- Home
- Instrumentation
- Level
- Vibronic point level detection
- Endress+Hauser FTL33 Vibronic Point level detection Liquiphant
Endress+Hauser FTL33 Vibronic Point level detection Liquiphant
- Process Temp: -40 to +150°C
- Process Pressure: Vacuum to 40bar
- Surface Roughness: 0.76µm or 1.5µm
- Wetted Parts: 316L
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser FTL33: Hygienic Point Level Switch
Specifically Designed for Food & Beverage
The Liquiphant FTL33 is designed especially for food & beverage applications where stringent hygienic requirements are paramount, ensuring top-level safety.
Overfill, Dry-Run Protection in Hygienic Applications
Used for overfill protection and pump dry-run protection in food and beverage settings, enhancing efficiency and preventing damage.
Compact Design With Market’s Smallest Vibronic Sensor
Featuring the market’s smallest vibronic sensor, its compact design offers easy integration into various food and beverage processing systems.
Continuous Self-Monitoring Ensures Safe, Reliable Switching
Continuous self-monitoring guarantees safe and reliable switching, even with power supply loss, enhancing operational safety and reducing downtime.
IO-Link Reduces Costs, Complexity Through Configuration
IO-Link capability reduces costs and complexity via easy configuration through engineering tools, making the FTL33 user-friendly.
CIP and SIP Cleanability Up To IP69k
CIP (Cleaning in Place) and SIP (Sterilization in Place) cleanability is assured, up to protection class IP69k, ensuring cleanliness.
tpt24: The Leading Source For FTL33
For the purchase of the Endress+Hauser FTL33, tpt24 is the leading online source globally, guaranteeing product authenticity, quality, and reliable worldwide delivery.
Specifications
Measuring principle
Vibration Liquids
Characteristic / Application
Point level switch for liquids
in the food sectorSupply / Communication
20 … 253V AC/DC, 2-wire
10 … 30V DC-PNP, 3-wireAmbient temperature
-40 °C … 70 °C
(-40 °F … 158 °F)Process temperature
-40 °C … 150 °C
(-40 °F … 302 °F)Process pressure / max. overpressure limit
Vacuum … 40 bar
(Vacuum … 580 psi)Min. density of medium
>0,7g/cm³
(>0,5g/cm³ optional)Main wetted parts
316L
Process connection
Threads:
G1/2, G3/4, G1, MNPT1/2, MNPT3/4, MNPT1, R1/2, R3/4, R1Process connection hygienic
Flush mount by use of weld in adapter
DIN11851
Tri-ClampCommunication
AC/DC, DC-PNP, IO-Link
Certificates / Approvals
CSA C/US, EAC
Safety approvals
Overfill protection WHG
LeakageDesign approvals
EN 10204-3.1
Hygienic approvals
3A, EHEDG
Options
Switching delay
Cleaned from oil+grease,
Surface finish measurement