SKC Split2 Particulate Monitor
- Passive/active dust monitor
- Instantaneous display TWA/STEL
- Over 8-hour battery life
- Automatic data logging
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Versatile Dust Monitoring Capabilities
The Split2 is engineered for versatility, specifically designed for both personal or area monitoring of either inhalable or respirable dust. This adaptability means it can cater to various assessment strategies, whether you’re evaluating individual worker exposure or assessing ambient air quality within a larger space. Its core strength lies in its ability to function as a passive dust monitor, providing immediate, instantaneous readings without the need for an external pump. This allows for quick spot-checks and rapid identification of potential dust sources, making it a highly responsive tool for dynamic environments where conditions can change rapidly.
Passive and Active Dual Functionality
A key innovation of the Split2 is its dual functionality. While it excels as a passive monitor, it can seamlessly become an active monitor/sampler by combining it with a 2 L/min sample pump. When paired with an IOM sampling head or GS-3 Cyclone, it enables concurrent real-time dust monitoring and gravimetric dust sampling. This integration removes the need for two separate devices, streamlining fieldwork and ensuring that the real-time data correlates directly with the gravimetric sample. This comprehensive approach provides both immediate insights into dust levels and a verifiable sample for laboratory analysis, crucial for accurate exposure assessments and regulatory compliance.
Instantaneous Display for Quick Insights
The Split2 offers instantaneous display of TWA (Time-Weighted Average), STEL (Short-Term Exposure Limit), Minimum, and Maximum concentrations in mg/m3. This real-time feedback is invaluable for immediate assessment of airborne particulate levels, allowing users to quickly identify peak exposures and understand concentration fluctuations. The accurate measurements over a wide measuring range ensure reliability across various dust environments, from low background levels to high exposure scenarios. Furthermore, its backlit display for use in dim light conditions ensures clear visibility of data, regardless of the ambient lighting, enhancing its utility in diverse working environments.
Compact, Lightweight, and Extended Operation
Designed for user convenience, the Split2 is remarkably compact and lightweight. This makes it easy to wear for personal monitoring, minimizing discomfort for the user during extended work shifts. Despite its small size, it boasts an impressive battery life, operating for over 8 hours using a rechargeable NiMH battery. For even longer monitoring periods, it offers extended running time using an AC charger, ensuring continuous operation when power is available. This combination of portability, long battery life, and flexible power options makes the Split2 a highly practical and reliable instrument for prolonged fieldwork without frequent interruptions.
Audible Alarm and Automatic Data Logging
To enhance safety and data integrity, the Split2 is equipped with an audible alarm with an adjustable threshold. This feature provides immediate notification when dust concentrations exceed a pre-set limit, allowing for prompt intervention to mitigate exposure. Beyond real-time alerts, the instrument offers automatic data logging, continuously recording concentration changes over time. This automated process ensures that a complete historical record of exposure is maintained, which is vital for compliance, trend analysis, and post-incident investigations. The combination of active alarms and comprehensive data logging provides both immediate protection and valuable long-term insights into air quality.
Comprehensive Data Analysis with Software
The data collected by the Split2 can be seamlessly managed and analyzed using the easy-to-use DustComm Pro Software. This powerful software facilitates data downloading, trend analysis, and comprehensive reporting of concentration changes over time. Users can visualize exposure patterns, identify periods of high particulate levels, and generate detailed reports for regulatory compliance, risk assessment, or research purposes. This integrated software solution transforms raw data into actionable intelligence, empowering industrial hygienists and safety professionals to make informed decisions and implement effective control measures based on solid evidence.
Diverse Applications Across Industries
The Split2’s versatility and dual monitoring/sampling capabilities make it indispensable across a wide range of diverse applications. In occupational hygiene, it is used for personal exposure monitoring in industries like construction, manufacturing, mining, and agriculture, assessing worker exposure to various dust types. For environmental monitoring, it can be deployed for area assessments in public spaces, fenceline monitoring around industrial facilities, and investigations into fugitive dust emissions. Its specific compatibility with IOM samplers and GS-3 Cyclones makes it ideal for targeted inhalable or respirable dust assessments, crucial for understanding health risks associated with different particle sizes. Whether for compliance, risk management, or research, the Split2 provides reliable data for comprehensive air quality evaluations.
Acquire Your Split2 from tpt24
When you are ready to invest in the innovative capabilities and reliability of the SKC Split2, tpt24 stands as the premier online store globally. With an unwavering commitment to authenticity and quality, tpt24 guarantees that every SKC Split2 delivered is a genuine product, meeting the highest performance standards. Regardless of your geographical location, tpt24 provides worldwide delivery, offering unparalleled access to this essential piece of equipment. Their reputation for reliability and dedication to customer satisfaction makes them the most trusted source for professionals seeking top-tier dust monitoring and sampling technology. Choosing tpt24 for your Split2 purchase means investing in a product that will consistently meet your demands, backed by a retailer that prioritizes your needs and guarantees a smooth, secure acquisition process.
Specifications
| Flow Rate | 2 L/min using an external pump (not included) | |
| Accuracy | ±10% to NIOSH Method 0600 using SAE fine test dust | |
| Sensing Range | 0.01 to 200 mg/m3 | |
| Display Resolution | 0.01 mg/m3 | |
| Particle Size Range | 0.1 to 100 µm | |
| Measurement Precision | ±0.02 mg/m3 | |
| Calibration | NIOSH gravimetric using NIST-traceable SAE fine test dust | |
| Displayed Particle Concentration | Instantaneous, TWA, STEL, Minimum, Maximum | |
| Active Mode | Use with sample pump at 2 L/min | |
| Power | Rechargeable NIMH battery | |
| Operating Time | ≥8 hours | |
| Charging Time | 12 hour | |
| Digital Output | RS-232 | |
| Data Storage | 21,500 data points | |
| Sampling Rate | 1 second, 1 minute, 10 minutes | |
| Temperature | Operating: 0 to +50°C (32 to 122°F) Storage: -20 to +60°C (-4 to 140°F) |
|
| Dimensions | Unit: 18 x 8 x 4.5 cm (7 x 3 x 2 inches) Sensor: 4.4 x 3.8 cm (1.75 x 1.5 inches) |
|
| Weight | 780 g with batteries |