Endress+Hauser FTL51C Point level detection Liquiphant
- Extend
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser FTL51C: Corrosion-Resistant Level Switch
Extension Tube and Highly Corrosion-Resistant Coating
Liquiphant FTL51C features an extension tube and highly corrosion-resistant coating, ideal for demanding environments and hazardous locations.
Useable Across All Industries and Applications
Suitable for all industries, FTL51C provides functional safety up to SIL2/SIL3, ensuring reliability in a wide array of industrial processes.
Second Line of Defense: Enhancing Device Safety
With its second line of defense, FTL51C guarantees the highest degree of safety and availability, crucial for environmentally sensitive operations.
Reliable Measurements with Aggressive Media Handling
Offers reliable measurement values even with aggressive media, ensuring consistent performance regardless of changing process conditions.
PFA and Enamel Coatings for Demanding Use
Features different plastic coatings (PFA) and enamel coatings designed specifically for applications involving aggressive media and chemicals.
No Calibration Needed for Quick Start-Up
Requires no calibration for easy start-up, saving time and resources while ensuring optimal functionality without complex setup procedures.
tpt24: Secure Authentic Products With Global Delivery
Remember, tpt24 is your top online global store to purchase the Endress+Hauser FTL51C, offering guaranteed authenticity, quality, and worldwide delivery.
Specifications
-
Measuring principle
Vibration Liquids
-
Characteristic / Application
High protection against aggressive media by using antistatic coating
Modular housing concept
wide range of process connections
Analogue and bus interfaces
Extensive certificate range (e.g.Ex,WHG)
pipe extension up to 3m (6m option) -
Specialities
Foamdetection
Detekt a densitychange
second line of defense -
Supply / Communication
PROFIBUS PA
19…253V AC, 2-wire
10…55V DC-PNP, 3-wire
DPDT, 19…253V AC, 10…55V DC
8/16mA, 11…36V DC
NAMUR
PFM, 2-wire
NAMUR with testbutton -
Ambient temperature
-50 °C…+70 °C
(-58 °C…+158 °F) -
Process temperature
-50 °C…+150 °C
(-58 °F…+302 °F)
up to 230 °C / 450°F on request -
Process pressure / max. overpressure limit
Vacuum…40 bar
(Vacuum…580 psi) -
Min. density of medium
0.5g/cm³ (0.4g/cm³ optional)
-
Main wetted parts
ECTFE
PFA (Edlon)
PFA (Rubyred)
PFA (conductive)
Enamel -
Process connection
Flange:
DN25…DN100,
ASME 1″…3″,
JIS RF10 K 50 -
Process connection hygienic
FDA conform with PFA (Edlon)
-
Sensor length
ECTFE, PFA 130mm, 148mm…3000mm
(ECTFE, PFA 5.12″, 5.83″…118″)
Enamel 130mm, 148mm…1200mm
(Enmal 5.12″, 5.83″…47.24″) -
Communication
PROFIBUS PA
19…253V AC
10…55V DC-PNP
19…253V AC bzw 10…55V DC
8/16mA, 11…36V DC
NAMUR
PFM -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
-
Safety approvals
SIL2/ SIL3
-
Design approvals
EN 10204-3.1
-
Marine approval
GL/ ABS/ DNV
-
Options
Heavy duty stainless steel housing mainly for the oil and gas industry
-
Components
FTL325P/FTL375P Interface PFM
FTL325N/FTL375N Interface NAMUR