Endress+Hauser CCS51: Free Chlorine Monitoring Solution

The Endress+Hauser CCS51 is a robust and low-maintenance sensor meticulously designed for the precise measurement of free chlorine. This sensor offers high-precision readings and exceptional long-term stability, making it an ideal choice for monitoring disinfection in drinking water, various process water applications, and even pool water. Its capability to ensure consistent disinfection monitoring extends to scenarios with low water volumes, highlighting its versatility. Characterized by extremely fast response times, this analog free chlorine sensor facilitates efficient process control and contributes significantly to overall process safety. The CCS51 also guarantees continuity for existing analog free chlorine measuring points, making it a reliable upgrade or replacement.

Ensuring Reliable Disinfection in Drinking Water

The primary application for the Endress+Hauser CCS51 free chlorine sensor is in drinking water treatment facilities, where it plays a critical role in ensuring reliable disinfection. Maintaining the correct concentration of free chlorine is paramount for public health, as it effectively eliminates harmful bacteria and viruses. The CCS51 provides accurate and stable measurements, allowing water utilities to continuously monitor and adjust chlorine levels to meet stringent regulatory standards. This continuous, precise monitoring ensures that the water delivered to consumers is safe, clean, and free from pathogenic microorganisms, upholding the highest standards of water quality.

Hygienic and Safe Packaging in Process Water

In numerous industrial settings, particularly within the food and beverage sectors, process water requires meticulous control of free chlorine for hygienic and safe packaging and bottling of products. The CCS51 sensor is perfectly suited for these demanding applications. Its fast response time and accurate measurements enable continuous monitoring of chlorine levels, ensuring that process water meets the necessary disinfection criteria. This precision helps prevent microbial contamination, safeguarding product quality, extending shelf life, and ensuring consumer safety, all while maintaining compliance with rigorous hygiene standards.

Detecting Free Chlorine in Utilities Operations

The Endress+Hauser CCS51 is also invaluable in various utilities operations where detecting the absence or presence of free chlorine is crucial. This could include monitoring water lines to ensure proper disinfection has occurred or to verify that chlorine has been completely removed before discharge or further processing. The sensor’s reliability and precision make it an ideal tool for these verification tasks, providing operators with immediate and accurate information. Such capabilities are essential for maintaining operational integrity, preventing system contamination, and ensuring compliance with specific utility protocols and environmental regulations.

Efficient Disinfectant Dosing for Pool Water

For swimming pools and aquatic facilities, maintaining optimal free chlorine levels is essential for bather safety and water clarity. The CCS51 sensor facilitates efficient disinfectant dosing by providing precise and rapid measurements of free chlorine. This allows pool operators to accurately adjust chlorine input, preventing both under-dosing (which can lead to insufficient disinfection) and over-dosing (which can cause skin and eye irritation, and material degradation). The sensor’s fast response time ensures that changes in chlorine demand are quickly detected and addressed, leading to safer, more comfortable, and cost-effective pool management.

Fast Response for Efficient Process Control

The Endress+Hauser CCS51 sensor boasts an exceptionally fast response time, with a t90 value of less than 25 seconds. This rapid reaction capability is fundamental for providing an accurate and real-time view of the process, which is critical for efficient process control. Operators can react promptly to any detected changes in free chlorine concentration, enabling immediate adjustments to disinfectant dosing. This agility not only optimizes chemical usage but also significantly enhances overall process safety by ensuring that disinfection levels are consistently maintained within the desired parameters, thereby preventing potential contamination risks.

Increased Process Safety Through Precise Measurement

Process safety is significantly enhanced by the CCS51’s precise and long-term stable measurement capabilities. This sensor ensures consistent process monitoring of free chlorine levels, which is vital for preventing microbial growth and maintaining product integrity across various industries. The accuracy of the CCS51 allows for individually adapted disinfectant dosing, meaning that chemicals are applied exactly as needed, avoiding waste and potential environmental impact. This meticulous control contributes to higher product quality, reduced operational costs, and, most importantly, a safer operating environment for personnel and consumers alike.

Cost-Effective Monitoring with Low Maintenance Design

The amperometric design of the CCS51 sensor offers a distinct advantage in terms of cost of ownership, particularly when compared to more complex colorimetric measuring systems. Its low-maintenance nature translates into reduced operational expenses, as it requires less frequent calibration and upkeep. This economic benefit, combined with its high precision and long-term stability, makes the CCS51 an attractive and sustainable choice for continuous free chlorine monitoring. It ensures reliable performance without incurring excessive maintenance costs, contributing to a more efficient and budget-friendly management of water treatment processes.

Specifications

  • Measuring principle

    Free chlorine

  • Application

    Drinking water – to ensure reliable disinfection
    Process water – wide range of application due to large measuring range
    Food – to secure absence/presence of free chlorine
    Pool water -efficient dosing thanks to precise measurement

  • Characteristic

    Amperometric measurement of dissolved free chlorine

  • Measuring range

    Trace: 0 to 5 mg/l HOCl
    Standard: 0 to 20 mg/l HOCl

  • Measuring method

    – Closed, membrane covered measuring cell
    – Reduction of free chlorine at the cathode

  • Design

    Closed amperometric 2-electrode measuring cell with PVDF membrane

  • Material

    Sensor shaft: POM
    Membrane: PVDF
    Membrane cap: PVDF

  • Dimension

    Diameter: 25 mm (0.98 in)
    Length: 161 mm (6.34 in)

  • Process temperature

    +0 to 55 °C (32 to 130°F), non-freezing

  • Process pressure

    1 bar (14.5 psi)

  • Temperature sensor

    10k NTC

  • Connection

    analog with fixed cable

Data Sheet

Download Data Sheet Of: Endress+hauser CCS51 Analog free chlorine sensor