  • Measuring Principle: Thermocouple
  • Protection Tube: Single Ceramic
  • Max Temp: +1,700 °C
  • Application: Furnace Measurement

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Endress+Hauser TAF12S: Reliable Single Ceramic Thermocouple

The Endress+Hauser TAF12S: Reliable Single Ceramic Thermocouple is expertly designed for measuring points with extremely high process temperatures, where conventional sensors would fail. Its robust single ceramic protection tube, crafted from advanced ceramic materials, shields the internal thermocouple from mechanical and chemical damage within the process. This design significantly extends sensor lifespan, leading to substantial cost savings on maintenance, improved product quality, and enhanced plant safety across critical industries like ceramic baking ovens, brickworks, porcelain production, and glass manufacturing.

Specialized Applications in High Heat Furnaces

The TAF12S finds its niche in specialized applications in high heat furnaces. It is specifically engineered for demanding environments such as ceramic baking ovens, brickworks, and porcelain production facilities, where temperatures can reach up to +1700 °C (+3092 °F). The single ceramic protection tube, made from materials like C610 or C799, provides essential protection for the thermocouple insert, whether it’s a single or double element housed in ceramic insulators. This specialization ensures accurate and stable measurements where others cannot perform.

Durable Ceramic Protection Enhances Longevity

Benefit from durable ceramic protection that enhances longevity with the TAF12S. The thermowell, constructed from high-quality ceramic materials, offers superior resistance to wear and chemical corrosion commonly found in high-temperature industrial processes. This protective layer ensures long-term stable measurements by safeguarding the sensor from process-induced degradation. Such resilience is paramount for maintaining operational efficiency and reliability in the glass and ceramics sectors, minimizing the frequency of sensor replacement and associated downtime.

Extended Sensor Life Through Material Innovation

The TAF12S achieves an extended sensor life through material innovation. By utilizing advanced ceramic materials for its protection tube, the assembly provides significantly increased wear and chemical resistance compared to standard metallic thermowells. This robust construction ensures that the internal thermocouple (Types S, R, or B) remains protected and performs stably over prolonged periods, even in aggressive process media. This focus on material science directly contributes to optimized life cycle costs for users.

Flexible Modular Design for Any Setup

This temperature assembly boasts a flexible modular design for any setup. The TAF12S allows for flexible product selection, accommodating either single or double thermocouple inserts within ceramic insulators. Its metric style and availability with various process connections, including G1/2″, G3/4″, G1″ compression fittings, and adjustable flanges, ensure seamless integration into diverse industrial systems. The capability to achieve immersion lengths of up to 2,500 mm further enhances its adaptability for specific furnace configurations.

Precise Measurement up to 1700 Degrees Celsius

The TAF12S delivers precise measurement up to 1700 degrees Celsius. It is optimized for use with Type S and Type R thermocouples for temperatures ranging from 0 °C to 1600 °C, and Type B thermocouples for the extreme range of 600 °C to 1700 °C. This wide and high-temperature operational capability, combined with accuracy classified as Class 2 according to IEC 60584, makes the TAF12S an ideal choice for critical applications in glass production, brick firing, and advanced ceramic manufacturing where exact temperature monitoring is vital.

tpt24: Your Premier Global Source

When sourcing the Endress+Hauser TAF12S, look no further than tpt24: your premier global source. As the world’s leading online store for this specialized product, tpt24 guarantees the authenticity and exceptional quality of every TAF12S you purchase. Our commitment extends to providing secure and efficient worldwide delivery, ensuring that your essential instrumentation arrives safely at your facility, no matter where you are located. Trust tpt24 for reliability, quality, and unparalleled service for all your high-temperature measurement needs.

Optimized Costs, Increased Plant Safety

The TAF12S contributes to optimized costs and increased plant safety. Its long-lasting performance, stemming from advanced ceramic protection and resistance to harsh conditions, minimizes maintenance needs and replacement frequency. This leads to significant savings in operational expenses. Furthermore, by ensuring stable and accurate temperature readings, the TAF12S plays a crucial role in preventing process deviations that could lead to safety hazards, thereby increasing overall plant safety and operational reliability in demanding industrial environments.

Specifications

  • Measuring principle

    Thermocouple

  • Characteristic / Application

    metric style
    modular temperature assembly
    high temperature (furnace)
    incl. single ceramic thermowell

  • Thermowell / protection tube

    ceramic protection tube

  • Insert / probe

    ceramic capilarry, rigid

  • Outer diameter protection tube / Insert

    9,0 mm (0,35”)

  • Max. immersion length on request

    up to 2.500,00 mm (98,43”)

  • Material protection tube/ thermowell

    Ceramic (C610/C799)

  • Process connection

    compression fitting:
    G1/2″
    G3/4″
    G1″
    adjustable Flange

  • Tip shape

    straight

  • Operating temperature range

    Type S:
    0 °C …1.600 °C
    (32 °F …2.912 °F)
    Type R:
    0° C …1.600 °C
    (32 °F …2.912 °F)
    Type B:
    600 °C …1.700 °C
    (1.112 °F …3.092 °F)

  • Max. process pressure (static)

    at 20 °C: 1 bar (15 psi)

  • Accuracy

    class 2 acc. to IEC 60584

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    SIL (transmitter only)

Data Sheet