  • Measuring Principle: Thermocouple
  • Protection Tube: Triple Ceramic
  • Max Temp: +1,700 °C
  • Application: Furnace Measurement

Did you like this product? Add to favorites now and follow the product.

Add to wishlist
Have a Question? Ask a Specialist

(+86) 132-6243-8118 Start Live Chat

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Description

Endress+Hauser TAF12T: Ultimate Triple Ceramic Protection

The Endress+Hauser TAF12T: Ultimate Triple Ceramic Protection assembly is engineered for the most extreme high-temperature environments, surpassing even robust dual-layer designs. This exceptional instrument features triple ceramic protection tubes, offering unparalleled defense against mechanical stress and chemical corrosion. It is specifically developed for demanding applications within ceramic baking ovens, brickworks, porcelain production, and the glass industries, ensuring the integrity and accuracy of temperature measurements at levels up to +1700 °C (+3092 °F), thereby enhancing product quality and operational safety.

Extreme Temperature Applications Realized Safely

The TAF12T enables extreme temperature applications realized safely. Its unique triple ceramic sheath system provides superior protection for the precious metal thermocouples (like Types S, R, and B) used within. This enhanced shielding is crucial for processes operating at temperatures up to 1700 °C, such as specialized glass manufacturing or advanced ceramic firing cycles. By minimizing the risk of sensor damage from chemical attack or physical stress, the TAF12T significantly extends the lifespan of the measuring points, reducing downtime and maintenance costs.

Enhanced Durability with Triple Ceramic Layers

Experience enhanced durability with triple ceramic layers that redefine reliability in high-temperature sensing. The TAF12T incorporates not only a primary ceramic thermowell but also two additional inner ceramic tubes. This multi-layered protection system offers exceptional resistance to wear, thermal shock, and corrosive process media. The non-porous nature of these advanced ceramic materials ensures long-term stable measurements by preventing contaminants from reaching the sensitive thermocouple insert, a critical factor for consistent product quality.

Maximizing Sensor Lifespan and Performance

The TAF12T is designed for maximizing sensor lifespan and performance. By providing superior protection against harsh process conditions, the triple ceramic construction dramatically increases the operational life of the internal thermocouple sensors. This durability translates directly into significant cost savings, as the need for frequent replacements and maintenance is substantially reduced. The modular design further optimizes life cycle costs, allowing for the efficient replacement of individual spare parts rather than the entire assembly.

Versatile Metric Assembly for Furnaces

This instrument offers a versatile metric assembly for furnaces across various industries. The TAF12T is a modular temperature assembly ideal for high-temperature furnace applications. It can be configured with either a single or double thermocouple insert, encased in ceramic insulators. The outer diameter of the protection tubes is available in sizes like 24.0 mm and 26.0 mm, with a maximum immersion length of up to 3,500 mm available upon request. Process connections, such as G1 1/2″ compression fittings, ensure secure and adaptable installation.

Precision Measurement Across Types S, R, B

Achieve precision measurement across Types S, R, B thermocouples with the TAF12T. This advanced assembly is optimized to work seamlessly with these high-temperature sensing elements. Type S and R thermocouples can accurately measure temperatures from 0 °C up to 1600 °C, while Type B is suitable for the extreme range of 600 °C to 1700 °C. This capability makes the TAF12T indispensable for critical processes in the ceramics and glass industries where exact temperature control is paramount for product integrity and performance.

tpt24: Your Premier Global Source

For the Endress+Hauser TAF12T, tpt24: your premier global source, represents the pinnacle of online procurement for industrial instrumentation. We are unwavering in our commitment to guaranteeing the authenticity and superior quality of every TAF12T unit. Our robust worldwide delivery network ensures that your essential equipment reaches you securely and efficiently, no matter your global location. Rely on tpt24 for unparalleled service and the assurance of genuine, high-performance products for your most demanding industrial applications.

Reliable Operation at High Pressure

The TAF12T ensures reliable operation at high pressure conditions, maintaining its integrity even under demanding process loads. With a maximum static process pressure rating of 1 bar (15 psi) at 20 °C, combined with its robust triple ceramic construction, it offers dependable performance. Accuracy is maintained to Class 2 according to IEC 60584 standards, ensuring that measurements are precise and reliable. Optional integration with head transmitters supporting HART, PROFIBUS PA, and FOUNDATION FIELDBUS further enhances its utility and data management capabilities.

Specifications

  • Measuring principle

    Thermocouple

  • Characteristic / Application

    metric style
    modular temperature assembly
    high temperature (furnace)
    ncl. triple ceramic thermowell

  • Thermowell / protection tube

    ceramic protection tube and 2x inner tube

  • Insert / probe

    ceramic capilarry, rigid

  • Outer diameter protection tube / Insert

    24,0 mm (0,94″)
    26,0 mm (1,02″)

  • Max. immersion length on request

    up to 3.500,00 mm (137,80”)

  • Material protection tube/ thermowell

    Ceramic (C530/C610/C799)

  • Process connection

    compression fitting:
    G11/2″

  • Tip shape

    straight

  • Operating temperature range

    Type S:
    0 °C …1.600 °C
    (32 °F …2.912 °F)
    Type R:
    0 °C …1.600 °C
    (32 °F …2.912 °F)
    Type B:
    600 °C …1.700 °C
    (1.112 °F …3.092 °F)

  • Max. process pressure (static)

    at 20 °C: 1 bar (15 psi)

  • Accuracy

    class 2 acc. to IEC 60584

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    SIL (transmitter only)

Data Sheet

Download Data Sheet Of:Endress+Hauser TAF12T iTHERM FlameLine High temperature thermometer