Endress+Hauser FTL85 Vibronic Point level detection Liquiphant
- Sensor Coating: Enamel, ECTFE, PFA
- Process Temp: -50 to +150°C
- Process Pressure: Vacuum to 40bar
- Safety Approval: SIL3
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser FTL85: Coated for Corrosive Environments
Coated Point Level Switch for Hazardous Areas
The Liquiphant FTL85 is a state-of-the-art coated point level switch, engineered for challenging hazardous areas and boasting all essential international certifications.
FailSafe Overfill Protection with SIL3 Capability
It offers FailSafe overfill protection in applications demanding functional safety up to SIL3, all within a single, highly reliable and uniquely protected device.
Reliable Measurement Unaffected by Media Changes
You can count on consistently reliable measurement values, utterly impervious to changing media properties, flow, turbulence, gas bubbles, foam, vibrations, or stubborn buildup.
Superior Corrosion Resistance with Advanced Coatings
Equipped with high corrosion-resistant coatings of enamel, ECTFE, and various PFA materials, the FTL85 thrives in aggressive chemical environments.
Designed for Safety Systems Requiring Functional Compliance
This device is meticulously designed for safety systems requiring functional safety up to SIL3, adhering strictly to IEC 61508 Ed.2.0 and related standards.
Effortless Integration with 4-20mA Interface
Its standard 4-20mA interface allows for seamless integration via a switching unit or direct connection to a safety PLC, simplifying your system setup.
tpt24: Your Global Source for Authentic Products
For your Endress+Hauser FTL85, tpt24 is the top global online store, guaranteeing authenticity, quality, and reliable worldwide delivery.
Specifications
-
Measuring principle
Vibration Liquids
-
Characteristic / Application
Coated point level switch for MIN and MAX safety applications up to SIL3,
Dual Sealing/ Second line of defense,
Modular housing concept -
Specialities
Outstanding features:
– permanent LIVE signal monitors function safety
– failsafe design and
– high availability of the measuring values -
Supply / Communication
2-wire 4…20 mA
-
Ambient temperature
-50°C…+70°C
(-58°F…+160°F) -
Process temperature
–50°C…+150°C
(–58°F…+300°F) -
Process pressure / max. overpressure limit
Vacuum…40 bar
(580 psi) -
Min. density of medium
Density from 0.4 g/cm3
(0.4 SGU) -
Main wetted parts
With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials
-
Process connection
Flange:
DN25…DN100,
ASME 1″…4″,
JIS 10K…20K -
Sensor length
Extension pipe up to 3 m (9.8 ft)
-
Communication
2-wire 4…20 mA
-
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, EAC
-
Safety approvals
Overfill protection WHG
Leakage Detection
SIL3 -
Options
AlloyC Material
PWIS free
Pressure tight feed through
Weather protection -
Components
Nivotester FTL825, Transmitter