production cycle.
Global Certifications Establishing Universal Process Confidence
Each Rosemount T050T meter undergoes extensive factory testing and calibration to meet internationally recognized certifications, including UL, CSA, ATEX, ASME, 3‑A, USDA, and EHEDG. Emerson engineers have tailored the meter to fulfill requirements for both hygienic and hazardous operating zones, verified through IECEx, NAMUR, and IP 66/67 ratings. These credentials signify global acceptance—whether a dairy line in Germany, a pharmaceutical cleanroom in Singapore, or a biotech plant in Brazil. The hygienic certifications, particularly 3‑A and EHEDG, guarantee that wetted surfaces conform to strict sanitary norms, preventing microbial retention during operation and cleaning. Because of its titanium construction, the meter resists chemical attack from sterilizing agents used in CIP (Clean‑in‑Place) and SIP (Steam‑in‑Place) systems, maintaining measurement stability through repeated sterilization cycles. These approvals affirm that every T050T achieves regulatory compatibility for food, beverage, and life‑science industries worldwide.
Designed for Direct In‑Line Measurement Versatility
The T050T provides simultaneous measurement of mass flow, volume flow, density, concentration, and temperature directly in‑line from one compact device. This eliminates the need for separate transmitters or auxiliary sensors, simplifying instrumentation architecture across production lines. Thanks to its broad transmitter compatibility—including Emerson’s 5700 Series 9‑wire and digital communication modules—the meter interfaces easily with HART, Profibus‑PA, and FOUNDATION Fieldbus systems. Engineers appreciate its reliable measurement responsiveness, even through rapid process transients such as filling, blending, or dosing. In manufacturing environments where precision means profitability, the T050T reduces performance drift and enhances batch repeatability by ensuring constant mass balance verification. The unit’s dynamic range makes it equally effective for monitoring low‑density process gases or viscous liquids, while still maintaining linearity under pulsating flow conditions. For plants seeking a single measurement solution compatible with diverse fluids, this titanium model delivers comprehensive in‑line process visibility.
Specialized Industry Applications Defining Its Global Utility
The T050T is indispensable in hygienic sectors where product safety and measurement stability are critical. In food and beverage production, it measures syrup flow, dairy homogenization, and carbonation gas blending with repeatability of ±0.05%. In pharmaceutical processing, it precisely monitors excipient dosing and buffer preparation, crucial for IV solution consistency. Biotechnology fermenters use the meter to gauge nutrient feed and monitor density fluctuations within microbial culture reactors. The cosmetic and personal‑care industry applies the T050T for high‑purity lotion ingredients that require sterile transfer. Its high‑pressure design supports aseptic packaging systems, enabling safe metering of sterilized fluids without risk of contamination. The hygienic titanium tube prevents adsorption of complex organics—ideal for enzyme solutions and vaccine production lines. Across these diverse industries, the T050T guarantees consistent, contamination‑free measurements, maximizing operational uptime while surpassing regulatory purity expectations demanded by global health and safety standards.
Superior Titanium Design Simplifying Cleaning and Maintenance
Maintenance efficiency is central to the T050T’s operational value. Its smooth 32 Ra surface finish and drainable straight‑tube geometry remove virtually all areas where residues could accumulate, making it ideal for CIP and SIP routines. Cleaning fluids and steam flow evenly throughout the tube without turbulence dead zones, ensuring maximum sanitation and fast turnaround between production shifts. Titanium’s inert oxide film resists aggressive detergents and acidic sanitizers commonly used in beverage or pharmaceutical sterilization processes. The absence of parallel flow paths means less frictional resistance, reducing pressure drops and mechanical strain on pumps. Operators benefit from quicker process restart times after cleaning, straight‑forward validation procedures, and reduced downtime. The robust mechanical structure requires no cumbersome straight‑run piping or flow conditioners—saving installation space and simplifying system layout on compact production skids or filling modules. Altogether, this design philosophy promotes reliability, cleanliness, and cost‑effective lifecycle management.
Reliability and Safety Across Hazardous Processing Environments
Emerson built the T050T not only for hygienic accuracy but also for reliability under potentially explosive or corrosive conditions. ATEX and CSA Class I Div 1 ratings enable deployment in zones exposed to flammable vapors, where electrical integrity and surface temperature control are essential. Titanium’s non‑sparking nature adds further passive safety. In chemical clean‑rooms or solvent lines, titanium mitigates reaction risks while delivering consistent readings without degradation. Combined environmental protections under IP66/67 ensure total sealing against dust intrusion and high‑pressure wash‑down sprays. Even where sterilization cycles induce temperature fluctuations, the meter maintains ±1 °C precision across readings, enabling confidence in thermal compensation routines. Emerson’s precision engineering ensures each unit maintains calibration stability through vibration, humidity, and dynamic loading over decades. This reliability establishes the T050T as the go‑to Coriolis meter for facilities that require seamless performance where hygiene and safety coexist—an embodiment of durability through intelligent design.