Endress+Hauser TMT188 iTEMP temperature transmitter
- Input: Thermocouple (TC)
- Output: 4-20 mA
- Installation: Terminal head
- Approvals: ATEX, FM, CSA
Did you like this product? Add to favorites now and follow the product.
(+86) 132-6243-8118 Start Live Chat
Description
Endress+Hauser TMT188: TC Head-Mount Transmitter
The Endress+Hauser TMT188: TC Head-Mount Transmitter is specifically engineered to transform thermocouple (TC) sensor signals within a fixed measuring range. It provides a standardized 4 to 20 mA output signal, ensuring rapid, easy, and cost-effective temperature measurement. This transmitter delivers reliable and precise values essential for a wide array of industry applications, making it a highly versatile tool for critical process monitoring and control.
Converting TC Input to 4-20 mA Output
This fixed-range temperature transmitter focuses on converting TC input to 4-20 mA output, translating thermocouple signals into a scalable 4 to 20 mA analog output. This seamless conversion process is vital for integration into sophisticated industrial control systems, offering dependable and accurate temperature data. Its design prioritizes efficiency and reliability in demanding operational environments.
Fast, Easy, Cost-Effective Temperature Measuring
The TMT188 provides fast, easy, cost-effective temperature measuring, simplifying the acquisition of temperature data. It guarantees reliable and precise measurements suitable for a broad spectrum of industrial applications, reducing operational complexity and costs. This transmitter is an excellent choice for optimizing efficiency and ensuring accurate temperature monitoring across various processes.
High Accuracy Across Ambient Temperature Range
Achieve high accuracy across ambient temperature range with the TMT188, designed to maintain precision even under varying environmental conditions. Its robust performance ensures reliable data for critical processes, minimizing deviations and enhancing operational efficiency. The transmitter’s stability makes it a trusted component in demanding industrial settings requiring consistent, high-quality measurements.
Benefits: NAMUR Compliance, EMC Excellence
The TMT188 offers significant benefits: NAMUR compliance, EMC excellence. It provides failure information for sensor breaks or short circuits as per NAMUR NE 43, enhancing diagnostic capabilities. Furthermore, it meets NAMUR NE 21 and CE standards for EMC, ensuring robust performance against electromagnetic interference. These features underscore its reliability and suitability for critical applications.
Ex-Approval, Dust Zone, Marine Approval
With Ex-approval, dust zone, marine approval, the TMT188 ensures versatile and safe operation. It holds ATEX Ex ia approval for hazardous areas and dust zone 22 compliance (EN 50281-1), alongside FM IS and CSA IS certifications. The UL recognized component status and marine approval (GL) further confirm its adaptability and safety for deployment in diverse and challenging industrial and maritime environments.
TPT24: Your Premier Global Destination
For the Endress+Hauser TMT188, trust TPT24: Your Premier Global Destination. tpt24 stands as the world’s leading online store for this indispensable temperature transmitter. We guarantee the authenticity and quality of every product, offering secure and prompt worldwide delivery. Regardless of your location, tpt24 ensures you receive your TMT188 with confidence and complete satisfaction.
Applications: Critical Processes, Hazardous Zones
The TMT188 is ideal for applications: Critical processes, hazardous zones, efficiently transforming TC sensor signals for precise temperature monitoring. Its certifications for hazardous areas (ATEX, FM, CSA) and dust zones make it exceptionally suitable for industries like chemical processing, oil and gas, and manufacturing where safety and reliability are paramount. The marine approval further broadens its applicability.
Specifications
-
Measuring principle
Head transmitter
-
Input
1 x TC
-
Output
1 x analog 4…20 mA
-
Auxiliary power supply
8…35 V DC (standard-version)
8…30 V DC (Ex-version) -
Installation
Terminal head form B
-
Accuracy
(Type K) <= 0,5 K
(Type K) <= 0,9 °F -
Galvanic isolation
yes
-
Certification
UL Ex IS
UL Ex NI
GOST Ex i
GL marine approval
GOST Metrology
GL (German Lloyd)
ATEX EEx ia, Ex nA, Ex tc, Ex ia
CSA IS, NI
CSA General Purpose
FM IS, NI
FM+CSA IS, NI
EAC Ex ia