Endress+hauser CCS53E Digital total chlorine sensor Memosens
- Measures total chlorine reliably
- Fast reaction to process changes
- Memosens 2.0 technology
- Wide measurement range
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser CCS53E: Total Chlorine Measurement Mastery
The Endress+Hauser CCS53E Memosens sensor is engineered for the precise and continuous measurement of total chlorine, offering invaluable insights into residual disinfectant levels in discharge and process water. This sophisticated sensor provides reliable readings even after periods where no chlorine has been present, enabling accurate measurement of “zero” chlorine conditions. By leveraging the advanced Memosens 2.0 technology, the CCS53E seamlessly combines maximum process and data integrity with straightforward operation. This makes it an ideal foundation for implementing predictive maintenance strategies, enhancing operational efficiency, and embracing the possibilities of IIoT connectivity for smarter water management.
Diverse Applications for Total Chlorine Monitoring
The Memosens CCS53E sensor proves its value across a broad spectrum of applications, ensuring effective chlorine management in critical sectors. In wastewater treatment plants, it is indispensable for controlling outlet water quality, enabling the safe reuse of treated water and ensuring compliance with environmental discharge regulations. Within the process water systems of various industries, it reliably detects chlorine, acting as a crucial safeguard against potential damage to sensitive equipment, such as cooling towers. For the food and beverage industry, the CCS53E is essential for maintaining hygienic filling processes and upholding high food quality standards in washing water, while also protecting delicate membranes in reverse osmosis systems.
Uninterrupted Measurement for Regulatory Compliance
A significant benefit of the CCS53E sensor is its remarkable ability to maintain continuous measurement even after periods of no chlorine presence. Unlike some systems that might be deactivated or require lengthy re-polarization, the CCS53E reacts immediately when chlorine becomes present again. This uninterrupted measurement capability is vital for ensuring prompt responses to process changes and guaranteeing consistent compliance with stringent regulatory requirements. By providing a continuous stream of accurate data, operators can confidently manage disinfection levels and demonstrate adherence to all applicable standards and guidelines.
Reducing Costs with Smart Sensor Technology
The Endress+Hauser CCS53E is designed as a low-maintenance, amperometric sensor, a feature that substantially reduces the total cost of ownership for the measuring point. This advantage is particularly pronounced when contrasted with traditional colorimetric measuring systems, which often require more frequent servicing, calibration, and consumable replacements. The inherent robustness of the CCS53E, coupled with the efficiency of Memosens 2.0 technology for sensor exchange and faster polarization, contributes to increased process up-time. This minimizes operational disruptions and associated costs, making it a highly efficient and cost-effective solution for ongoing monitoring needs.
Enhancing Process Uptime and Reliability
Process up-time is a critical factor in maintaining operational efficiency and productivity, and the CCS53E sensor is engineered to maximize it. The Memosens 2.0 technology facilitates a true plug-and-play experience for sensor exchange. By allowing for pre-calibration of the sensor in a controlled laboratory environment, users can swiftly swap out a sensor directly in the process with minimal downtime. Furthermore, the polarization time is significantly reduced with Memosens 2.0, meaning the sensor is ready for accurate measurement almost immediately after installation. This rapid readiness and ease of replacement contribute to higher overall system reliability and availability.
Versatile Measurement for Diverse Needs
The CCS53E offers a wide measurement range, making it suitable for a variety of applications and concentrations of total chlorine. Whether the need is to detect minimal traces or measure up to 20 mg/l of total chlorine, the sensor provides accurate and reliable results. This versatility ensures that the sensor can be effectively deployed in different scenarios, from strict regulatory monitoring in wastewater and drinking water to process optimization in food and beverage applications and protecting sensitive equipment like reverse osmosis membranes. The ability to accurately measure from zero up to higher concentrations enhances its utility across the board.
Integrated Monitoring with Liquiline Transmitter
The CCS53E sensor is designed for seamless integration into broader water quality monitoring frameworks. When connected to the Liquiline multiparameter transmitter, it allows for the easy combination of total chlorine measurements with other relevant parameters of liquid analysis, such as pH and ORP. This integrated approach provides a comprehensive overview of water quality, enabling users to correlate different measurements and gain deeper insights into process conditions. Such a consolidated view simplifies data analysis, facilitates more informed decision-making, and enhances the overall effectiveness of water treatment and management strategies.
Your Trusted Partner: tpt24 for Global Access
For those seeking the highest standards in total chlorine measurement, the Endress+Hauser CCS53E Memosens sensor stands out, and tpt24 is your premier global online destination for this exceptional product. We are proud to be recognized as the world’s leading online store, offering not only the CCS53E but also an unwavering commitment to product authenticity and superior quality. Our mission is to ensure that every customer, irrespective of their location, receives their order reliably and with complete confidence. Partner with tpt24 for your Endress+Hauser needs and benefit from our global reach, guaranteed quality, and dedication to exceptional customer service.
Specifications
-
Measuring principle
Total chlorine
-
Application
Wastewater treatment plants, disinfection monitoring and control in wastewater outlet, reuse of outlet water
utilities of all industries
drinkingwater to regulate disinfection
all disinfection measuring points
swimming pool with efficient disinfection
Food and Beverage, cleaning water or zero chlorine applications for reverse osmosis, -
Characteristic
Amperometric measurement of total chlorine
-
Measuring range
0 to 5 mg/l total chlorine or
0 to 20 mg/l total chlorine -
Measuring method
Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines)
All components are reduced at the working electrode
Almost pH independent -
Design
Closed amperometric 2-electrode measuring cell with PET membrane
-
Material
Sensor shaft: POM
Membrane: PET/PVDF
Mebrane cap: PVDF -
Dimension
Diameter: 25 mm (0.98 in)
Length: 161 mm (6.34 in) -
Process temperature
0 to 55 °C , non-freezing
(32 to 130 °F) -
Process pressure
1 bar relative (14,5 psi relativ)
Max. 2 bar (max. 29 psi) -
Temperature sensor
10k NTC integrated (Memosens)
-
Connection
Inductive, digital connection head with Memosens 2.0