Endress+hauser PMC51 Absolute and gauge pressure Cerabar
- Oil-free ceramic measuring cell
- Integrated membrane breakage detection
- Accuracy: Platinum ±0.075%
- SIL2 safety certified
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser PMC51: Versatile Pressure Sensing
The Endress+Hauser Cerabar PMC51 digital pressure transmitter stands as a testament to precision engineering, featuring a capacitive, oil-free ceramic measuring cell. This robust and intelligent device is primarily designed for both standard process and demanding hygienic applications, offering exceptional capabilities for pressure, level, volume, or mass measurement across a wide spectrum of liquids and gases. A key feature that underscores its superior design is the vacuum-proof ceramic membrane, which incorporates integrated breakage detection, guaranteeing an elevated degree of system safety and reliability. Furthermore, the PMC51 simplifies operations with its Quick Setup function, allowing for easy adjustment of the measuring range. This not only streamlines commissioning but also significantly reduces associated costs and saves valuable time, making it an efficient solution for critical industrial processes.
Safety Assured: Integrated Breakage Detection
One of the most critical safety features of the Endress+Hauser Cerabar PMC51 is its innovative vacuum-proof ceramic membrane with integrated breakage detection. This intelligent design element provides an unparalleled level of process safety, especially in applications involving vacuum or potentially hazardous media. Should any integrity issue arise with the membrane, the integrated detection system immediately signals an anomaly, preventing potential leaks, contamination, or process disruptions. This proactive safety mechanism ensures continuous operational integrity and protects both personnel and equipment. The PMC51’s commitment to safety is further reinforced by its compliance with SIL2 according to IEC 61508 / IEC 61511, making it an ideal choice for safety-instrumented systems where reliability and risk mitigation are paramount.
Robust Design: Corrosive, Abrasive Media
The Endress+Hauser Cerabar PMC51 is engineered to excel in challenging environments, particularly those involving corrosive and abrasive media. Its core strength lies in the overload-resistant, high-purity ceramic sensor (99.9% Al2O3), which is inherently robust and highly resistant to chemical attack and wear. This makes the PMC51 an ideal choice for processes where traditional sensors might quickly degrade. Furthermore, its oil-free ceramic measuring cell is specifically designed to be condensation-resistant, a crucial feature for hygienic applications where maintaining cleanliness and preventing microbial growth is essential. This unique combination of material science and design ensures long-term stability and reliability, minimizing maintenance and extending the operational life of the transmitter in even the harshest industrial settings.
Simplified Commissioning: User-Friendly Interface
The Endress+Hauser Cerabar PMC51 prioritizes user experience with its exceptionally easy menu-guided commissioning via a local display. This intuitive interface allows for quick and straightforward setup, significantly reducing the time and effort typically required for instrument configuration. The Quick Setup feature with an adjustable measuring range further enhances this ease of use, enabling operators to tailor the device to specific process requirements efficiently. Beyond local operation, the PMC51 supports multiple communication protocols, including 4 to 20mA with HART, PROFIBUS PA, and FOUNDATION Fieldbus. This versatility ensures seamless integration into existing control systems, offering flexible monitoring and control options. The user-centric design of the PMC51 minimizes training needs and accelerates deployment, making it a highly efficient solution for modern industrial automation.
Versatile Applications: Pressure, Level, Flow
The Endress+Hauser Cerabar PMC51’s versatility extends to a broad range of critical applications across various industries. Its ability to accurately measure pressure, level, volume, or mass in liquids and gases makes it indispensable. In the food and beverage industry, its hygienic approvals (3A, EHEDG) and condensation resistance make it perfect for sterile processes, such as monitoring tank levels of milk or juice. In chemical plants, it excels in measuring the pressure of corrosive media, thanks to its robust ceramic sensor. For water treatment facilities, it can monitor pump suction pressures or filtration systems. Furthermore, its suitability for vacuum applications and integrated membrane breakage detection provides additional layers of security in sensitive processes, highlighting its adaptability from standard industrial use to highly specialized hygienic demands.
Robust Construction: Enduring Diverse Environments
The Endress+Hauser Cerabar PMC51 is built for endurance, featuring a robust construction designed to thrive in diverse industrial environments. Its single-chamber housing is available in either durable aluminum or high-grade 316L stainless steel, offering excellent protection against environmental factors and corrosive atmospheres. The transmitter supports a wide range of process connections, including threads, flanges, and various hygienic connections (e.g., Tri-Clamp, DIN11851, Varivent N), ensuring broad compatibility with existing plant infrastructure. It can withstand process temperatures from -40°C to +130°C (-40°F to +266°F), with a short-term resistance up to +150°C (302°F) for one hour, making it suitable for applications requiring sterilization. This comprehensive material and design flexibility ensures reliable performance and longevity, even under challenging operational conditions.
Specifications
-
easuring principle
Absolute and gauge pressure
-
Characteristic
Smart and reliable pressure transmitter with capacitive measuring cell and ceramic process isolating diaphragm Ceraphire)
-
Supply voltage
4…20 mA HART
11,5…45V DC (Non Ex):
Ex ia: 11,5…30V DC
PROFIBUS PA:
9…32 V DC (Non Ex)
FOUNDATION Fieldbus:
9…32 V DC (Non Ex) -
Reference Accuracy
Standard 0.1%
Platinum 0.075% -
Long term stability
0.2% of URL/ year
0.4% of URL/ 5 years
0.5% of URL/ 10 years -
Process temperature
-40°C…+130°C
(-40°F…+266°F
+150°C for 1h
(+302°F for 1h) -
Ambient temperature
-40°C…+85°C
(-40°F…+185°F) -
Measuring cell
100 mbar…40 bar
(1.5 psi…600 psi)
relative/ absolute -
Smallest calibratable span
10 mbar (0.15 psi)
-
Vacuum resistance
0 mbar abs.
-
Max. Turn down
20:1
-
Max. overpressure limit
60 bar (900 psi)
-
Process connection
Thread:
G1/2…G2, R1/2, MNPT1/2
Flange:
DN25…DN80,
ASME 1″…4″,
JIS 10K -
Process connection hygienic
Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD -
Material process membrane
Ceramic
-
Material gasket
Viton, EPDM, NBR, Kalrez
-
Fill fluid
None, dry measuring cell
-
Material housing
Die-cast aluminum,
AISI 316L -
Communication
4…20 mA
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
IO-Link -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
-
Safety approvals
SIL
-
Design approvals
EN10204-3.1
NACE MR0175 -
Hygienic approvals
CoC ASME-BPE
3A, EHEDG -
Marine approvals
GL/ ABS/ LR/ BV/ DNV
-
Drinking water approvals
NSF
-
Successor
PMC51B