Endress+Hauser FDR56 Microwave barrier transmitter Soliwave
- Range: Max. 100m (328ft)
- Ambient Temp: -40°C to +70°C
- Process Connection: 1-1/2″ R, G, NPT
- Supply: 85 to 253 VAC
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser FDR56: Reliable Point Level Detection
The Endress+Hauser FDR56 microwave barrier offers contact-free point level detection. It is suitable for installation in containers, conduits, shafts, or free fall shafts, providing flexibility in various industrial setups. It interacts with the Soliwave FQR56 emitter for optimal performance.
Measurement Through Non-Metallic Container Materials
This sensor enables measurement through non-metallic container materials from the outside. This feature expands the FDR56’s applicability, allowing for measurement without direct contact with the process material. Ideal for use with all types of bulk solids.
Versatile Application Across Various Bulk Solids
The FDR56 offers versatile application across various bulk solids. Typical materials include wood chips, wood dust, flour, plaster, cement, ash, paper, cardboard shred, gravel, sand, dried powders, bags, and boxes, making it suitable for diverse industrial needs.
Highly Reliable and Cost-Effective Solution
Benefit from a highly reliable and cost-effective solution. The flush-mounted and non-contact installation, combined with signal strength indication, enhances measurement reliability. Its mechanically robust design ensures cost savings over the product’s life cycle.
Savings Over the Product’s Life Cycle
The FDR56 provides savings over the product’s life cycle with its wear-free operation and optional process-wetted ceramic sensor diaphragm. The device offers a long serviceable life and is maintenance-free, reducing long-term operational costs.
Electronics Housing Rotatable for Optimum Positioning
The electronics housing is rotatable for optimum positioning by 360°, allowing easy adjustment after installation. This ensures that the device can be placed in the most advantageous position, optimizing measurement accuracy and efficiency.
Premier Online Store for Authentic Products
For the Endress+Hauser FDR56, Premier Online Store for Authentic Products is TPT24. As the world’s leading online store, TPT24 guarantees the authenticity and quality of this product. Receive your product anywhere, enjoying secure and prompt worldwide delivery.
Adaptable Installation Using Existing Accessories
The FDR56 is adaptable installation using existing accessories. Mechanically compatible with the FQR50/FDR50 microwave barrier, it allows existing process connections to continue to be used. Accessories like adapter flanges, installation brackets, and sight glasses are also compatible.
Specifications
-
Measuring principle
Microwave barrier
-
Characteristic / Application
Transceiver
Non-contact point level detection and flow monitoring
Detecting, counting and positioning of objects
Monitoring of material transfer points
Detection and analysis of deposits and contamination
Installation:
Non-contact installation (transmission window) or front-flush installation (contact) -
Specialities
Measuement range: max. 100 m
-
Supply / Communication
85 … 253 VAC
20 … 60 VDC/ 20 … 30 VAC -
Ambient temperature
-40°C…+70°C
(-40°F…+158°F) -
Process temperature
Non-contact installation: any
Within installation:
-40°C…+70°C (-40°F…+158°F)
With high temperature adapter:
up to +450°C (+842°F) -
Process pressure / max. overpressure limit
Non-contact installation: any
Within installation:
0.5 bar … 6.8 bar (7.2 psi … 99 psi) abs.
With high pressure adapter:
up to +21 bar (+305 psi) abs. -
Min. density of medium
Solid weight: > 10 g/l
-
Main wetted parts
Non-contact installation:
no wetted parts
Within installation:
316Ti or Aluminium;
PTFE or Ceramic -
Process connection
1-1/2″ R, 1-1/2″ G, 1-1/2″ NPT
-
Process connection hygienic
Non-contact installation
-
Communication
Relays SPDT
Solid-State-Relaiy
4 … 20 mA -
Certificates / Approvals
ATEX, CSA C/US, IEC Ex
-
Design approvals
EN10204-3.1
-
Options
Sight glass
High temperature adapter
High pressure adapter
Installation bracket
FAR50, FAR51, FAR52, FAR53, FAR54, FAR55 -
Components
Transmitter: FQR56
-
Application limits
Solid weight: < 10 g/l