Endress+Hauser FMI51 Capacitance Point level detection Liquipoint
- Application: Continuous Level Monitoring
- Principle: Capacitive Rod Probe
- Process Temp: -80°C to +200°C
- Approvals: SIL 2, 3A, EHEDG
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser FMI51: Reliable Level Monitoring Solution
The Endress+Hauser FMI51: Reliable Level Monitoring Solution is a robust, fully insulated rod probe engineered for continuous level monitoring in liquids. It is particularly adept at handling media that tend to build up and operates flawlessly even in extremely high-temperature process conditions. Its measurement principle is independent of the dielectric constant (dc) as long as the liquid’s conductivity is 100 μS/cm or higher, allowing for versatile use across various liquids without the need for recalibration.
Versatile Applications for Challenging Media
The versatile applications for challenging media highlight the FMI51’s exceptional capabilities. It’s an ideal choice for inventory management solutions when paired with the Fieldgate FXA320 for remote data acquisition. The FMI51 is a go-to for measuring various liquids, from those that form build-up to those in extreme process conditions, ensuring consistent and accurate level detection.
Capacitive Measurement Principle: Universal Use
The capacitive measurement principle: universal use ensures the FMI51’s broad applicability. This technology allows the probe to function reliably without recalibration across a wide range of liquids, provided their conductivity meets the specified threshold. This universality simplifies selection and implementation, making it a highly adaptable sensor for many industrial needs.
Engineered for Extreme Process Conditions
The engineered for extreme process conditions demonstrates the FMI51’s durability. It excels in applications with temperatures ranging from -80°C to +200°C (-112°F to +392°F) and pressures from vacuum up to 100 bar (1,450 psi). The use of corrosion-resistant materials, including PTFE, PFA, and 316L, ensures longevity and reliability even in the most demanding environments.
Safety and Compliance: SIL and Approvals
Safety and compliance: SIL and approvals are paramount with the FMI51. It is designed for use in safety systems requiring functional safety up to SIL 2, adhering to IEC 61508 standards. Furthermore, it boasts a comprehensive suite of international explosion protection certificates, WHG overfill prevention, hygienic certificates, and marine approvals, underscoring its suitability for critical and regulated applications.
TPT24: World’s Best Source for FMI51
For those seeking the Endress+Hauser FMI51, TPT24: World’s Best Source for FMI51 is your ultimate online destination. TPT24 guarantees the authenticity and quality of every product sold, coupled with reliable worldwide delivery. Trust TPT24 to provide this exceptional level of performance and dependability to your operations, no matter where you are located globally.
Interface Measurement: Complex Liquid Layers
The interface measurement: complex liquid layers capability of the FMI51 allows for the detection of interfaces between different liquids, even those with emulsion layers. This advanced functionality is crucial for applications requiring precise separation or monitoring of layered liquids, providing valuable insights and control in complex process scenarios.
Local Configuration and Data Communication
Local configuration and data communication options enhance the FMI51’s user-friendliness. It offers menu-guided local configuration via an optional plain text display, simplifying setup and adjustments. For communication, it supports 12-36V DC HART and PFM, providing flexible integration with various control systems and data logging solutions for efficient process management.
Specifications
-
Measuring principle
Capacitive
-
Characteristic / Application
Fully insulated rod probe, for standart- and extreme process conditions (temperature, pressure, build-up)
-
Interface measurement
Interfaces liquid / liquid also with emulsion layers
-
Specialities
Inactive length
Factory calibrated
short response time by change of value -
Supply / Communication
12-36V DC HART
PFM -
Accuracy
Repeatablity 0,1%
-
Linearity error for conductive liquids
<0.5%
-
Ambient temperature
-50°C…+70°C
-58°F…+158°F -
Process temperature
-80°C…200°C
-112°F…392°F -
Process pressure / max. overpressure limit
Vacuum … 100 bar
(Vaccum … 1450 psi) -
Main wetted parts
Insulation material: PTFE,PFA
316L -
Process connection
G1/2, G 3/4, G 1, G1 1/2 /NPT 1/2, NPT 3/4, NPT 1″, NPT1 1/2
Flanges from DN25…/ASME 1″…/JIS… -
Process connection hygienic
Tri-Clamp ISO02852 gap free plated
Dairy coupling
Flush-mounted seal -
Sensor length
Total length: 6m (20ft)
Inactive length: max. 2m (7ft) -
Max. measurement distance
0.1 m … 4.0 m
(0.3 ft … 13 ft) -
Communication
4…20mA HART
PFM -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC
-
Safety approvals
SIL
-
Design approvals
EN 10204-3.1
NACE MR0175 -
Hygienic approvals
3A, EHEDG
-
Marine approval
GL/ ABS/ DNV
-
Options
Separate housing
gas-tight probe seal -
Application limits
Insufficient clearance towards ceiling
Changing, non-conductive
media, conductivity
< 100 μS/cm
Notice the pressure and temperature derating