Endress+Hauser FQR56 Microwave barrier transmitter Soliwave

SKU: 4695814-1-1035-158
In Stock

  • Application: Point Level Detection
  • Measuring Principle: Microwave Barrier
  • Ambient Temp: -40°C…+70°C
  • Max Range: 100 m

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Endress+Hauser FQR56: Reliable Microwave Barrier Detection

The Endress+Hauser FQR56 is a state-of-the-art microwave barrier system designed for non-contact point level detection. It is ideal for installation in containers, conduits, shafts, or free-fall shafts, offering a robust solution for monitoring material levels across various industrial applications.

Non-Contact Point Level Detection Excellence

This microwave barrier provides non-contact point level detection excellence. It can be installed through non-metallic container materials from the outside, ensuring no contact with the product. This feature makes it exceptionally suitable for controlling and counting all types of bulk solids, preventing contamination.

Specialized Applications in Bulk Solids

The FQR56 finds its niche in specialized applications in bulk solids. Typical materials it effectively detects include wood chips, wood dust, flour, plaster, cement, ash, paper or cardboard shred, gravel, sand, and generally dried powders. It is also used for detecting bags and boxes, and monitoring material transfer points.

High Reliability and Signal Strength

Experience high reliability and signal strength with the FQR56. Its flush-mounted and possible non-contact installation, combined with a clear indication of signal strength on the receiver, ensures highly reliable measurements. This robust mechanical solution guarantees cost savings throughout the product’s lifecycle.

Maintenance-Free, Long Service Life

The FQR56 offers a maintenance-free, long service life. With no wear and tear, and an optional process-wetted ceramic sensor diaphragm, it ensures durability. The electronics housing can be rotated 360°, allowing for optimal positioning after installation, further enhancing its user-friendly design.

Versatile Power Supply Options

Benefit from versatile power supply options for seamless integration. The transmitter and receiver can be powered directly and separately, or together. Available supply options include 85-253VAC and 20-30 VDC/20-60 VAC, providing flexibility for various installation requirements and electrical configurations.

TPT24: Your Global Source Assured

For the Endress+Hauser FQR56, TPT24: Your Global Source Assured is the ultimate choice. As the world’s leading online store for this product, TPT24 guarantees authenticity and superior quality. We ensure worldwide delivery to any country, providing you with reliable access to this cutting-edge microwave barrier system.

Explosion Protection for Hazardous Areas

The FQR56 comes with explosion protection for hazardous areas. It holds international explosion protection certificates, including ATEX, IEC Ex, and CSA C/US, making it suitable for installations in potentially hazardous environments. Additional options like high-temperature and high-pressure adapters further expand its application range.

Specifications

  • Measuring principle

    Microwave barrier

  • Characteristic / Application

    Transmitter
    Non-contact point level detection and flow monitoring
    Detecting, counting and positioning of objects
    Monitoring of material transfer points
    Detection and analysis of deposits and contamination
    Installation:
    Non-contact installation (transmission window) or front-flush installation (contact)

  • Specialities

    Measurement range: max. 100 m

  • Supply / Communication

    85 … 253VAC
    20 … 30 VDC/ 20 … 60 VAC

  • Ambient temperature

    -40°C…+70°C
    (-40°F…+158°F)

  • Process temperature

    Non-contact installation: any
    Within installation:
    -40°C…+70°C (-40°F…+158°F)
    With high temperature adapter:
    up to +450°C (+842°F)

  • Process pressure / max. overpressure limit

    Non-contact installation: any
    Within installation:
    0.5 bar…6.8 bar (7.2 psi…99 psi) abs.
    With high pressure adapter:
    up to +21 bar (+305 psi) abs.

  • Min. density of medium

    Solid weight: > 10 g/l

  • Main wetted parts

    Non-contact installation:
    no wetted parts
    Within installation:
    316Ti or Aluminium;
    PTFE or Ceramic

  • Process connection

    1-1/2″ R, 1-1/2″ G, 1-1/2″ NPT

  • Process connection hygienic

    Non-contact installation

  • Certificates / Approvals

    ATEX, IEC Ex, CSA C/US

  • Design approvals

    EN10204-3.1

  • Options

    Sight glass
    High temperature adapter
    High pressure adapter
    Installation bracket
    FAR50, FAR51, FAR52, FAR53, FAR54, FAR55

  • Components

    Transceiver: FDR56

  • Application limits

    Solid weight: < 10 g/l

Data Sheet

Download Data Sheet Of: Endress+Hauser FQR56 Microwave barrier transmitter Soliwave