Endress+Hauser FTL64 Liquiphant reliable detection at high temperatures
- Process Temp: -60 to +280°C
- Process Pressure: Vacuum to 100bar
- Wetted Parts: 316L, Alloy
- Sensor Length: Up to 6m
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser FTL64: High Temperature, High Pressure
Strong Focus on High Temperature Applications
The Liquiphant FTL64 is engineered for demanding high-temperature applications, ensuring reliable and safe operations in extreme environments.
Reliability and Safety With Easy Proof Testing
FTL64 offers reliability and safety (SIL compliant) with easy proof testing, meeting IEC 61508, API 2350, and WHG standards.
Safe Measuring in Challenging High Temperature Environments
This vibronic device provides safe and active measuring technology, specifically designed for applications involving elevated temperatures.
Proven Point Level Detection for Tank Protection
It offers proven point level detection for both tank overfill and pump dry run protection, enhancing operational safety and efficiency.
Easy to Use With Digital Connectivity Options
The FTL64 is user-friendly, featuring digital connection for real-time data access, making monitoring and management straightforward.
Heartbeat Technology for Continuous Diagnostics
Benefit from Heartbeat Technology, allowing safe, continuous diagnostics and simple verification without process interruption.
tpt24: Your Global Partner for Authentic Products
For your Endress+Hauser FTL64, tpt24 is the top global online store, offering guaranteed authenticity, quality, and worldwide delivery.
Specifications
-
Measuring principle
Vibration Liquids
-
Characteristic / Application
Compact vibronic device for high pressure and high temperature applications,
Optional extension tube up to 6 m (19.7 ft),
Modular housing concept,
Wide range of certificates -
Specialities
Heartbeat Technology,
Bluetooth® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Second line of defense,
Temperature spacer for high process temperature,
Plug and play functionalities -
Supply / Communication
19…253V AC / 2-wire,
10…55V / DC-PNP 3-wire,
9…20V DC with relay DPDT,
19…253V AC or 19…55V DC with relay DPDT,
2-wire NAMUR,
2-wire PFM,
4-20mA HART -
Ambient temperature
-60 °C…+70 °C
(-76 °F…+158 °F) -
Process temperature
-60 °C…+280 °C
(-76 °F…+536 °F) -
Process pressure / max. overpressure limit
Vacuum…100 bar
Vacuum…1450 psi -
Min. density of medium
0.5 g/cm³
(0.4 g/cm³ optional) -
Main wetted parts
316L
Alloy -
Process connection
Threads:
3/4″, 1″
Flanges:
DN25…DN100
ASME 1″…4″
JIS 50A -
Sensor length
up to 6 m (19.7 ft)
-
Communication
2-wire direct load
HART
DC-PNP 3-wire
Relays
NAMUR
PFM
Bluetooth® wireless technology -
Certificates / Approvals
ATEX, IEC Ex, NEPSI, EAC Ex, KC, JPN Ex, INMETRO, UK Ex
-
Safety approvals
Overfill protection WHG
SIL2/ SIL 3 according to IEC 61508 -
Design approvals
EN 10204-3.1
NACE MR0175, MR0103
ASME B31.3 Process Piping
AD2000
CRN -
Marine approval
ABS/ LR/ BV/ DNV
-
Options
Ambient temperature down to -60 °C (-76 °F),
Heavy duty stainless steel housing,
Coating PFA (conductive) -
Components
FTL325P Interface PFM
FTL325N Interface NAMUR