UNI-T UT575B double-clamp multi functional earth tester
- Earth Resistance: 0.00Ω to 300.00kΩ
- Current/Voltage: 600A AC / 100V AC
- Soil Resistivity: Up to 9000KΩm
- Data Storage: 2000 sets
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Introducing UNI-T UT575B Earth Tester
The UNI-T UT575B Double-Clamp Multifunctional Earth Tester is a high-end, professional-grade instrument engineered for comprehensive and precise on-site measurement of various grounding parameters. Designed to meet the rigorous demands of modern electrical systems, the UT575B integrates advanced digital processing technology, offering unparalleled accuracy and reliability. Its versatility is highlighted by multiple measurement methods, including the conventional 2/3/4-wire, the innovative selective method, and the highly efficient double-clamp method. A key feature is its large-diameter current clamp, capable of accommodating conductors up to 70mm, enabling accurate measurements in complex environments without needing to disconnect the ground system. Equipped with robust data storage, real-time clock, Bluetooth, and USB capabilities, the UT575B facilitates seamless data management, analysis, and reporting. This makes it an indispensable tool for engineers, technicians, and safety professionals across various industries, including power generation, telecommunications, petrochemical, construction, and railway systems, where reliable grounding is paramount for safety and operational efficiency.
Unmatched Versatility in Grounding Measurements
The UNI-T UT575B Double-Clamp Multifunctional Earth Tester stands out with its exceptional versatility, offering a suite of measurement methods to tackle any grounding scenario. It supports the conventional 2-wire, 3-wire, and 4-wire earth resistance testing, providing precise measurements across a wide range from 0.00Ω to an impressive 300.00kΩ. The 4-wire method, in particular, offers the highest accuracy by effectively nullifying the resistance of the test leads and auxiliary electrodes, making it ideal for critical installations and compliance testing.
Beyond these traditional methods, the UT575B introduces the Selective Method, allowing for earth resistance measurements of individual grounding electrodes in parallel or networked systems without disconnection. This eliminates the time-consuming and often hazardous process of isolating each electrode, making it perfect for live substations, urban grounding grids, and complex industrial facilities, with a range of 0.00Ω to 3000Ω. Furthermore, the innovative Double Clamp Method provides quick, non-intrusive earth resistance measurements ranging from 0.01Ω to 100Ω. This method is exceptionally useful in situations where auxiliary electrodes cannot be driven, such as paved areas or rocky terrains, and allows for rapid checks of grounding continuity and integrity without requiring system shutdown.
Comprehensive Electrical Parameter Analysis
Beyond just earth resistance, the UNI-T UT575B is a true multifunctional instrument, offering comprehensive analysis of critical electrical parameters essential for assessing the health and safety of grounding systems. It accurately measures AC Ground Voltage from 0.0V to 100.0V (auto range), allowing users to detect hazardous voltage potentials on grounding conductors, crucial for identifying potential touch and step voltage risks. This capability is vital for ensuring personnel safety in and around electrical installations.
Additionally, the UT575B provides precise measurements of AC Earth Current from 0.00mA to an impressive 600.0A (auto range). This allows for the assessment of leakage currents, stray currents, and current distribution within grounding networks, helping to diagnose potential issues like corrosion, overheating, or inadequate fault current paths. The large 70mm clamp jaw diameter facilitates easy measurement of large conductors. The ability to measure both voltage and current provides a holistic view of the grounding system’s performance under operational conditions, empowering professionals to make informed decisions regarding maintenance, upgrades, and troubleshooting.
Advanced Soil Resistivity for Optimal Design
The UNI-T UT575B is an invaluable tool for soil resistivity measurement, ranging from 0.00Ωm to 9000KΩm (with a resolution of 0.01Ωm). Soil resistivity is a fundamental parameter for the design and installation of effective and economical grounding systems. Understanding the varying resistivity of the soil at different depths and locations is crucial for determining the optimal configuration, size, and depth of grounding electrodes required to achieve desired earth resistance values. The UT575B enables the accurate application of the Wenner or Schlumberger methods for soil resistivity profiling, allowing engineers to identify layers of high or low resistivity.
This capability is essential for various applications:
- Designing new grounding systems: Ensures cost-effective and compliant grounding installations for new buildings, power plants, and communication towers.
- Corrosion prevention: Identifies areas where soil conditions might accelerate corrosion of buried metallic structures.
- Fault current dissipation: Optimizes grounding grids for safe and rapid dissipation of fault currents, minimizing risk to personnel and equipment.
- Lightning protection: Aids in designing effective lightning protection systems by providing data on how rapidly lightning current will dissipate into the earth.
By providing precise soil resistivity data, the UT575B empowers designers to create efficient, safe, and long-lasting grounding solutions that meet specific performance criteria and regulatory standards.
Robust Anti-Interference for Accuracy
In today’s electrically noisy environments, accurate earth testing can be significantly challenged by interference. The UNI-T UT575B is specifically engineered with strong anti-interference capabilities to ensure reliable measurements even in the presence of substantial electrical noise. It features multiple test frequencies (128Hz/111Hz/105Hz/94Hz) with Automatic Frequency Control (AFC Auto), allowing the instrument to automatically select the most suitable test frequency that minimizes the impact of external noise. This intelligent frequency selection ensures that the measured values are true reflections of the earth resistance and not contaminated by stray currents, induction from nearby power lines, or harmonics.
This robust anti-interference performance is particularly critical in industrial zones, urban areas, and substations where power lines, machinery, and communication equipment generate significant electromagnetic interference. Without such capabilities, measurements can be erroneous, leading to misdiagnosis of grounding issues or, worse, a false sense of security regarding grounding system integrity. The UT575B’s ability to operate effectively in these challenging conditions provides engineers with high confidence in the accuracy of their readings, enabling precise fault detection, effective maintenance, and reliable compliance verification.
TPT24: Global Leader for UT575B
For professionals seeking the genuine UNI-T UT575B Double-Clamp Multifunctional Earth Tester, TPT24 is unequivocally the premier global online retailer. TPT24 is recognized worldwide for its unwavering commitment to providing products with an absolute guarantee of authenticity and unparalleled quality. Every UT575B purchased from TPT24 is certified to be a genuine UNI-T product, manufactured to the highest industry standards, ensuring peak performance and durability. This commitment to genuine products protects your investment and ensures you receive a reliable tool critical for your professional work.
Beyond authenticity, TPT24 distinguishes itself with its efficient and reliable worldwide delivery service. No matter where your operations are located – from bustling metropolitan centers to remote industrial sites across North America, Europe, Asia, Africa, or Oceania – TPT24 ensures that your UT575B reaches you promptly and securely. Their robust logistics network and dedicated customer support team streamline the purchasing process, offering peace of mind and convenience that is unmatched. Choosing TPT24 for your UNI-T UT575B means opting for assured quality, exceptional service, and global accessibility, solidifying their reputation as the most trusted online source for advanced testing instruments.
Smart Features for Enhanced Efficiency
The UNI-T UT575B is designed with a suite of smart features that significantly enhance operational efficiency and data management for professionals in the field. It boasts a substantial data storage capacity of 2000 sets, allowing technicians to meticulously record and organize a vast amount of measurement data directly on the device. This eliminates the need for manual transcription during testing, reducing errors and saving valuable time. Each stored record can be easily retrieved and reviewed on the large, clear LCD display with backlight, which ensures excellent visibility even in poorly lit environments.
For advanced data analysis and reporting, the UT575B includes PC software connectivity via USB B. This enables seamless transfer of stored data to a computer, where the specialized software can be used to generate comprehensive reports, visualize trends, and perform in-depth analysis of grounding system performance. The inclusion of Bluetooth connectivity further enhances convenience, allowing for wireless data transfer to compatible devices. Additionally, an audible alarm function provides instant feedback during testing, alerting the user to abnormal readings or conditions. Features like auto power-off and low battery indication optimize battery life and prevent unexpected interruptions, making the UT575B a highly intelligent and user-friendly instrument for modern professionals.
Specifications
| Models | UT575B |
| Earth resistance (2/3/4 wire testing) | 300.00kΩ |
| Earth resistance (selective method) | 3000Ω |
| Earth resistance (double clamp method) | 100Ω |
| Soil resistivity | 9000kΩ |
| AC earth voltage | 100.0V |
| AC earth current | 600.0A |
| Test Frequency | 128Hz/111Hz/105Hz/94Hz(AFC Auto) |
| Short circuit test current | AC 250mA max |
| Open circuit test voltage | AC 40V max |
| Manual range | auto range(V & A) |
| Auto power off | ● |
| Low battery indication | ● |
| Data hold | ● |
| Data storage | 2000 |
| LCD backlight | ● |
| Alarm function | ● |
| Full icon display | ● |
| Poor contact display | – |
| Over-range display | ● |
| 2-wire testing | ● |
| 3-wire testing | ● |
| 4-wire testing | ● |
| Disturbance voltage | – |
| Disturbance frequency | – |
| Earth resistance RH and RS test | – |
| Compensating resistance RK test | – |
| Certificates | ROW |